Evaluating a smartwatch notification system in a simulated nursing home
Corresponding Author
Haneen Ali PhD
Assistant Professor
Auburn University, Auburn, Alabama
Correspondece
Haneen Ali, Industrial and Systems Engineer, Health Services Administration Program, Auburn University, Auburn, AL 36849.
Email: [email protected]
Search for more papers by this authorHuiyang Li PhD
Assistant Professor
State University of New York at Binghamton, Binghamton, New York
Search for more papers by this authorCorresponding Author
Haneen Ali PhD
Assistant Professor
Auburn University, Auburn, Alabama
Correspondece
Haneen Ali, Industrial and Systems Engineer, Health Services Administration Program, Auburn University, Auburn, AL 36849.
Email: [email protected]
Search for more papers by this authorHuiyang Li PhD
Assistant Professor
State University of New York at Binghamton, Binghamton, New York
Search for more papers by this authorAbstract
Aims
This paper evaluates a high-fidelity prototype of a smartwatch-based communication system for nursing homes. The system could improve communication between residents and caregivers, thus reducing staff response time and improving residents' safety.
Background
Across the country, nursing homes are often cited as having serious quality and safety issues. Deficiencies in the communication systems that connect residents with caregivers significantly impact the quality of care. Most nursing homes still use traditional call light systems, that give visual and auditory cues to caregivers, who may or may not be in proximity to the system. This study evaluates a smartwatch communication system developed to quickly relay a resident's requests for assistance to staff anywhere in the nursing home.
Method
Certified Nursing Assistants (CNAs) employed by nursing homes were recruited to perform routine tasks using both a traditional system and a smart system. Response time to call lights, staff performance and outcomes were measured through direct and recorded observations and through the surveys of participants.
Results
The smartwatch system reduced staff response time to call lights from bedrooms by 40%, from bathrooms by 58% and from bed exit alarms by 29%. The smartwatch system also reduced perceived workload by about 50% and was highly accepted by the CNAs.
Conclusion
A smartwatch-based notification system may increase staff performance and decrease workload, thus leading to greater staff and patient satisfaction, which could ultimately lead to better quality of care and patient safety.
Relevance to clinical practice
This study provides empirical evidence for the usefulness of smartwatches in facilitating the notification and communication processes in healthcare settings and is also among the first to actually examine a smartwatch system in a healthcare setting.
Supporting Information
Filename | Description |
---|---|
opn12241-sup-0001-Questionnaire1.docxWord document, 19.5 KB | |
opn12241-sup-0002-Questionnaire2.docxWord document, 19.2 KB |
Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
REFERENCES
- Ahanathapillai, V., Amor, J. D., & James, C. J. (2015). Assistive technology to monitor activity, health, and wellbeing in old age: The wrist wearable unit in the USEFIL project. Technology and Disability, 27(1,2), 17–29. https://doi.org/10.3233/TAD-150425
10.3233/TAD-150425 Google Scholar
- Aiken, L. H., & Patrician, P. A. (2000). Measuring organizational traits of hospitals: The revised nursing work index. Nursing Research, 49(3), 146–153.
- Ali, H., & Li, H. (2015). Developing a fall prevention system for nursing homes. Proceedings of the Human Factors and Ergonomics Society's 59th Annual Meeting. Los Angeles, CA: Human Factors and Ergonomics Society.
- Ali, H., & Li, H. (2016). Designing a smart watch interface of notification and communication systems for nursing homes. In J. Zhou, & G. Salvendy (Eds.), Human aspects of IT for the aged p opulation: Design for aging (Proceedings of the Second International Conference, ITAP 2016, Held as Part of HCI International 2016, Toronto, ON, Canada, July 17–22, 2016, Part I). LNCS 9747, 132–143. Switzerland: Springer International Publishing. LNCS 9754, 401–411.
10.1007/978-3-319-39943-0_39 Google Scholar
- Ali, H., Li, H., & Wong, J. (2017). Evaluating a smartwatch-based notification system in a simulated nursing home: The method. In Proceedings of the 2017 International Symposium on Human Factors and Ergonomics in Health Care. New Orleans, LA: Human Factors and Ergonomics Society
- Årsand, E., Muzny, M., Bradway, M., Muzik, J., & Hartvigsen, G. (2015). Performance of the first combined smartwatch and smartphone diabetes diary application study. Journal of Diabetes Science and Technology, 9(3), 556–563. https://doi.org/10.1177/1932296814567708
- Attree, M. (2001). Patients' and relatives' experiences and perspectives of ‘good' and ‘not so good' quality care. Journal of Advanced Nursing, 33, 456–466.
