Termination of Persistent Atrial Fibrillation During Ablation: Finding the Needle in the Haystack
Corresponding Author
MICHAEL P. RILEY M.D., Ph.D.
Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Address for correspondence: Michael P. Riley, M.D., Ph.D., Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, 9 Founders Pavilion, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA. Fax: 215-615-5235; E-mail: [email protected]Search for more papers by this authorFRANCIS E. MARCHLINSKI M.D.
Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Search for more papers by this authorCorresponding Author
MICHAEL P. RILEY M.D., Ph.D.
Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Address for correspondence: Michael P. Riley, M.D., Ph.D., Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, 9 Founders Pavilion, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA. Fax: 215-615-5235; E-mail: [email protected]Search for more papers by this authorFRANCIS E. MARCHLINSKI M.D.
Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Search for more papers by this authorNo disclosures.

References
- 1Van Gelder IC, Crijns HJ, Tieleman RG, Brugemann J, De Kam PJ, Gosselink AT, Verheugt FW, Lie KI: Chronic atrial fibrillation. Success of serial cardioversion therapy and safety of oral anticoagulation. Arch Intern Med 1996; 156: 2585-2592.
- 2Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, Garrigue S, Le Mouroux A, Le Metayer P, Clementy J: Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659-666.
- 3Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, Crijns HJ, Damiano RJJr, Davies DW, DiMarco J, Edgerton J, Ellenbogen K, Ezekowitz MD, Haines DE, Haissaguerre M, Hindricks G, Iesaka Y, Jackman W, Jalife J, Jais P, Kalman J, Keane D, Kim YH, Kirchhof P, Klein G, Kottkamp H, Kumagai K, Lindsay BD, Mansour M, Marchlinski FE, McCarthy PM, Mont JL, Morady F, Nademanee K, Nakagawa H, Natale A, Nattel S, Packer DL, Pappone C, Prystowsky E, Raviele A, Reddy V, Ruskin JN, Shemin RJ, Tsao HM, Wilber D; Heart Rhythm Society Task Force on Catheter and Surgical Ablation of Atrial Fibrillation: 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm 2012; 9: 632-696.e21.
- 4Hutchinson MD, Garcia FC, Mandel JE, Elkassabany N, Zado ES, Riley MP, Cooper JM, Bala R, Frankel DS, Lin D, Supple GE, Dixit S, Gerstenfeld EP, Callans DJ, Marchlinski FE: Efforts to enhance catheter stability improve atrial fibrillation ablation outcome. Heart Rhythm 2013; 10: 347-353.
- 5Callans DJ, Gerstenfeld EP, Dixit S, Zado E, Vanderhoff M, Ren JF, Marchlinski FE: Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation. J Cardiovasc Electrophysiol 2004; 15: 1050-1055.
- 6Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, Esposito C, Furlanello F, De Ambroggi L: Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation 2003; 108: 1599-1604.
- 7Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bansch D, Kuck KH: Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double Lasso technique. Circulation 2005; 111: 127-135.
- 8Dixit S, Gerstenfeld EP, Ratcliffe SJ, Cooper JM, Russo AM, Kimmel SE, Callans DJ, Lin D, Verdino RJ, Patel VV, Zado E, Marchlinski FE: Single procedure efficacy of isolating all versus arrhythmogenic pulmonary veins on long-term control of atrial fibrillation: A prospective randomized study. Heart Rhythm 2008; 5: 174-181.
- 9Dixit S, Marchlinski FE, Lin D, Callans DJ, Bala R, Riley MP, Garcia FC, Hutchinson MD, Ratcliffe SJ, Cooper JM, Verdino RJ, Patel VV, Zado ES, Cash NR, Killian T, Tomson TT, Gerstenfeld EP: Randomized ablation strategies for the treatment of persistent atrial fibrillation: RASTA study. Circ Arrhythm electrophysiol 2012; 5: 287-294.
- 10Lin D, Frankel DS, Zado ES, Gerstenfeld E, Dixit S, Callans DJ, Riley M, Hutchinson M, Garcia F, Bala R, Verdino R, Cooper J, Marchlinski FE: Pulmonary vein antral isolation and nonpulmonary vein trigger ablation without additional substrate modification for treating longstanding persistent atrial fibrillation. J Cardiovasc Electrophysiol 2012; 23: 806-813.
