Volume 23, Issue 4 pp. 315-321

Kinetic profile of carbamazepine in an adult Portuguese outpatient population

A. M. Almeida MScA. C. Falcão PhDF. Sales MD

F. Sales MD

Neurology Department, Coimbra University Hospital, 3000 Coimbra, Portugal

Search for more papers by this author
F. Leitão MD

F. Leitão MD

Laboratory of Hormonology and Therapeutic Drug Monitoring, Coimbra University Hospital, 3000 Coimbra, Portugal

Search for more papers by this author
J. Santos PharmD

J. Santos PharmD

Laboratory of Hormonology and Therapeutic Drug Monitoring, Coimbra University Hospital, 3000 Coimbra, Portugal

Search for more papers by this author
I. M. Costa PharmDM. M. Caramona PhD
First published: 09 October 2008
Citations: 4
A. C.Falcão Tel: + 351 398 20510; fax + 351 39 37731; e-mail [email protected]

Abstract

Objective : The aim of our work was to define the kinetic profile of carbamazepine (CBZ), in order to improve on dosing schedules through a Bayesian approach. Method: Carbamazepine dose/steady-state trough concentrations data pairs and associated information were collected retrospectively on a population of adult epileptic patients. Results: Fifty patients (index population) with two or more available concentrations (total of 174 determinations) met our inclusion criteria. Patients were taking CBZ (200–1800 mg/day) in mono- or polytherapy regimens. The analysis assumed a one-compartimental model with first-order absorption and elimination. Due to the data source (only trough concentrations were measured as part of hospital routine), the volume of distribution was fixed at 1·19 l/kg. The final estimates for CL were: 0·075± 0·027 (mono- and polytherapy), 0·069±0·020 (monotherapy), and 0·106±0·037 l/h/kg (poly?therapy). In order to validate these results, we assessed their predictive capacity using 18 new patients (validation population), submitted to the same inclusion criteria and using Prediction-Error analysis. The results suggested a different CL value for our population compared to earlier published clearance values. The results also pointed to an increased metabolic rate associated with polytherapy. The prediction capacity of the optimization method derived from a Portuguese population made in an a priori evaluation indicated a low error (–0·04 μg/ml), close to the theoretical zero value. Conclusion: Our results provide specific data on CBZ disposition in a Portuguese population and given the wide variability in the literature values, our data may help improve dosing of CBZ in Portuguese patients.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.