Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition
Corresponding Author
Huimin Wu
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Medical Physics, Wisconsin Institutes Medical Research, 1111 Highland Avenue, Room 1005, Madison, WI 53705-2275===Search for more papers by this authorWalter F. Block
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorPatrick A. Turski
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorCharles A. Mistretta
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorKevin M. Johnson
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorCorresponding Author
Huimin Wu
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Medical Physics, Wisconsin Institutes Medical Research, 1111 Highland Avenue, Room 1005, Madison, WI 53705-2275===Search for more papers by this authorWalter F. Block
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorPatrick A. Turski
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorCharles A. Mistretta
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorKevin M. Johnson
Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
Search for more papers by this authorAbstract
Pseudocontinuous arterial spin labeling (PCASL) can be used to generate noncontrast magnetic resonance angiograms of the cerebrovascular structures. Previously described PCASL-based angiography techniques were limited to two-dimensional projection images or relatively low-resolution three-dimensional (3D) imaging due to long acquisition time. This work proposes a new PCASL-based 3D magnetic resonance angiography method that uses an accelerated 3D radial acquisition technique (VIPR, spoiled gradient echo) as the readout. Benefiting from the sparsity provided by PCASL and noise-like artifacts of VIPR, this new method is able to obtain submillimeter 3D isotropic resolution and whole head coverage with a 8-min scan. Intracranial angiography feasibility studies in healthy (N = 5) and diseased (N = 5) subjects show reduced saturation artifacts in PCASL-VIPR compared with a standard time-of-flight protocol. These initial results show great promise for PCASL-VIPR for static, dynamic, and vessel selective 3D intracranial angiography. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
REFERENCES
- 1 Xu J, Kochanek K, Murphy S, Tejada-Vera B. Deaths: final data for 2007. Natl Vital Stat Rep 2007; 58(19).
- 2 Grohn O, Kauppinen R. Assessment of brain tissue viability in acute ischemic stroke by BOLD MRI. NMR Biomed 2001; 14: 432–440.
- 3 Grandin CB. Assessment of brain perfusion with MRI: methodology and application to acute stroke. Neuroradiology 2003; 45: 755–766.
- 4 Atlas SW, Thulborn KR. Intracranial hemorrhage. In: Atlas SW, ed. Magnetic resonance imaging of the brain and spine, 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2002. pp 773–832.
- 5 Parker DL, Yuan C, Blatter DD. MR angiography by multiple thin slab 3D acquisition. Magn Reson Med 1991; 17: 434–451.
- 6Axel L. Blood flow effects in magnetic resonance imaging. AJR Am J Roentgenol. 1984; 143(6): 1157–1166
- 7 Haider C, Borisch E, Glockner J, Mostardi P, Rossman P, Young P, Riederer S. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds. Magn Reson Med 2010; 64: 1171–1181.
- 8 Velikina JV, Johnson KM, Wu Y, Samsonov AA, Turski P, Mistretta CA. PC HYPR flow: a technique for rapid imaging of contrast dynamics. J Magn Reson Imaging 2010; 31: 447–456.
- 9 Wu Y, Kim N, Korosec FR, Turk A, Rowley HA, Wieben O, Mistretta CA, Turski PA. 3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction. AJNR Am J Neuroradiol 2007; 28: 2001–2004.
- 10 Miyazaki M, Lee VS. Nonenhanced MR angiography. Radiology 2008; 248: 20–43.
- 11 Miyazaki M, Akahane M. Non-contrast enhanced MR angiography: established techniques. J Magn Reson Imaging 2012; 35: 1–19.
- 12 Nishimura DG, Macovski A, Pauly JM, Conolly SM. MR angiography by selective inversion recovery. Magn Reson Med 1987; 4: 193–202.
- 13 Tan ET, Huston J 3rd, Campeau NG, Riederer SJ. Fast inversion recovery magnetic resonance angiography of the intracranial arteries. Magn Reson Med 2010; 63: 1648–1658.
- 14 Johnson KM, Wieben O, Block WF, Mistretta CA. Accelerated time resolved inflow imaging with 3D radial bSSFP. In: ISMRM Workshop on Data Sampling and Image Reconstruction, Sedona, AZ, USA, 2009.
