Different degradation rates of nanofiber vascular grafts in small and large animal models
Takuma Fukunishi
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorChin Siang Ong
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorPooja Yesantharao
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorCameron A. Best
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorTai Yi
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorHuaitao Zhang
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorGunnar Mattson
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorJoseph Boktor
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorToshiharu Shinoka
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorChristopher K. Breuer
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorCorresponding Author
Narutoshi Hibino
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Correspondence
Narutoshi Hibino, Associate Professor of Surgery, Section of Cardiac Surgery, Department of Surgery, The University of Chicago Advocate Children's Hospital, 5841 S. Maryland Ave, Room E500B|MC5040, Chicago, IL 60637.
Email: [email protected]
Search for more papers by this authorTakuma Fukunishi
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorChin Siang Ong
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorPooja Yesantharao
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorCameron A. Best
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorTai Yi
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorHuaitao Zhang
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorGunnar Mattson
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorJoseph Boktor
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Search for more papers by this authorToshiharu Shinoka
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorChristopher K. Breuer
Center for Regenerative Medicine, Nationwide Children's Hospital, Columbus, OH
Search for more papers by this authorCorresponding Author
Narutoshi Hibino
Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, MD
Correspondence
Narutoshi Hibino, Associate Professor of Surgery, Section of Cardiac Surgery, Department of Surgery, The University of Chicago Advocate Children's Hospital, 5841 S. Maryland Ave, Room E500B|MC5040, Chicago, IL 60637.
Email: [email protected]
Search for more papers by this authorAbstract
Nanofiber vascular grafts have been shown to create neovessels made of autologous tissue, by in vivo scaffold biodegradation over time. However, many studies on graft materials and biodegradation have been conducted in vitro or in small animal models, instead of large animal models, which demonstrate different degradation profiles. In this study, we compared the degradation profiles of nanofiber vascular grafts in a rat model and a sheep model, while controlling for the type of graft material, the duration of implantation, fabrication method, type of circulation (arterial/venous), and type of surgery (interposition graft). We found that there was significantly less remaining scaffold (i.e., faster degradation) in nanofiber vascular grafts implanted in the sheep model compared with the rat model, in both the arterial and the venous circulations, at 6 months postimplantation. In addition, there was more extracellular matrix deposition, more elastin formation, more mature collagen, and no calcification in the sheep model compared with the rat model. In conclusion, studies comparing degradation of vascular grafts in large and small animal models remain limited. For clinical translation of nanofiber vascular grafts, it is important to understand these differences.
CONFLICT OF INTEREST
Drs. Breuer and Shinoka receive research support from Gunze Ltd. (Kyoto, Japan) and Cook Regentec (Indianapolis, IN). Dr. Breuer is on the Scientific Advisory Board of Cook Medical (Bloomington, IN). Dr. Hibino receives research support from Secant Medical (Telford, PA). Jed Johnson is a co-founder of Nanofiber Solutions, Inc. (Hilliard, OH). Cameron Best and Dr. Breuer are co-founders of LYST Therapeutics, LLC (Columbus, OH). The remaining authors have no conflicts of interest to disclose.
Supporting Information
Filename | Description |
---|---|
TERM2977 supp-0001-FigureS1.TIFTIFF image, 985.7 KB |
Figure S1: Nanofiber vascular graft luminal diameter over time by ultrasonography The luminal diameters (mm) of PCL/CS vascular grafts are plotted in gray and the luminal diameters (mm) of PGA/PLCL vascular grafts are plotted in black. |
Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
REFERENCES
- Benrashid, E., McCoy, C. C., Youngwirth, L. M., Kim, J., Manson, R. J., Otto, J. C., & Lawson, J. H. (2016). Tissue engineered vascular grafts: Origins, development, and current strategies for clinical application. Methods, 99, 13–19.
