Volume 48, Issue 4 pp. 525-531
Research Article

Dynamic sonographic measurements at the carpal tunnel inlet: Reliability and reference values in healthy wrists

Anika Filius MD

Corresponding Author

Anika Filius MD

Department of Plastic and Reconstructive Surgery and Hand Surgery, Erasmus MC, University Medical Centre Rotterdam, P.O. Box 2040, 3000CA, Rotterdam, The Netherlands

Correspondence to: A. Filius; e-mail: [email protected]Search for more papers by this author
Jan-Wiebe H. Korstanje PhD

Jan-Wiebe H. Korstanje PhD

Department of Rehabilitation Medicine and Physical Therapy, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands

Search for more papers by this author
Ruud W. Selles PhD

Ruud W. Selles PhD

Department of Rehabilitation Medicine and Physical Therapy, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands

Search for more papers by this author
Steven E.R. Hovius MD, PhD

Steven E.R. Hovius MD, PhD

Department of Plastic and Reconstructive Surgery and Hand Surgery, Erasmus MC, University Medical Centre Rotterdam, P.O. Box 2040, 3000CA, Rotterdam, The Netherlands

Search for more papers by this author
Harm P. Slijper PhD

Harm P. Slijper PhD

Department of Rehabilitation Medicine and Physical Therapy, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands

Search for more papers by this author
First published: 30 January 2013
Citations: 16

ABSTRACT

Introduction: Reliability and reference values are not well-established for most dynamic sonographic measurements of the median nerve (MN) and flexor tendons that may be used for diagnosing carpal tunnel syndrome (CTS). Methods: Wrists of 20 healthy participants were imaged using ultrasound. Cines of the carpal tunnel inlet were acquired during hand motion. Based on shape and displacement measurements, intra- and interrater reliability and reference values were calculated. Results: Intraclass correlation coefficients (ICCs) for measurements of the MN and most flexor tendons were ≥0.51 for shape parameters and ≥0.71 for displacement parameters. During motion, the MN flattened with ulnar movement, tendons became more circular, and flexor tendons of corresponding fingers moved toward each other. Conclusion: Shape and displacement measurements of the MN and most flexor tendons had reliability results ranging from moderate to excellent. The reference values may be useful for the diagnosis of CTS. Muscle Nerve 48: 525–531, 2013

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.

click me