Volume 31, Issue 6 pp. 1551-1560
research papers
Open Access

Mitigation of DMM-induced stripe patterns in synchrotron X-ray radiography through dynamic tilting

Mustapha Eddah

Mustapha Eddah

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 8.5: X-ray Imaging, Unter den Eichen 87, Berlin, 12205 Germany

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 5.4: Advanced Multi-Materials Processing, Unter den Eichen 87, Berlin, 12205 Germany

Search for more papers by this author
Henning Markötter

Corresponding Author

Henning Markötter

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 8.5: X-ray Imaging, Unter den Eichen 87, Berlin, 12205 Germany

Henning Markötter, e-mail: [email protected]Search for more papers by this author
Björn Mieller

Björn Mieller

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 5.4: Advanced Multi-Materials Processing, Unter den Eichen 87, Berlin, 12205 Germany

Search for more papers by this author
Michael Sintschuk

Michael Sintschuk

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 8.5: X-ray Imaging, Unter den Eichen 87, Berlin, 12205 Germany

Search for more papers by this author
Jörg Beckmann

Jörg Beckmann

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 8.5: X-ray Imaging, Unter den Eichen 87, Berlin, 12205 Germany

Search for more papers by this author
Giovanni Bruno

Giovanni Bruno

Bundesanstalt für Materialforschung und -prüfung (BAM), Division 8.5: X-ray Imaging, Unter den Eichen 87, Berlin, 12205 Germany

Search for more papers by this author
First published: 25 October 2024

Abstract

In synchrotron X-ray radiography, achieving high image resolution and an optimal signal-to-noise ratio (SNR) is crucial for the subsequent accurate image analysis. Traditional methods often struggle to balance these two parameters, especially in situ applications where rapid data acquisition is essential to capture specific dynamic processes. For quantitative image data analysis, using monochromatic X-rays is essential. A double multilayer monochromator (DMM) is successfully used for this aim at the BAMline, BESSY II (Helmholtz Zentrum Berlin, Germany). However, such DMMs are prone to producing an unstable horizontal stripe pattern. Such an unstable pattern renders proper signal normalization difficult and thereby causes a reduction of the SNR. We introduce a novel approach to enhance SNR while preserving resolution: dynamic tilting of the DMM. By adjusting the orientation of the DMM during the acquisition of radiographic projections, we optimize the X-ray imaging quality, thereby enhancing the SNR. The corresponding shift of the projection during this movement is corrected in post-processing. The latter correction allows a good resolution to be preserved. This dynamic tilting technique enables the homogenization of the beam profile and thereby effectively reduces noise while maintaining high resolution. We demonstrate that data captured using this proposed technique can be seamlessly integrated into the existing radiographic data workflow, as it does not need hardware modifications to classical X-ray imaging beamline setups. This facilitates further image analysis and processing using established methods.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.