Volume 70, Issue 6 pp. 1557-1566
Full Paper

A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized 3He MRI

Hooman Hamedani

Corresponding Author

Hooman Hamedani

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Correspondence to: Hooman Hamedani, B.Sc., Department of Radiology, University of Pennsylvania, 338 Stemmler Hall, 3450 Hamilton Walk, Philadelphia, PA. E-mail: [email protected]Search for more papers by this author
Stephen J. Kadlecek

Stephen J. Kadlecek

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
Masaru Ishii

Masaru Ishii

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins University, Baltimore, Maryland, USA

Search for more papers by this author
Kiarash Emami

Kiarash Emami

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
Nicholas N. Kuzma

Nicholas N. Kuzma

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
Yi Xin

Yi Xin

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
Milton Rossman

Milton Rossman

Division of Pulmonary, Allergy and Critical Care, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
Rahim R. Rizi

Rahim R. Rizi

Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA

Search for more papers by this author
First published: 04 February 2013
Citations: 15

Abstract

Purpose

A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pAO2) measurements using 3He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pAO2 was compared with that of the standard pulmonary function tests.

Methods

Pulmonary function test and pAO2 imaging were performed on 4 nonsmokers (1 M, 3 F, 56 ± 1.7 years) and 4 smokers (3 M, 1 F, 52 ± 7.5 years) during three visits over the course of 2 weeks. Two measurements were performed per visit. Variability of pAO2 was assessed using a mixed-effect model, with an intraclass correlation coefficient calculated for each group. The coefficient of variation of pAO2 over the 3-day period was also compared with the coefficient of variation of pulmonary function test results.

Results

Short-term regional variability based on intraclass correlation coefficient was 0.71 for nonsmokers, and 0.63 for smokers, with long-term variability significantly lower at 0.59 and 0.47, respectively. While the coefficient of variation of the average pAO2 was similar to the repeatability of the diffusing capacity of CO, it was significantly higher than that of Forced Vital Capacity (P = 0.02).

Conclusion

Short-term and long-term pAO2 variability differences were used as an indication of true physiological changes in order to measure technical reproducibility. Smokers show higher physiologic variability and less technical reproducibility. The suggested pAO2-imaging technique showed a reasonable regional repeatability in nonsmokers as well as the ability to detect differences between the two groups with similar reproducibility and superior discriminatory ability when compared with pulmonary function tests. Magn Reson Med 70:1557–1566, 2013. © 2013 Wiley Periodicals, Inc.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.