- 11Tzou WS, Marchlinski FE, Zado ES, Lin D, Dixit S, Callans DJ, Cooper JM, Bala R, Garcia F, Hutchinson MD, Riley MP, Verdino R, Gerstenfeld EP: Long-term outcome after successful catheter ablation of atrial fibrillation. Circ Arrhythm electrophysiol 2010; 3: 237-242.
- 12Brooks AG, Stiles MK, Laborderie J, Lau DH, Kuklik P, Shipp NJ, Hsu LF, Sanders P: Outcomes of long-standing persistent atrial fibrillation ablation: A systematic review. Heart Rhythm 2010; 7: 835-846.
- 13Cox JL: The surgical treatment of atrial fibrillation. IV. Surgical technique. J Thorac Cardiovasc Surg 1991; 101: 584-592.
- 14Nademanee K, McKenzie J, Kosar E, Schwab M, Sunsaneewitayakul B, Vasavakul T, Khunnawat C, Ngarmukos T: A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate. J Am Coll Cardiol 2004; 43: 2044-2053.
- 15Nademanee K, Schwab MC, Kosar EM, Karwecki M, Moran MD, Visessook N, Michael AD, Ngarmukos T: Clinical outcomes of catheter substrate ablation for high-risk patients with atrial fibrillation. J Am Coll Cardiol 2008; 51: 843-849.
- 16Narayan SM, Krummen DE, Rappel WJ: Clinical mapping approach to diagnose electrical rotors and focal impulse sources for human atrial fibrillation. J Cardiovasc Electrophysiol 2012; 23: 447-454.
- 17Di Biase L, Elayi CS, Fahmy TS, Martin DO, Ching CK, Barrett C, Bai R, Patel D, Khaykin Y, Hongo R, Hao S, Beheiry S, Pelargonio G, Dello Russo A, Casella M, Santarelli P, Potenza D, Fanelli R, Massaro R, Wang P, Al-Ahmad A, Arruda M, Themistoclakis S, Bonso A, Rossillo A, Raviele A, Schweikert RA, Burkhardt DJ, Natale A: Atrial fibrillation ablation strategies for paroxysmal patients: Randomized comparison between different techniques. Circ Arrhythm electrophysiol 2009; 2: 113-119.
- 18Oral H, Chugh A, Good E, Wimmer A, Dey S, Gadeela N, Sankaran S, Crawford T, Sarrazin JF, Kuhne M, Chalfoun N, Wells D, Frederick M, Fortino J, Benloucif-Moore S, Jongnarangsin K, Pelosi FJr, Bogun F, Morady F: Radiofrequency catheter ablation of chronic atrial fibrillation guided by complex electrograms. Circulation 2007; 115: 2606-2612.
- 19Verma A, Mantovan R, Macle L, De Martino G, Chen J, Morillo CA, Novak P, Calzolari V, Guerra PG, Nair G, Torrecilla EG, Khaykin Y: Substrate and trigger ablation for reduction of atrial fibrillation (STAR AF): A randomized, multicentre, international trial. Eur Heart J 2010; 31: 1344-1356.
- 20Narayan SM, Krummen DE, Shivkumar K, Clopton P, Rappel WJ, Miller JM: Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial. J Am Coll Cardiol 2012; 60: 628-636.
- 21Shivkumar K, Ellenbogen KA, Hummel JD, Miller JM, Steinberg JS: Acute termination of human atrial fibrillation by identification and catheter ablation of localized rotors and sources: First multicenter experience of focal impulse and rotor modulation (FIRM) ablation. J Cardiovasc Electrophysiol 2012; 23: 1277-1285.
- 22Zhou G, Chen S, Chen G, Zhang F, Meng W, Yan Y, Lu X, Wei Y, Liu S: Procedural arrhythmia termination and long-term single-procedure clinical outcome in patients with non-paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2013; 24:DOI:10.1111/jce.12193
10.1111/jce.12193 Google Scholar
- 23Roten L, Derval N, Jais P: Catheter ablation for persistent atrial fibrillation: Elimination of triggers is not sufficient. Circ Arrhythm electrophysiol 2012; 5: 1224-1232.