Quantification and visualization of flow in the Circle of Willis: Time-resolved three-dimensional phase contrast MRI at 7 T compared with 3 T
Corresponding Author
P. van Ooij
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
Department of Radiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands===Search for more papers by this authorJ. J. M. Zwanenburg
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorF. Visser
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorC. B. Majoie
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorE. vanBavel
Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorJ. Hendrikse
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorA. J. Nederveen
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorCorresponding Author
P. van Ooij
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
Department of Radiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands===Search for more papers by this authorJ. J. M. Zwanenburg
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorF. Visser
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorC. B. Majoie
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorE. vanBavel
Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorJ. Hendrikse
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
Search for more papers by this authorA. J. Nederveen
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
Search for more papers by this authorAbstract
The assessment of both geometry and hemodynamics of the intracranial arteries has important diagnostic value in internal carotid occlusion, sickle cell disease, and aneurysm development. Provided that signal to noise ratio (SNR) and resolution are high, these factors can be measured with time-resolved three-dimensional phase contrast MRI. However, within a given scan time duration, an increase in resolution causes a decrease in SNR and vice versa, hampering flow quantification and visualization. To study the benefits of higher SNR at 7 T, three-dimensional phase contrast MRI in the Circle of Willis was performed at 3 T and 7 T in five volunteers. Results showed that the SNR at 7 T was roughly 2.6 times higher than at 3 T. Therefore, segmentation of small vessels such as the anterior and posterior communicating arteries succeeded more frequently at 7 T. Direction of flow and smoothness of streamlines in the anterior and posterior communicating arteries were more pronounced at 7 T. Mean velocity magnitude values in the vessels of the Circle of Willis were higher at 3 T due to noise compared to 7 T. Likewise, areas of the vessels were lower at 3 T. In conclusion, the gain in SNR at 7 T compared to 3 T allows for improved flow visualization and quantification in intracranial arteries. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
REFERENCES
- 1 Lee RMKW. Morphology of cerebral arteries. Pharmacol Ther 1995; 66: 149–173.
- 2 Hendrikse J, Hartkamp MJ, Hillen B, Mali WP, van der Grond J. Collateral ability of the circle of Willis in patients with unilateral internal carotid artery occlusion: border zone infarcts and clinical symptoms. Stroke 2001; 32: 2768–2773.
- 3 Gevers S, Nederveen AJ, Fijnvandraat K, van den Berg SM, van Ooij P, Heijtel DF, Heijboer H, Nederkoorn PJ, Engelen M, van Osch MJ, Majoie CB. Arterial spin labeling measurement of cerebral perfusion in children with sickle cell disease. J Magn Reson Imaging 2012; 35: 779–787.
- 4 Brisman JL, Song JK, Newell DW. Cerebral aneurysms. N Engl J Med 2006; 355: 928–939.
- 5 Bor AS, Velthuis BK, Majoie CB, Rinkel GJ. Configuration of intracranial arteries and development of aneurysms: a follow-up study. Neurology 2008; 70: 700–705.
- 6 de Rooij NK, Velthuis BK, Algra A, Rinkel GJ. Configuration of the circle of Willis, direction of flow, and shape of the aneurysm as risk factors for rupture of intracranial aneurysms. J Neurol 2009; 256: 45–50.
- 7 Kayembe KN, Sasahara M, Hazama F. Cerebral aneurysms and variations in the circle of Willis. Stroke 1984; 15: 846–850.
- 8 Sforza DM, Putman CM, Cebral JR. Hemodynamics of cerebral aneurysms. Annu Rev Fluid Mech 2009; 41: 91–107.
- 9 Wang WC, Gallagher DM, Pegelow CH, Wright EC, Vichinsky EP, Abboud MR, Moser FG, Adams RJ. Multicenter comparison of magnetic resonance imaging and transcranial Doppler ultrasonography in the evaluation of the central nervous system in children with sickle cell disease. J Pediatr Hematol Oncol 2000; 22: 335–339.
