Volume 136, Issue 25 47683
Article

Effect of different initiators on temperature-sensitive monolithic columns and application in online enrichment of β-sitosterol

Bin Guo

Bin Guo

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Search for more papers by this author
Huimin Wang

Huimin Wang

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Search for more papers by this author
Danan Lan

Danan Lan

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Search for more papers by this author
Xiaomin Pang

Xiaomin Pang

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Search for more papers by this author
Yiming Li

Yiming Li

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Search for more papers by this author
Haiyan Liu

Corresponding Author

Haiyan Liu

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Correspondence to: H. Y. Liu (E-mail: [email protected]) and L. G. Bai (E-mail: [email protected])Search for more papers by this author
Hongyuan Yan

Hongyuan Yan

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

College of Public Health, Hebei University, Baoding 071002, China

Search for more papers by this author
Ligai Bai

Corresponding Author

Ligai Bai

Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China

Correspondence to: H. Y. Liu (E-mail: [email protected]) and L. G. Bai (E-mail: [email protected])Search for more papers by this author
First published: 04 March 2019
Citations: 1

ABSTRACT

Three temperature-sensitive monolithic columns were prepared by atom transfer radical polymerization and oxidation–reduction method using the initiator systems of CCl4/FeCl2, BPO/DMA, and APS/TEMED, respectively. The three monoliths were characterized by scanning electron microscopy, nitrogen adsorption, and thermogravimetric analysis. The obtained monolithic columns were used as on-line solid phase extraction sorbent coupled with high-performance liquid chromatography for the enrichment of β-sitosterol. By comparing some influencing factors on the adsorption, the optimum temperature-sensitive monolithic column which was initiated by CCl4/FeCl2 was selected for enrichment of β-sitosterol from plant oil. The maximum adsorption capacity of the monolith for β-sitosterol was 10.0031 mg/g. The limit of detection and limit of quantitation were 0.039 and 0.13 mg/mL, respectively. The recovery was in the range of 90.21–98.26%. The results showed that the monolith had better selectivity for β-sitosterol and could be used for enrichment of β-sitosterol in food samples. © 2019 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47683.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.