Volume 29, Issue 6 e12019
RESEARCH ARTICLE

An experimental investigation of new electromagnetic field signal for stator asymmetric fault detection of doubly fed induction generators

Hoang-Giang Vu

Corresponding Author

Hoang-Giang Vu

Faculty of Electrical Engineering, Electric Power University, Hanoi, Vietnam

Correspondence

Hoang-Giang Vu, Faculty of Electrical Engineering, Electric Power University, Hanoi, Vietnam.

Email: [email protected]

Search for more papers by this author
Hamed Yahoui

Hamed Yahoui

CNRS, UMR 5005, Ampere, Université de Lyon, Lyon, France

Search for more papers by this author
Hassan Hammouri

Hassan Hammouri

CNRS, UMR 5007, LAGEPP, Université Lyon 1, Villeurbanne, France

Search for more papers by this author
First published: 09 April 2019
Citations: 6

Summary

The paper presents an investigation of a new electromagnetic signal for the diagnosis of the doubly fed induction generator (DFIG). The signal is acquired by using a dedicated sensor located on the bus surface of the DC link in the DFIG system. To demonstrate the feasibility and efficiency of applying this signal in condition monitoring of DFIG, a procedure of diagnosing stator asymmetrical fault is shown. Physical phenomena of the defect are first analysed to obtain the harmonic signature. Afterwards, the benchmark will be processed with the defect to extract the specific signature in the DC bus magnetic field. The experiment results show that the proposed signal can be efficiently applied in the diagnosis of wind power generators.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.