Abstract
The sections in this article are
- 1 Instrumentation
- 2 Microbalances and Vacuum Microbalances
Balance Types
- W. Sprikl E. Lavemann H. Ries An easy-to-build balance for automatic measurement, J. Phys. E: Sci. Instrum., 20: 1452–1454, 1987.
- G. L. Miller et al. A rocking beam electrostatic balance for the measurement of small forces, Rev. Sci. Instrum., 62: 705–709, 1992.
- R. M. Schoonover Mass Comparator for In-situ Calibration of Large Mass Standards, J. Res. Nat. Bur. Stands., 90: 289–294, 1985.
- J. T. Buontempo F. A. Novak An inexpensive Wilhelmy balance for the study of Langmuir monolayers, Rev. Sci. Instrum., 63: 5707–5713, 1992.
- G. T. Gillies R. C. Ritter Torsion balances and torsion pendulums, Rev. Sci. Instrum., 64: 283–309, 1993.
- S. Gordon C. Campbell Automatic and Recording Balances, Anal. Chem., 32: 271R–289R, 1960.
Non-Quartz Crystal Microbalances
- L. Bruschi et al. Novel needle microbalance for adsorption studies, Rev. Sci. Instrum., 68: 4536–4541, 1997.
- S. J. Suh H. J. Eun Small-mass measurement by optical glass-fibre elastic cantilever, Meas. Sci. Technol., 1: 556–560, 1990.
- L. Bruschi G. Torzo A vibrating fibre microbalance for measuring layer-by-layer adsorption on graphite, Rev. Sci. Instrum., 62: 2772–2777, 1991.
- N. Uetake T. Asano K. Suzuki Measurement of vaporized atom flux and velocity in a vacuum using a microbalance, Rev. Sci. Instrum., 62: 1942–1946, 1991.
- D. M. Astill P. L. Hall J. D. C. McConnell An automated vacuum microbalance for measurement of adsorption isotherms, J. Phys. E: Sci. Instrum., 20: 19–21, 1987.
- J. E. Sader et al. Method for the calibration of atomic force microscope cantilevers, Rev. Sci. Instrum., 66: 3789–3798, 1995.
- A. Torii et al. A method for determining the spring constant of cantilevers for atomic force microscopy, Meas. Sci. Technol., 7: 179–184, 1996.
- L. I. Maissel R. Glang (eds.) Handbook of Thin Film Technology, New York: McGraw-Hill, 1970, pp. 1–103 ff.
Quartz Crystal Microbalances
- D. S. Ballantine H. Wohltjen Surface acoustic wave devices for chemical analysis, Anal. Chem., 61: 704A–712A, 1989.
- M. R. Deakin D. A. Buttry Electrochemical applications of QCM, Anal. Chem., 61: 1147A–1154A, 1989.
- A. Wajid Improving the accuracy of a quartz crystal microbalance with automatic determination of acoustic impedance ratio, Rev. Sci. Instrum., 62: 2026–2033, 1991.
- E. Benes Improved quartz crystal microbalance technique, J. Appl. Phys., 56: 608–626, 1984.
- P. J. Cumpson M. P. Seah The quartz crystal microbalance; radial/polar dependence of mass sensitivity both on and off the electrodes, Meas. Sci. Techonl., 1: 544–555, 1990.
- M. D. Ward E. J. Delawski Radial mass sensitivity of the QCM in liquid media, Anal. Chem., 63: 886–890, 1991.
- Product Review: Quartz crystal microbalances, Anal. Chem., 68: 625A–628A, 1996.
- M. Rodahl B. Kasemo A simple setup to simultaneously measure the resonant frequency and absolute dissipation factor of a quartz crystal microbalance, Rev. Sci. Instrum., 67: 3238–3930, 1996.
- S. Bruckenstein et al. Dual quartz crystal oscillator circuit. Minimizing effects due to liquid viscosity, density, and temperature, Anal. Chem., 66: 1847–1852, 1994.
- W. D. Bowers R. L. Chuan T. M. Duong A 200 MHz surface acoustic wave resonator mass microbalance, Rev. Sci. Instrum., 62: 1624–1629, 1991.
- W. D. Bowers R. L. Chuan Surface acoustic-wave piezoelectric crystal aerosol mass microbalance, Rev. Sci. Instrum., 60: 1297–1302, 1989.
Wiley Encyclopedia of Electrical and Electronics Engineering