Bone responses to rough titanium implants coated with biomimetic Ca-P in rabbit tibia
Fuming He
Department of Implantology, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Search for more papers by this authorGuoli Yang
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Search for more papers by this authorXiaoxiang Wang
Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027, China
Search for more papers by this authorCorresponding Author
Shifang Zhao
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, ChinaSearch for more papers by this authorFuming He
Department of Implantology, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Search for more papers by this authorGuoli Yang
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Search for more papers by this authorXiaoxiang Wang
Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027, China
Search for more papers by this authorCorresponding Author
Shifang Zhao
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, China
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatologic Hospital, College of Medical Sciences, Zhejiang University, Hangzhou 310006, ChinaSearch for more papers by this authorAbstract
A new technique to biomimetic deposition calcium phosphate (BDCaP) coating onto rough titanium substrates has been developed recently. This biomimetic deposition technique seems to be promising. It appears to have some advantages such as an inexpensive and simple set-up, and the possibility to synthesize layers with a defined surface morphology. The aim of this study was to examine the bone responses to BDCaP-coated implants in a rabbit model. Thirty one implants (16 BDCaP and 15 rough) were inserted into both tibia of 15 rabbits. After 2, 4, and 8 weeks following the implantation, the tibias were retrieved and prepared for histological evaluation. After 2 weeks, BDCaP-coated implant showed more bone ingrowth inside threads than the rough implants in medullary region (31.43% vs. 24.38%). Histological and quantitative histomorphometrical measurements demonstrated no more bone ingrowth and bone-implant contact for coated implant as compared with uncoated implant in cortical region at all experiment periods. From the histological viewpoint, the BDCaP coating did not have any positive effect on new bone formation. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2009
REFERENCES
- 1
Clemens JA,Klein CP,Vriesde RC,Rozing PM,de Groot K.
Healing of large (2 mm) gaps around calcium phosphate-coated bone implants: A study in goats with a follow-up of 6 months.
J Biomed Mater Res
1998;
40:
341–349.
10.1002/(SICI)1097-4636(19980605)40:3<341::AID-JBM1>3.0.CO;2-F CAS PubMed Web of Science® Google Scholar
- 2 Kuroda S,Virdi AS,Li P,Healy KE,Sumner DR. A low-temperature biomimetic calcium phosphate surface enhances early implant fixation in a rat model. J Biomed Mater Res A 2004; 70: 66–73.
- 3 Kokubo T,Kushitani H,Sakka S,Kitsugi T,Yamamuro T. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W. J Biomed Mater Res 1990; 24: 721–734.
- 4 Barrere F,van Blitterswijk CA,de Groot K,Layrolle P. Influence of ionic strength and carbonate on the Ca-P coating formation from SBFx5 solution. Biomaterials 2002; 23: 1921–1930.
- 5 de Groot K,Wolke JG,Jansen JA. Calcium phosphate coatings for medical implants. Proc Inst Mech Eng [H] 1998; 212: 137–147.
- 6 Barrere F,Layrolle P,van Blitterswijk CA,de Groot K. Biomimetic calcium phosphate coatings on Ti6AI4V: A crystal growth study of octacalcium phosphate and inhibition by Mg2+ and HCO3. Bone 1999; 25( 2 Suppl): 107S–111S.
- 7 Barrere F,Layrolle P,Van Blitterswijk CA,De Groot K. Biomimetic coatings on titanium: A crystal growth study of octacalcium phosphate. J Mater Sci Mater Med 2001; 12: 529–534.
- 8
Liu Y,Layrolle P,de Bruijn J,van Blitterswijk C,de Groot K.
Biomimetic coprecipitation of calcium phosphate and bovine serum albumin on titanium alloy.
J Biomed Mater Res
2001;
57:
327–335.
10.1002/1097-4636(20011205)57:3<327::AID-JBM1175>3.0.CO;2-J CAS PubMed Web of Science® Google Scholar
- 9 Habibovic P,Barrere F,van Blitterswijk CA,de Groot K,Layrolle P. Biomimetic hydroxyapatite coating on metal implants. J Am Ceram Soc 2002; 85: 517–522.
- 10 Barrere F,van BC,de Groot K,Layrolle P. Nucleation of biomimetic Ca-P coatings on ti6A14V from a SBF x 5 solution: influence of magnesium. Biomaterials 2002; 23: 2211–2220.
- 11 Liu Y,Li JP,Hunziker EB,de Groot K. Incorporation of growth factors into medical devices via biomimetic coatings. Philos Trans A Math Phys Eng Sci 2006; 364: 233–248.
- 12 Vasudev DV,Ricci JL,Sabatino C,Li P,Parsons JR. In vivo evaluation of a biomimetic apatite coating grown on titanium surfaces. J Biomed Mater Res A 2004; 69: 629–636.
