Volume 32, Issue 2 e13178
ORIGINAL ARTICLE

Revealing a new mode of sensitization induced by mechanical circulatory support devices: Impact of anti-AT1R antibodies

Xiaohai Zhang

Corresponding Author

Xiaohai Zhang

HLA and Immunogenetics Laboratory, Comprehensive Transplant Center, Cedars-Sinai Health System, Los Angeles, CA, USA

Correspondence

Xiaohai Zhang, PhD, HLA and Immunogenetics Laboratory, Comprehensive Transplant Center, Cedars-Sinai Health Systems, Los Angeles, CA, USA.

Email: [email protected]

Search for more papers by this author
James Mirocha

James Mirocha

Biostatistics Core, Cedars-Sinai Health System, Los Angeles, CA, USA

Search for more papers by this author
Tamar Aintablian

Tamar Aintablian

California Heart Center, Los Angeles, CA, USA

Search for more papers by this author
Sadia Dimbil

Sadia Dimbil

California Heart Center, Los Angeles, CA, USA

Search for more papers by this author
Jaime Moriguchi

Jaime Moriguchi

Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA, USA

Search for more papers by this author
Francisco Arabia

Francisco Arabia

Cardiovascular Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, USA

Search for more papers by this author
Jon A. Kobashigawa

Jon A. Kobashigawa

Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA, USA

Search for more papers by this author
Nancy Reinsmoen

Nancy Reinsmoen

HLA and Immunogenetics Laboratory, Comprehensive Transplant Center, Cedars-Sinai Health System, Los Angeles, CA, USA

Search for more papers by this author
First published: 15 December 2017
Citations: 18

Abstract

Background

Increased levels of angiotensin II type 1 receptor (AT1R) antibody have been shown to be associated with allograft rejection. This study aims to determine the rate of development of antibody to AT1R after mechanical circulatory support device (MCS) implantation, and if the development of strong binding AT1R antibodies is associated with survival.

Methods

Eighty-eight patients who had one MCS implantation were accessed based on serum availability. Mechanical circulatory support devices in this cohort included pneumatic bilateral paracorporeal ventricular assist device, continuous flow left ventricular assist device, and total artificial heart.

Results

Of 88 patients, seven patients had AT1R antibodies ≥40 U/mL preimplantation. For 81 patients who had AT1R antibodies <40 U/mL, the median value was 8 U/mL. Of these 81 patients, AT1R antibody levels in 55 (68%) patients reached the saturated concentration (≥40 U/mL) postimplantation (< .0001), with the highest percentage of patients with the saturated level of AT1R antibody observed in the pneumatic bilateral paracorporeal ventricular assist device group. Compared to patients without the saturated level of AT1R antibodies, patients with the saturated AT1R antibody level had lower 18-month survival (= .040).

Conclusion

Mechanical circulatory support devices implantation significantly increases AT1R antibody levels. The saturated level of AT1R antibodies is associated with lower patient survival postimplantation.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.