- Baldwin, C. (2012). Auditory Cognition and Human Performance: Research and Applications. Boca Raton, FL: CRC Press.
- Blayney, B. (2008). Diagnostic Images and Clinical Laboratory Results. Journal of Oncology Practice, 4(4), 210–211.
- Bradway, M., Årsand, E., & Grøttland, A. (2015). Mobile health: Empowering patients and driving change. Trends in Endocrinology & Metabolism, 26(3), 114–117.
- Broughton, W., Lashlee, H., Marcum, C., & Wilson, G. M. (2013). Health information technology: A new world of nursing homes. Gerontology & Geriatrics Research, 2(2), 1–6. https://doi.org/10.4172/2167-7182.1000122
10.4172/2167-7182.1000122 Google Scholar
- Carayon, P., & Gürses, A. P. (2005). A human factors engineering conceptual framework of nursing workload and patient safety in intensive care units. Intensive & Critical Care Nursing, 21(5), 284–301.
- Carayon, P., Hundt, A. S., Karsh, B., Gurses, A. P., Alvarado, C. J., Smith, M., & Brennan, P. F. (2006). Work system design for patient safety: The SEIPS model. Quality & Safety in Health Care, 15(Suppl 1), i50–i58. https://doi.org/10.1136/qshc.2005.015842
- Carayon, P., Xie, A., & Kianfar, S. (2014). Human factors and ergonomics as a patient safety practice. BMJ Quality & Safety, 23(3), 196–205. https://doi.org/10.1136/bmjqs-2013-001812
- Cardoso, G., & Martin, N. (2003). The patient connection: Improving call bell response at Cambridge Memorial Hospital. Healthcare Management Forum, 16(3), 47–50. https://doi.org/10.1016/S0840-4704(10)60235-9
10.1016/S0840-4704(10)60235-9 Google Scholar
- Carlson, J. D., Mittek, M., Parkison, S. A., Sathler, P., Bayne, D., Psota, E. T., …Bonasera, S. J. (2014). Smart watch RSSI localization and refinement for behavioral classification using laser-SLAM for mapping and fingerprinting. Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society, 2014, pp. 2173–2176.
- Casilari, E., & Oviedo-Jiménez, M. A. (2015). Automatic fall detection system based on the combined use of a smartphone and a smartwatch. PLoS ONE, 10(11), e0140929. https://doi.org/10.1371/journal.pone.0140929
- . Centers for Medicare and Medicaid Services. Nursing home compare. Retrieved from https://www.medicare.gov/nursinghomecompare/search.html
- Costas, B., McCallum, B., & Landmark, B. F. (2015). The use of smartwatches for health monitoring in home-based dementia care. Lecture Notes in Computer Science, 9194, 15–26.
10.1007/978-3-319-20913-5_2 Google Scholar
- Deitrick, L. D., Bokovoy, H., Stern, G., & Panik, A. (2006). Dance of the call bells: Using ethnography to evaluate patient satisfaction with quality of care. Journal of Nursing Care Quality, 21, 316–324.
- Deloris, J. (2014). Evidence based falls management program in the nursing home. Retrieved from http://scholarworks.bellarmine.edu/cgi/viewcontent.cgi?article=1008&context=tdc
- Dolan, B. (2015). Apple shows off AirStrip's vital sign monitoring Apple Watch app. Retrieved from http://www.mobihealthnews.com/46687/apple-shows-off-airstrips-vital-sign-monitoring-apple-watch-app
- Ernst, A. A., Weiss, S. J., & Reitsema, J. A. (2013). Does the addition of Vocera hands-free communication device improve interruptions in an academic emergency department? Southern Medical Journal, 106(3), 189–195. https://doi.org/10.1097/SMJ.0b013e318287faee
- Ferris, T. K., & Sarter, N. (2011). Continuously informing vibrotactile displays in support of attention management and multitasking in anesthesiology. Human Factors, 53(6), 600–611. https://doi.org/10.1177/0018720811425043
- Freedman, V., Calkins, M., DeRosier, R., & Haitsma, K. (2005). Barriers to implementing technology in residential long term care setting. Office of Disability, Aging and Long-Term Care Policy, U.S. Department of Health and Human Services. Retrieved from https://aspe.hhs.gov/sites/default/files/pdf/74506/techbarr.pdf
- Galinato, J., Montie, M., Patak, L., & Titler, M. (2015). Perspectives of Nurses and Patients on Call Light Technology. CIN. Computers, Informatics, Nursing, 33(8), 359–367.
