Volume 10, Issue 8 pp. 1074-1079
Full Article

Raman spectroscopy and PCA-SVM as a non-invasive diagnostic tool to identify and classify qualitatively glycated hemoglobin levels in vivo

J. F. Villa-Manríquez

Corresponding Author

J. F. Villa-Manríquez

Instituto Nacional de Astrofísica Óptica y Electrónica, apartado postal 51 y 216, Tonantzintla, Puebla, CP 72000 México

Corresponding author: e-mail: [email protected]

Search for more papers by this author
J. Castro-Ramos

J. Castro-Ramos

Instituto Nacional de Astrofísica Óptica y Electrónica, apartado postal 51 y 216, Tonantzintla, Puebla, CP 72000 México

Search for more papers by this author
F. Gutiérrez-Delgado

F. Gutiérrez-Delgado

Centro de Estudios y Prevención del Cáncer, Bugambilias 30, Fraccionamiento la Rivera, Juchitan, Oaxaca, CP 70020 México

Search for more papers by this author
M. A. Lopéz-Pacheco

M. A. Lopéz-Pacheco

Instituto Nacional de Astrofísica Óptica y Electrónica, apartado postal 51 y 216, Tonantzintla, Puebla, CP 72000 México

Search for more papers by this author
A. E. Villanueva-Luna

A. E. Villanueva-Luna

Universidad Tecnológica de Campeche, Carretera Federal 180 S/N, San Antonio Cárdenas, Carmen, Campeche, CP 24100 México

Search for more papers by this author
First published: 23 December 2016
Citations: 29

Abstract

In this study we identify and classify high and low levels of glycated hemoglobin (HbA1c) in healthy volunteers (HV) and diabetic patients (DP). Overall, 86 subjects were evaluated. The Raman spectrum was measured in three anatomical regions of the body: index fingertip, right ear lobe, and forehead. The measurements were performed to compare the difference between the HV and DP (22 well controlled diabetic patients (WCDP) (HbA1c <6.5%), and 49 not controlled diabetic patients (NCDP) (HbA1c ≥6.5%)). Multivariable methods such as principal components analysis (PCA) combined with support vector machine (SVM) were used to develop effective diagnostic algorithms for classification among these groups. The forehead of HV versus WCDP showed the highest sensitivity (100%) and specificity (100%). Sensitivity (100%) and specificity (60%), were highest in the forehead of WCDP, versus NCDP. In HV versus NCDP, the fingertip had the highest sensitivity (100%) and specificity (80%). The efficacy of the diagnostic algorithm by receiver operating characteristic (ROC) curve was confirmed. Overall, our study demonstrated that the

figure

combination of Raman spectroscopy and PCA-SVM are feasible non-invasive diagnostic tool in diabetes to classify qualitatively high and low levels of HbA1c in vivo.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.