- 15 Chen Q, Mai VM, Storey P, Edelman RR. Dynamic ASL flow imaging with cardiac triggered true FISP acquisition. In: Proc Int Soc Magn Reson Med. Volume 9; 2001. p 1956.
- 16 Yan L, Wang S, Zhuo Y, Wolf RL, Stiefel MF, An J, Ye Y, Zhang Q, Melhem E, Wang DJJ. Unenhanced dynamic MR angiography: high spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency. Radiology 2010; 256: 270–279.
- 17 Bi X, Weale P, Schmitt P, Zuehlsdorff S, Jerecic R. Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study. Magn Reson Med 2010; 63: 835–841.
- 18 Dai W, Garcia D, de Bazelaire C, Alsop D. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 2008; 60: 1488–1497.
- 19 Wong E. Vessel-encoded arterial spin-labeling using pseudocontinuous tagging. Magn Reson Med 2007; 58: 1086–1091.
- 20 Koktzoglou I, Gupta N, Edelman R. Nonenhanced extracranial carotid MR angiography using arterial spin labeling: improved performance with pseudocontinuous tagging. J Magn Reson Imaging 2011; 34: 384–394.
- 21 Robson P, Dai W, Shankaranarayanan A, Rofsky N, Alsop D. Time-resolved vessel-selective digital subtraction MR angiography of the cerebral vasculature with arterial spin labeling. Radiology 2010; 257: 507–515.
- 22 Okell TW, Chappell MA, Woolrich MW, Gunther M, Feinberg DA, Jezzard P. Vessel-encoded dynamic magnetic resonance angiography using arterial spin labeling. Magn Reson Med 2010; 64: 698–706.
- 23 Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002; 48: 297–305.
- 24 Hargreaves BA, Cunningham CH, Nishimura DG, Conolly SM. Variable-rate selective excitation for rapid MRI sequences. Magn Reson Med 2004; 52: 590–597.
- 25 Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995; 34: 293–301.
- 26 Bieri O, Scheffler K. Flow compensation in balanced SSFP sequences. Magn Reson Med 2005; 54: 901–907.
- 27
Peters DC,
Korosec FR,
Grist TM,
Block WF,
Holden JE,
Vigen KK,
Mistretta CA.
Undersampled projection reconstruction applied to MR angiography.
Magn Reson Med
2000;
43:
91–101.
10.1002/(SICI)1522-2594(200001)43:1<91::AID-MRM11>3.0.CO;2-4 CAS PubMed Web of Science® Google Scholar
- 28 Holmes BH, O'Halloran RL, Brodsky EK, Jung Y, Block WF, Fain SB. 3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition. Magn Reson Med 2008; 59: 1062–1071.
- 29 Altbach MI, Outwater EK, Trouard TP, Krupinski EA, Theilmann RJ, Stopeck AT, Kono M, Gmitro AF. Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver. J Magn Reson Imaging 2002; 16: 179–189.
- 30 Theilmann RJ, Gmitro AF, Altbach MI, Trouard TP. View-ordering in radial fast spin-echo imaging. Magn Reson Med 2004; 51: 768–774.
- 31 Beatty PJ, Nishimura DG, Pauly JM. Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging 2005; 24: 799–808.
- 32 McKenzie CA, Yeh EN, Ohliger MA, Price MD, Sodickson DK. Self-calibrating parallel imaging with automatic coil sensitivity extraction. Magn Reson Med 2002; 47: 529–538.
- 33 Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 2000; 44: 602–609.
- 34 Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med 1990; 16: 192–225.
- 35 Buis DR, Bot JC, Barkhof F, Knol DL, Lagerwaard FJ, Slotman BJ, Vandertop WP, van den Berg R. The predictive value of 3D time-of-flight MR angiography in assessment of brain arteriovenous malformation obliteration after radiosurgery. AJNR Am J Neuroradiol 2012; 33: 232–238.
- 36 Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182–1195.
- 37 Jung Y, Wong EC, Liu T. Multiphase pseudocontinuous arterial spin labeling (MP-PCASL) for robust quantification of cerebral blood flow. Magn Reson Med 2010; 64: 799–810.
- 38 Jahanian H, Noll D, Hernandez-Garcia L. B(0) field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy. NMR Biomed 2011; 24: 1202–1209.