- Holden, R. J., Scanlon, M. C., Patel, N. R., Kaushal, R., Escoto, K. H., Brown, R. L., … Karsh, B.-T. (2011). A human factors framework and study of the effect of nursing workload on patient safety and employee quality of working life. BMJ Quality & Safety, 20(1), 15–24. https://doi.org/10.1136/bmjqs.2008.028381
- Johnson, K. (2014). Literature Review: An investigation into the usefulness of the Smart Watch Interface for university students and the types of data they would require, Retrieved from http://img1.wikia.nocookie.net/__cb20140801120101/mobile-computing-prediction/images/c/c7/Literature_Review_KMJ.pdf
- Kalisch, B., Labelle, A. E., & Boqin, X. (2013). Nursing teamwork and time to respond to call lights: An exploratory study. Revista Latino-Americana De Enfermagem, 12(special), 242–249. https://doi.org/10.1590/S0104-11692013000700030
- Karsh, B. (2004). Beyond usability: Designing effective technology implementation systems to promote patient safety. Quality & Safety in Health Care, 13(5), 388–394. https://doi.org/10.1136/qshc.2004.010322
- Karsh, B., Holden, R. J., Alper, S. J., & Or, C. K. L. (2006). A human factors engineering paradigm for patient safety: Designing to support the performance of the healthcare professional. Quality & Safety in Health Care, 15(1), i59–i65. https://doi.org/10.1136/qshc.2005.015974
- Kuruzovich, J., Angst, C. M., Faraj, S., & Agarwal, R. (2008). Wireless communication role in patient response time: A study of vocera integration with a nurse call system. CIN. Computers, Informatics, Nursing, 26(3), 159–166.
- Lee, S., Kim, Y., Ahn, D., Ha, R., Lee, K., & Cha, H. (2015). Non-obstructive room-level locating system in home environments using activity fingerprints from smartwatch. In Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing, 2015, September 7–11; Osaka, Japan (pp. 939–950). New York, NY: ACM, 2015.
- Levinson, D. (2012). Gaps continue to exist in nursing home emergency preparedness and response during disasters: 2007–2010. Department of Health and Human Services, Office of Inspector General. Retrieved from http://ltcombudsman.org/uploads/files/library/oig-report.pdf
- Li, H., & Ali, H. (2015). Human factors considerations in the design of falls prevention technologies for nursing homes: A case study. Proceedings of 2015 Symposium on Human Factors and Ergonomics in Health Care.
- Lu, T.-C., Fu, C.-M., Ma, M.-H.-M., Fang, C.-C., & Turner, A. M. (2016). Healthcare applications of smart watches: A systematic review. Applied Clinical Informatics, 7(3), 850–869. https://doi.org/10.4338/ACI-2016-03-RA-0042
- Maglogiannis, I., Spyroglou, G., Panagopoulos, C., & Mazonaki, M. (2014). Mobile reminder system for furthering patient adherence utilizing commodity smartwatch and Android devices. In 2014 EAI 4th International Conference on Wireless Mobile Communication and Healthcare (Mobihealth), pp. 124–127; 2014 Nov 3–5; Athens, Greece: IEEE Xplore, 2014.
- McCabe, C. (2003). Nurse–patient communication: An exploration of patients' experiences. Journal of Clinical Nursing, 13(1), 1–28.
- Meade, C. M., Bursell, A. L., & Ketelsen, L. (2006). Effects of nursing rounds on patients' call light use, satisfaction, and safety. American Journal of Nursing, 106(9), 58–70.
