Volume 7, Issue 1 pp. 238-239
CLINICAL IMAGE
Open Access

An alternative technique for downsizing a modified Blalock-Taussig shunt

Dimitrios Bobos

Dimitrios Bobos

Department of Paediatric and Congenital Heart Surgery, Onassis Cardiac Surgery Centre, Athens, Greece

Search for more papers by this author
Meletios Kanakis

Meletios Kanakis

Department of Paediatric and Congenital Heart Surgery, Onassis Cardiac Surgery Centre, Athens, Greece

Search for more papers by this author
Evangelia Grisbolaki

Corresponding Author

Evangelia Grisbolaki

Department of Paediatric and Congenital Heart Surgery, Onassis Cardiac Surgery Centre, Athens, Greece

Correspondence

Evangelia Grisbolaki, Department of Paediatric and Congenital Cardiac Surgery, Onassis Cardiac Surgery Centre, Athens, Greece.

Email: [email protected]

Search for more papers by this author
Nicholas Giannopoulos

Nicholas Giannopoulos

Department of Paediatric and Congenital Heart Surgery, Onassis Cardiac Surgery Centre, Athens, Greece

Search for more papers by this author
First published: 28 November 2018

Key Clinical Message

An alternative surgical approach for downsizing an existed modified Blalock-Taussig shunt is described as a reoperation in a hemodynamically unstable patient. This method was selected in order to minimize the surgical manipulations in the setting of a critically ill infant.

1 TECHNIQUE

Modified Blalock-Taussig (B-T) shunt has critical impact on the potential outcome of future surgeries on the same patient.1 A 10-month-old boy, 8.4 kg, with d-transposition of the great arteries (TGA), VSD, and subpulmonary obstruction, underwent a modified B-T shunt with a 5-mm conduit. Postoperatively, the patient developed pulmonary overcirculation due to oversized B-T shunt (Figure 1A). Critical status of our patient entailed minimal surgical manipulation, so a smaller conduit was tightly wrapped around the previous B-T shunt off pump.

Details are in the caption following the image
Chest X-ray showing the pulmonary edema (A) and the improvement on the postoperative day 6 (B)

A 5-mm Gore-Tex was used again. The graft was longitudinally incised creating an oblong shape; the width corresponded to the perimeter of the graft (15.7 mm; Figure 2A).

Details are in the caption following the image
A, Schematic representation depicting a longitudinally opened 5 mm graft in an oblong shape; the width of this corresponds to the perimeter of the graft. B, Schematic representation showing the marked width, which corresponds to the desirable perimeter of a 4 mm graft. C, Schematic representation of the created downsized graft by multiple 6-0 prolene in an axial level, which shows the created eversion of the pre-existed graft (perimeter = 2πR = πδ)

Perimeter had to be the same as of the 4 mm graft, so we have marked the width of this oblong to the desirable perimeter (12.56 mm; Figure 2B).

Dissection of the existed shunt from edge to edge was performed (Figure 3A) and then girdling with the new one by suturing it in the marked diameter. Interrupted “U-shaped” 6-0 prolene sutures (Figure 3B) were placed creating eversion of the existed graft to prevent thrombosis (Figure 2C).

Details are in the caption following the image
Intraoperative photograph showing the existed B-T shunt (A) and the created downsized girdling graft (B)

The patient had an uneventful recovery, and the shunt was functional 6 months later (Figure 1B).

CONFLICT OF INTEREST

None declared.

AUTHOR CONTRIBUTION

DB: had the main idea for this alternative surgical approach and helped to draft the manuscript. MK: participated in the main idea for this surgical approach and in the design of the manuscript and drafted the manuscript. EG: participated in the design of the manuscript. NG: conceived of the manuscript idea and participated in its design. All authors read and approved the final manuscript.

    The full text of this article hosted at iucr.org is unavailable due to technical difficulties.