Journal list menu
Export Citations
Download PDFs
research papers
Harmonic radiation contribution and X-ray transmission at the Small Quantum Systems instrument of European XFEL
- Pages: 662-670
- First Published: 10 May 2023
A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell
- Pages: 671-685
- First Published: 15 June 2023
Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs
- Pages: 686-694
- First Published: 15 June 2023

The thermal deformation requirement for wavefront preservation through an X-ray crystal monochromator is found to restrict the standard deviation of the height error to less than 25 pm under certain conditions. By optimizing the effective cooling temperature of liquid-nitrogen-cooled crystals, combined with compensation of the second-order component of the thermal deformation, an approach to reach this unprecedented requirement is described.
Development of a custom-made 2.8 T permanent-magnet dipole photon source for the ROCK beamline at SOLEIL
- Pages: 695-707
- First Published: 10 May 2023

Since August 2021, the French synchrotron light source SOLEIL has been running with a 1 m-long permanent-magnet dipole producing a magnetic field of 2.8 T. This is a major modification of the storage ring that allows the high-energy photon flux for the ROCK beamline to be increased and significantly improves the resolution for experiments performed above 20 keV.
X-ray mirrors with sub-nanometre figure errors obtained by differential deposition of thin WSi2 films
- Pages: 708-716
- First Published: 31 May 2023
A compact gas attenuator for the SwissFEL ATHOS beamline realized using additive manufacturing
- Pages: 717-722
- First Published: 31 May 2023
EIGER2 hybrid-photon-counting X-ray detectors for advanced synchrotron diffraction experiments
- Pages: 723-738
- First Published: 21 June 2023
Analysis of the dislocation activity of Mg–Zn–Y alloy using synchrotron radiation under tensile loading
- Pages: 739-745
- First Published: 11 May 2023

The convolutional multiple whole profile fitting method of X-ray line profile analysis using synchrotron radiation allows the experimental determination of dislocation densities separately for different Burgers vectors up to a high degree of deformation. Its reliability for Mg–Zn–Y alloys, in terms of the dislocation activity during tensile deformation, has been successfully verified by combined analysis with electron backscatter diffraction investigation and visco-plastic self-consistent simulation.
Soft X-ray spectro-ptychography of boron nitride nanobamboos, carbon nanotubes and permalloy nanorods
- Pages: 746-757
- First Published: 05 May 2023
Phase segregation and miscibility of TiOx nanocomposites in Gd-doped ceria solid electrolyte material
- Pages: 758-765
- First Published: 30 May 2023

The local structure of titania–ceria composites in a Gd-doped ceria solid electrolyte material is obtained by a combination of X-ray absorption fine structure and X-ray diffraction over the entire range of Ti composition. A compositional region (between 19 and 57%) with strongly distorted TiO6 units and coexistence of Ce(III) and Ce(IV) was discovered, i.e. optimized for oxygen transport conduction and in agreement with the enhanced electro-chemo-mechanical effect previously observed in this composition range.
Quantitative alignment parameter estimation for analyzing X-ray photoelectron spectra
- Pages: 766-779
- First Published: 16 June 2023

A model of an X-ray photoelectron spectroscopy experiment accounting for photon beam asperities, sample geometry and kinetic energy analyzer is introduced. This model is related via the alignment parameter to a simple model commonly used for data interpretation. An alignment parameter estimation method is introduced and tested with simulated and experimental data.
Translocation and fate of nanospheres in pheochromocytoma cells following exposure to synchrotron-sourced terahertz radiation
- Pages: 780-787
- First Published: 20 June 2023
Micropipette aspiration as a tool for single-particle X-ray imaging and diffraction
- Pages: 788-795
- First Published: 30 May 2023

Micropipette aspiration has been combined with a windowless hydrated sample environment for single-particle X-ray analysis. A water droplet serves as a `chamber', covered by a mineral oil to prevent evaporation. In the droplet, particles can be aspirated and manipulated by one or two micropipettes. The system was evaluated on two undulator beamlines, using grains, giant lipid vesicles, colloids and macrophages as test objects. Holographic near-field images were recorded.
Mapping nanocrystal orientations via scanning Laue diffraction microscopy for multi-peak Bragg coherent diffraction imaging
- Pages: 796-806
- First Published: 31 May 2023
short communications
Towards joint in situ determination of pressure and temperature in the large volume press exclusively from X-ray diffraction
- Pages: 807-814
- First Published: 21 June 2023

Research in high-pressure devices, such as the diamond anvil cell and the large volume press, requires knowledge of the pressure and temperature in the sample. Here, a large volume press and an internal resistive heater were used to generate high load and heat to various combinations of intimately mixed powders of materials. X-ray diffraction and custom software were used to jointly estimate the pressures and temperatures in the samples and establish calibrants for in situ experiments at extreme conditions.
beamlines
Full-field hard X-ray nano-tomography at SSRF
- Pages: 815-821
- First Published: 05 May 2023
A von Hámos spectrometer for diamond anvil cell experiments at the High Energy Density Instrument of the European X-ray Free-Electron Laser
- Pages: 822-830
- First Published: 09 May 2023
FlexPES: a versatile soft X-ray beamline at MAX IV Laboratory
- Pages: 831-840
- First Published: 09 May 2023
High-pressure single-crystal diffraction at the Australian Synchrotron
- Pages: 841-846
- First Published: 15 June 2023
Soft X-ray beamline BL1N2 at Aichi Synchrotron Radiation Center and its industrial use
- Pages: 847-854
- First Published: 20 June 2023
addenda and errata
In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination. Corrigendum
- Page: 855
- First Published: 30 May 2023

Corrigendum to the article by Weng et al. (2023) [J. Synchrotron Rad.30, 546–554].