- 10 Baharoglu MI, Schirmer CM, Hoit DA, Gao BL, Malek AM. Aneurysm inflow-angle as a discriminant for rupture in sidewall cerebral aneurysms: morphometric and computational fluid dynamic analysis. Stroke 2010; 41: 1423–1430.
- 11 Ingebrigtsen T, Morgan MK, Faulder K, Ingebrigtsen L, Sparr T, Schirmer H. Bifurcation geometry and the presence of cerebral artery aneurysms. J Neurosurg 2004; 101: 108–113.
- 12 Alnaes MS, Isaksen J, Mardal KA, Romner B, Morgan MK, Ingebrigtsen T. Computation of hemodynamics in the circle of Willis. Stroke 2007; 38: 2500–2505.
- 13 Cebral JR, Castro MA, Soto O, Löhner R, Alperin N. Blood-flow models of the circle of Willis from magnetic resonance data. J Eng Math 2003; 47: 369–386.
- 14 Alastruey J, Parker KH, Peiro J, Byrd SM, Sherwin SJ. Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. J Biomech 2007; 40: 1794–1805.
- 15 Enzmann DR, Ross MR, Marks MP, Pelc NJ. Blood flow in major cerebral arteries measured by phase-contrast cine MR. AJNR Am J Neuroradiol 1994; 15: 123–129.
- 16 Chien A, Castro MA, Tateshima S, Sayre J, Cebral J, Vinuela F. Quantitative hemodynamic analysis of brain aneurysms at different locations. AJNR Am J Neuroradiol 2009; 30: 1507–1512.
- 17 Markl M, Chan FP, Alley MT, Wedding KL, Draney MT, Elkins CJ, Parker DW, Wicker R, Taylor CA, Herfkens RJ, Pelc NJ. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2003; 17: 499–506.
- 18 Wigstrom L, Sjoqvist L, Wranne B. Temporally resolved 3D phase-contrast imaging. Magn Reson Med 1996; 36: 800–803.
- 19 Yamashita S, Isoda H, Hirano M, Takeda H, Inagawa S, Takehara Y, Alley MT, Markl M, Pelc NJ, Sakahara H. Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2007; 25: 473–478.
- 20 Wetzel S, Meckel S, Frydrychowicz A, Bonati L, Radue EW, Scheffler K, Hennig J, Markl M. In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T. AJNR Am J Neuroradiol 2007; 28: 433–438.
- 21 Bammer R, Hope TA, Aksoy M, Alley MT. Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging. Magn Reson Med 2007; 57: 127–140.
- 22 Gevers S, Heijtel D, Ferns SP, van Ooij P, van Rooij WJ, van Osch MJ, van den Berg R, Nederveen AJ, Majoie CB. Cerebral perfusion long term after therapeutic occlusion of the internal carotid artery in patients who tolerated angiographic balloon test occlusion. AJNR Am J Neuroradiol 2012; 33: 329–335.
- 23 Miralles M, Dolz JL, Cotillas J, Aldoma J, Santiso MA, Gimenez A, Capdevila A, Cairols MA. The role of the circle of Willis in carotid occlusion: assessment with phase contrast MR angiography and transcranial duplex. Eur J Vasc Endovasc Surg 1995; 10: 424–430.
- 24 Kluytmans M, van der Grond J, van Everdingen KJ, Klijn CJ, Kappelle LJ, Viergever MA. Cerebral hemodynamics in relation to patterns of collateral flow. Stroke 1999; 30: 1432–1439.
- 25 Hendrikse J, Klijn CJ, van Huffelen AC, Kappelle LJ, van der Grond J. Diagnosing cerebral collateral flow patterns: accuracy of non-invasive testing. Cerebrovasc Dis 2008; 25: 430–437.
- 26 Isoda H, Ohkura Y, Kosugi T, Hirano M, Alley MT, Bammer R, Pelc NJ, Namba H, Sakahara H. Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology 2010; 52: 913–920.
- 27 van Ooij P, Guédon A, Poelma C, Schneiders J, Rutten MCM, Marquering HA, Majoie CB, vanBavel E, Nederveen AJ. Complex flow patterns in a real-size intracranial aneurysm phantom: phase contrast MRI compared with particle image velocimetry and computational fluid dynamics. NMR Biomed 2012; 25: 14–26.
