Volume 13, Issue 2 e201960127
FULL ARTICLE

Acoustic resolution photoacoustic microscopy based on microelectromechanical systems scanner

Mohesh Moothanchery

Mohesh Moothanchery

Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore

Search for more papers by this author
Kapil Dev

Kapil Dev

Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore

Search for more papers by this author
Ghayathri Balasundaram

Ghayathri Balasundaram

Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore

Search for more papers by this author
Renzhe Bi

Renzhe Bi

Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore

Search for more papers by this author
Malini Olivo

Corresponding Author

Malini Olivo

Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore

Correspondence

Malini Olivo, Laboratory of Bio-Optical Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A*STAR), Singapore, Singapore.

Email: [email protected];

Search for more papers by this author
First published: 04 November 2019
Citations: 14

Funding information: Singapore Bioimaging Consortium, ASTAR, Grant/Award Number: Intramural funding; Biomedical Research Council

Abstract

Photoacoustic microscopy (PAM) can be classified as optical resolution (OR)-PAM and acoustic resolution (AR)-PAM depending on the type of resolution achieved. Using microelectromechanical systems (MEMS) scanner, high-speed OR-PAM system was developed earlier. Depth of imaging limits the use of OR-PAM technology for many preclinical and clinical imaging applications. Here, we demonstrate the use of a high-speed MEMS scanner for AR-PAM imaging. Lateral resolution of 84 μm and an axial resolution of 27 μm with ~2.7 mm imaging depth was achieved using a 50 MHz transducer-based AR-PAM system. Use of a higher frequency transducer at 75 MHz has further improved the resolution characteristics of the system with a reduction in imaging depth and a lateral resolution of 53 μm and an axial resolution of 18 μm with ~1.8 mm imaging depth was achieved. Using the two-axis MEMS scanner a 2 × 2 .5 mm2 area was imaged in 3 seconds. The capability of achieving acoustic resolution images using the MEMS scanner makes it beneficial for the development of high-speed miniaturized systems for deeper tissue imaging.

image

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.