- 13 Liu Y,de Groot K,Hunziker EB. Osteoinductive implants: The mise-en-scene for drug-bearing biomimetic coatings. Ann Biomed Eng 2004; 32: 398–406.
- 14 Liu Y,de Groot K,Hunziker EB. BMP-2 liberated from biomimetic implant coatings induces and sustains direct ossification in an ectopic rat model. Bone 2005; 36: 745–757.
- 15 Barrere F,van der Valk CM,Dalmeijer RA,Meijer G,van Blitterswijk CA,de Groot K,Layrolle P. Osteogenecity of octacalcium phosphate coatings applied on porous metal implants. J Biomed Mater Res A 2003; 66: 779–788.
- 16 Barrere F,van der Valk CM,Dalmeijer RA,van Blitterswijk CA,de Groot K,Layrolle P. In vitro and in vivo degradation of biomimetic octacalcium phosphate and carbonate apatite coatings on titanium implants. J Biomed Mater Res A 2003; 64: 378–387.
- 17 Barrere F,van der Valk CM,Meijer G,Dalmeijer RA,de Groot K,Layrolle P. Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats. J Biomed Mater Res B Appl Biomater 2003; 67: 655–665.
- 18 Yan WQ,Nakamura T,Kawanabe K,Nishigochi S,Oka M,Kokubo T. Apatite layer-coated titanium for use as bone bonding implants. Biomaterials 1997; 18: 1185–1190.
- 19
Yan WQ,Nakamura T,Kobayashi M,Kim HM,Miyaji F,Kokubo T.
Bonding of chemically treated titanium implants to bone.
J Biomed Mater Res
1997;
37:
267–275.
10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B CAS PubMed Web of Science® Google Scholar
- 20 He FM,Chen S,Liu L,Zhao SS,Sheng ZL,Wang XX. Experimental study of fast formation of biomimetic apatite coatings on pure titanium surface. Zhonghua Kou Qiang Yi Xue Za Zhi 2006; 41: 240–241.
- 21 He F,Liu L,Zhao S,Zhao S,Chen S,Wang X. Fast formation of biomimetic apatite coatings on pure porous titanium implant's surface. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 2007; 24: 806–811.
- 22 Fuming H,Guoli Y,Xiaoxiang W,Shifang Z. The removal torque of titanium implant inserted in rabbit femur coated with biomimetic deposited Ca-P coating. J Oral Rehabil 2008; 35: 754–765.
- 23 Yang GL,He FM,Zhao SS,Wang XX,Zhao SF. Effect of H2O2/HCl Heat Treatment of Implants on In Vivo Peri-implant Bone Formation. Int J Oral Maxillofac Implants 2008; 23: 1020–1028.
- 24 Lee JH,Ryu HS,Lee DS,Hong KS,Chang BS,Lee CK. Biomechanical and histomorphometric study on the bone-screw interface of bioactive ceramic-coated titanium screws. Biomaterials 2005; 26: 3249–3257.
- 25 Reigstad O,Franke-Stenport V,Johansson CB,Wennerberg A,Rokkum M,Reigstad A. Improved bone ingrowth and fixation with a thin calcium phosphate coating intended for complete resorption. J Biomed Mater Res B Appl Biomater 2007; 83: 9–15.
- 26 Dekker RJ,de Bruijn JD,Stigter M,Barrere F,Layrolle P,van Blitterswijk CA. Bone tissue engineering on amorphous carbonated apatite and crystalline octacalcium phosphate-coated titanium discs. Biomaterials 2005; 26: 5231–5239.
- 27 Takemoto M,Fujibayashi S,Neo M,Suzuki J,Kokubo T,Nakamura T. Bone-bonding ability of a hydroxyapatite coated zirconia-alumina nanocomposite with a microporous surface. J Biomed Mater Res A 2006; 78: 693–701.
- 28 Ekholm E,Tommila M,Forsback AP,Martson M,Holmbom J,Aaritalo V,Finnberg C,Kuusilehto A,Salonen J,Yli-Urpo A,Penttinen R. Hydroxyapatite coating of cellulose sponge does not improve its osteogenic potency in rat bone. Acta Biomater 2005; 1: 535–544.
- 29 Zagury R,Harari ND,Conz MB,Soares Gde A,Vidigal GMJr. Histomorphometric analyses of bone interface with titanium-aluminum-vanadium and hydroxyapatite-coated implants by biomimetic process. Implant Dent 2007; 16: 290–296.
- 30 Bernstein A,Nobel D,Mayr HO,Berger G,Gildenhaar R,Brandt J. Histological and histomorphometric investigations on bone integration of rapidly resorbable calcium phosphate ceramics. J Biomed Mater Res B Appl Biomater 2008; 84: 452–462.