- Mortazavi, B., Nemati, E., VanderWall, K., Flores-Rodriguez, H. G., Cai, J. Y., Lucier, J., … Sarrafzadeh, M. (2015). Can smartwatches replace smartphones for posture tracking? Sensors (Basel), 15(10), 26783–26800. https://doi.org/10.3390/s151026783
- Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012). A review of wearable sensors and systems with application in rehabilitation. Journal of NeuroEngineering and Rehabilitation, 9, 21. https://doi.org/10.1186/1743-0003-9-21
- Pemmasani, V., Paget, T., van Woerden, H. C., Minamareddy, P., & Pemmasani, S. (2014). Hands-free communication to free up nursing time. Nursing times, 110(13), 12–14.
- Sailer, F., Pobiruchin, M., & Wiesner, M. (2015). An approach to improve medication adherence by smart watches. In The 26th Medical Informatics Europe Conference: Digital Healthcare Empowering Europeans: Proceedings of MIE2015; 2015. May 27–29; Madrid, Spain.
- Saliba, D., Kington, R., Buchanan, J., Bell, R., Wang, M., Lee, M., … Rubenstein, L. (2000). Appropriateness of the decision to transfer nursing facility residents to the hospital. Journal of the American Geriatrics Society, 48, 154–163.
- Scher, D. L. (2015). Will the Apple Watch Revolutionize Healthcare? Retrieved from http://www.medscape.com/viewarticle/845762
- Sirkka, A., Fagerlönn, J., Lindberg, S., & Delsing, K. (2014). The design of an auditory alarm concept for a paper mill control room. In R. Francisco & S, Marcelo (Eds.), Advances in ergonomics in design, usability, & special populations: Part III. (Proceedings of the 5th AHFE Conference)
- Stegemann, S. (2015). The future of pharmaceutical manufacturing in the context of the scientific, social, technological and economic evolution. European Journal of Pharmaceutical Sciences, 90(30), 8–13.
- Stokowski, L. A. (2008). Ring for the nurse!. Medscape website: Improving call light management. Retrieved from http://www.medscape.org/viewarticle/570242
- Tak, S. H., Benefield, L., & Mahoney, D. F. (2010). Technology for long-term care. Research in Gerontological Nursing, 3(1), 61–72. https://doi.org/10.3928/19404921-20091103-01
- Tang, C., & Carpendale, S. (2008). A Mobile Voice Communication System in Medical Setting: Love it or Hate it?. CIN. Computers, Informatics, Nursing, 26(3), 159–166.
- Tzeng, H. (2011a). Perspectives of patients and families about the nature of and reasons for call light use and staff call light response time. MEDSURG Nursing: The Journal of Adult Health, 20, 225–234.
- Tzeng, H. (2011b). Perspectives of staff nurses toward patient- and family-initiated call light usage and response time to call lights. Applied Nursing Research, 24(1), 59–63.
- Tzeng, H., & Yin, C. (2008). The extrinsic risk factors for inpatient falls in hospital patient rooms. Journal of Nursing Care Quality, 25(3), 233–241.
- Tzeng, H., & Yin, C. (2009). Are call light use and response time correlated with inpatient falls and inpatient dissatisfaction? Journal of Nursing Care Quality, 24(3), 232–242.
- Tzeng, H., & Yin, C. (2010). Predicting patient satisfaction with nurses' call light responsiveness in 4 US hospitals. Journal of Nursing Administration, 40(10), 440–447.
- Varga, N., Bokor, L., & Takács, A. (2014). Context-aware IPv6 flow mobility for multi-sensor based mobile patient monitoring and tele-consultation. Procedia Computer Science, 40, 222–229.
10.1016/j.procs.2014.12.030 Google Scholar
- Veer, A., Fleuren, M., Bekkema, N., & Francke, A. (2011). Successful implementation of new technologies in nursing care: A questionnaire survey of nurse users. BMC Medical Informatics and Decision Making, 11, 67. https://doi.org/10.1186/1472-6947-11-67
- Wickens, C. D. (2008). Multiple resources and mental workload. Human Factors, 50(3), 449–455.
- Wu, R. C., Tran, K., Lo, V., O'Leary, K. J., Morra, D., Quan, S. D., & Perrier, L. (2012). Effects of clinical communication interventions in hospitals: A systematic review of information and communication technology adoptions for improved communication between clinicians. International Journal of Medical Informatics, 81(11), 723–732.
- Yang, Y., & Rivera, A. (2015). An observational study of hands-free communication devices mediated interruption dynamics in a nursing work system. Health Policy and Technology, 4(4), 378–386.