- 28 Boussel L, Rayz V, Martin A, Acevedo-Bolton G, Lawton MT, Higashida R, Smith WS, Young WL, Saloner D. Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics. Magn Reson Med 2009; 61: 409–417.
- 29 Kecskemeti S, Johnson K, Wu Y, Mistretta C, Turski P, Wieben O. High resolution three-dimensional cine phase contrast MRI of small intracranial aneurysms using a stack of stars k-space trajectory. J Magn Reson Imaging 2012; 35: 518–527.
- 30 Chang W, Kecskemeti S, Frydrychowicz A, Landgraf B, Aagaard-Kienitz B, Wu Y, Johnson K, Wieben O, Mistretta C, Turski P. Calculation of wall shear stress in intracranial cerebral aneurysms using high resolution phase contrast MRA (PC-VIPR). In Proceedings of the 10th Annual Meeting of ISMRM, Montreal, Canada, 2011. p. 3307.
- 31 Castro MA, Putman CM, Cebral JR. Patient-specific computational fluid dynamics modeling of anterior communicating artery aneurysms: a study of the sensitivity of intra-aneurysmal flow patterns to flow conditions in the carotid arteries. AJNR Am J Neuroradiol 2006; 27: 2061–2068.
- 32 Jou LD, Lee DH, Mawad ME. Cross-flow at the anterior communicating artery and its implication in cerebral aneurysm formation. J Biomech 2010; 43: 2189–2195.
- 33
Pruessmann KP,
Weiger M,
Scheidegger MB,
Boesiger P.
SENSE: sensitivity encoding for fast MRI.
Magn Reson Med
1999;
42:
952–962.
10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S CAS PubMed Web of Science® Google Scholar
- 34 Pelc NJ, Bernstein MA, Shimakawa A, Glover GH. Encoding strategies for three-direction phase-contrast MR imaging of flow. J Magn Reson Imaging 1991; 1: 405–413.
- 35 Lenz GW, Haacke EM, White RD. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Imaging 1989; 7: 445–455.
- 36 Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002; 22: 651–671.
- 37 Li C, Xu C, Gui C, Fox MD. Level set evolution without re-initialization: A new variational formulation. In IEEE Conference on Computer Vision and Pattern Recognotion (CVPR), 2005. p. 430–436.
- 38 Dumoulin CL, Souza SP, Walker MF, Wagle W. Three-dimensional phase contrast angiography. Magn Reson Med 1989; 9: 139–149.
- 39 Jenkinson M, Smith S. A global optimisation method for robust affine registration of brain images. Med Image Anal 2001; 5: 143–156.
- 40 Price RR, Axel L, Morgan T, Newman R, Perman W, Schneiders N, Selikson M, Wood M, SR Thomas. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1. Med Phys 1990; 17: 287–295.
- 41 Reeder SB, Wintersperger BJ, Dietrich O, Lanz T, Greiser A, Reiser MF, Glazer GM, Schoenberg SO. Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil. Magn Reson Med 2005; 54: 748–754.
- 42 Conturo TE, Smith GD. Signal-to-noise in phase angle reconstruction: dynamic range extension using phase reference offsets. Magn Reson Med 1990; 15: 420–437.
- 43 van Kooij BJ, Hendrikse J, Benders MJ, de Vries LS, Groenendaal F. Anatomy of the circle of Willis and blood flow in the brain-feeding vasculature in prematurely born infants. Neonatology 2010; 97: 235–241.
- 44 Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003; 50: 1031–1042.
- 45 Kim D, Dyvorne HA, Otazo R, Feng L, Sodickson DK, Lee VS. Accelerated phase-contrast cine MRI using k-t SPARSE-SENSE. Magn Reson Med 2012; 67: 1054–1064.
- 46 Carlsson M, Toger J, Kanski M, Markenroth Bloch K, Stahlberg F, Heiberg E, Arheden H. Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: Head to head comparison and validation at 1.5 T and 3 T. J Cardiovasc Magn Reson 2011; 13: 55.