Journal list menu
Export Citations
Download PDFs
COVER IMAGE
Iterative static field map estimation for off-resonance correction in non-Cartesian susceptibility weighted imaging
- Page: C1
- First Published: 28 July 2022
ISSUE INFORMATION
EDITORIAL
On the open-source landscape of Magnetic Resonance in Medicine
- Pages: 1495-1497
- First Published: 28 July 2022
Click here for author-reader discussions
ANNOUNCEMENT
RESEARCH ARTICLES–SPECTROSCOPIC METHODOLOGY
Improved signal-to-noise performance of MultiNet GRAPPA 1H FID MRSI reconstruction with semi-synthetic calibration data
- Pages: 1500-1515
- First Published: 03 June 2022
Click here for author-reader discussions
Metabolite-cycled echo-planar spectroscopic imaging of the human heart
- Pages: 1516-1527
- First Published: 06 June 2022
Click here for author-reader discussions
GUIDELINES–IMAGING METHODOLOGY
Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation
- Pages: 1528-1547
- First Published: 12 July 2022
Click here for author-reader discussions
RESEARCH ARTICLES–IMAGING METHODOLOGY
Deep learning–based quantitative susceptibility mapping (QSM) in the presence of fat using synthetically generated multi-echo phase training data
- Pages: 1548-1560
- First Published: 17 June 2022
Click here for author-reader discussions
Cardio-respiratory motion-corrected 3D cardiac water-fat MRI using model-based image reconstruction
- Pages: 1561-1574
- First Published: 01 July 2022
Click here for author-reader discussions
Free-breathing motion-informed locally low-rank quantitative 3D myocardial perfusion imaging
- Pages: 1575-1591
- First Published: 17 June 2022
Click here for author-reader discussions
Iterative static field map estimation for off-resonance correction in non-Cartesian susceptibility weighted imaging
- Pages: 1592-1607
- First Published: 23 June 2022
Click here for author-reader discussions
Development of a novel 10-echo multi-contrast sequence based on EPIK to deliver simultaneous quantification of T2 and T2* with application to oxygen extraction fraction
- Pages: 1608-1623
- First Published: 03 June 2022
Click here for author-reader discussions
A probabilistic Bayesian approach to recover map and phase images for quantitative susceptibility mapping
- Pages: 1624-1642
- First Published: 07 June 2022
Click here for author-reader discussions
Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications
- Pages: 1643-1658
- First Published: 26 June 2022
Click here for author-reader discussions
OSCILLATE: A low-rank approach for accelerated magnetic resonance elastography
- Pages: 1659-1672
- First Published: 01 June 2022
Click here for author-reader discussions
Improving in situ acoustic intensity estimates using MR acoustic radiation force imaging in combination with multifrequency MR elastography
- Pages: 1673-1689
- First Published: 28 June 2022
Click here for author-reader discussions
Gradient-echo-train-based sub-millisecond periodic event encoded dynamic imaging with random (k, t)-space undersampling: k-t get-SPEEDI
- Pages: 1690-1701
- First Published: 06 June 2022
Click here for author-reader discussions
Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
- Pages: 1702-1719
- First Published: 12 June 2022
Click here for author-reader discussions
Quantification of changes in myocardial T1* values with exercise cardiac MRI using a free-breathing non-electrocardiograph radial imaging
- Pages: 1720-1733
- First Published: 12 June 2022
Click here for author-reader discussions
Accelerated fatty acid composition MRI of epicardial adipose tissue: Development and application to eplerenone treatment in a mouse model of obesity-induced coronary microvascular disease
- Pages: 1734-1747
- First Published: 20 June 2022
Click here for author-reader discussions
Free-breathing, non-ECG, simultaneous myocardial T1, T2, T2*, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking
- Pages: 1748-1763
- First Published: 17 June 2022
Click here for author-reader discussions
TECHNICAL NOTES–IMAGING METHODOLOGY
Phase-cycled balanced SSFP imaging for non-contrast-enhanced functional lung imaging
- Pages: 1764-1774
- First Published: 24 May 2022
Click here for author-reader discussions
EPI phase error correction with deep learning (PEC-DL) at 7 T
- Pages: 1775-1784
- First Published: 13 June 2022
Click here for author-reader discussions
Accelerating Brain Imaging Using a Silent Spatial Encoding Axis
- Pages: 1785-1793
- First Published: 13 June 2022
Click here for author-reader discussions
RESEARCH ARTICLES–PRECLINICAL AND CLINICAL IMAGING
Point-of-care magnetic resonance technology to measure liver fat: Phantom and first-in-human pilot study
- Pages: 1794-1805
- First Published: 25 May 2022
Click here for author-reader discussions
Correcting for imaging gradients–related bias of T2 relaxation times at high-resolution MRI
- Pages: 1806-1817
- First Published: 06 June 2022
Click here for author-reader discussions
TECHNICAL NOTE–PRECLINICAL AND CLINICAL IMAGING
Multicenter Repeatability and Reproducibility of MR Fingerprinting in Phantoms and in Prostatic Tissue
- Pages: 1818-1827
- First Published: 17 June 2022
Click here for author-reader discussions
RESEARCH ARTICLES–BIOPHYSICS AND BASIC BIOMEDICAL RESEARCH
Characterization and correction of the effects of hepatic iron on T1ρ relaxation in the liver at 3.0T
- Pages: 1828-1839
- First Published: 24 May 2022
Click here for author-reader discussions
Comparison of inversion methods in MR elastography: An open-access pipeline for processing multifrequency shear-wave data and demonstration in a phantom, human kidneys, and brain
- Pages: 1840-1850
- First Published: 12 June 2022
Click here for author-reader discussions
RESEARCH ARTICLES–COMPUTER PROCESSING AND MODELING
Accelerating multi-echo chemical shift encoded water–fat MRI using model-guided deep learning
- Pages: 1851-1866
- First Published: 01 June 2022
Click here for author-reader discussions
Modeling the Effect of Hyperoxia on the Spin–Lattice Relaxation Rate R1 of Tissues
- Pages: 1867-1885
- First Published: 09 June 2022
Click here for author-reader discussions
RESEARCH ARTICLES–HARDWARE AND INSTRUMENTATION
Development of a novel MR-conditional microwave needle for MR-guided interventional microwave ablation at 1.5T
- Pages: 1886-1900
- First Published: 01 July 2022
Click here for author-reader discussions
Systematic Dimensional Analysis of the Scaling Relationship for Gradient and Shim Coil Design Parameters
- Pages: 1901-1911
- First Published: 06 June 2022
Click here for author-reader discussions
A 32-element loop/dipole hybrid array for human head imaging at 7 T
- Pages: 1912-1926
- First Published: 29 June 2022
Click here for author-reader discussions
TECHNICAL NOTES–HARDWARE AND INSTRUMENTATION
Compact MR-compatible ergometer and its application in cardiac MR under exercise stress: A preliminary study
- Pages: 1927-1936
- First Published: 01 June 2022
Click here for author-reader discussions
Direct comparison of gradient Fidelity and acoustic noise of the same MRI system at 3 T and 0.75 T
- Pages: 1937-1947
- First Published: 01 June 2022
Click here for author-reader discussions