- Brennan, M. P., Dardik, A., Hibino, N., Roh, J. D., Nelson, G. N., Papademitris, X., … Breuer, C. K. (2008). Tissue-engineered vascular grafts demonstrate evidence of growth and development when implanted in a juvenile animal model. Annals of Surgery, 248, 370–377.
- Campbell, J. H., Efendy, J. L., & Campbell, G. R. (1999). Novel vascular graft grown within recipient's own peritoneal cavity. Circulation Research, 85, 1173–1178.
- Campbell, J. H., Efendy, J. L., Han, C., Girjes, A. A., & Campbell, G. R. (2000). Haemopoietic origin of myofibroblasts formed in the peritoneal cavity in response to a foreign body. Journal of Vascular Research, 37, 364–371.
- Campbell, J. H., Walker, P., Chue, W.-L., Daly, C., Cong, H.-L., Xiang, L., & Campbell, G. R. (2004). Body cavities as bioreactors to grow arteries. International Congress Series, 1262, 118–121.
10.1016/j.ics.2003.11.022 Google Scholar
- Dahl, S. L. M., Kypson, A. P., Lawson, J. H., Blum, J. L., Strader, J. T., Li, Y., … Niklason, L. E. (2011). Readily available tissue-engineered vascular grafts. Science Translational Medicine, 3, 68ra9–68ra9.
- Davies, L. C., & Taylor, P. R. (2015). Tissue-resident macrophages: Then and now. Immunology, 144, 541–548.
- Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011). Polymeric scaffolds in tissue engineering application: A review. International Journal of Polymer Science, 2011, 1–19.
- Fukunishi, T., Best, C., Ong, C. S., Groehl, T., Reinhardt, J., Yi, T., … Hibino, N. (2017). Role of bone marrow mononuclear cell seeding for nanofiber vascular grafts. Tissue Engineering. Part A.
- Fukunishi, T., Best, C. A., Sugiura, T., Opfermann, J., Ong, C. S., Shinoka, T., … Hibino, N. (2017). Preclinical study of patient-specific cell-free nanofiber tissue-engineered vascular grafts using 3-dimensional printing in a sheep model. The Journal of Thoracic and Cardiovascular Surgery, 153, 924–932.
- Fukunishi, T., Best, C. A., Sugiura, T., Shoji, T., Yi, T., Udelsman, B., … Hibino, N. (2016). Tissue-engineered small diameter arterial vascular grafts from cell-free nanofiber PCL/Chitosan scaffolds in a sheep model. PLoS ONE, 11, e0158555.
- Heron, M. (2016). Deaths: Leading causes for 2013. National Vital Statistics Reports, 65, 1–95.
- Hibino, N., Villalona, G., Pietris, N., Duncan, D. R., Schoffner, A., Roh, J. D., … Breuer, C. K. (2011). Tissue-engineered vascular grafts form neovessels that arise from regeneration of the adjacent blood vessel. The FASEB Journal, 25, 2731–2739.
- Jiminez, J. A., Uwiera, T. C., Douglas Inglis, G., & Uwiera, R. R. E. (2015). Animal models to study acute and chronic intestinal inflammation in mammals. Gut Pathogens, 7, 29.
- Johnson, J., Niehaus, A., Nichols, S., Lee, D., Koepsel, J., Anderson, D., & Lannutti, J. (2009). Electrospun PCL in vitro: A microstructural basis for mechanical property changes. Journal of Biomaterials Science. Polymer Edition, 20, 467–481.
- Kurobe, H., Maxfield, M. W., Breuer, C. K., & Shinoka, T. (2012). Concise review: tissue-engineered vascular grafts for cardiac surgery: Past, present, and future. Stem Cells Translational Medicine, 1, 566–571.
- L'Heureux, N., Dusserre, N., Konig, G., Victor, B., Keire, P., Wight, T. N., … McAllister, T. N. (2006). Human tissue-engineered blood vessels for adult arterial revascularization. Nature Medicine, 12, 361–365.
- Liu, R. H., Ong, C. S., Fukunishi, T., Ong, K., & Hibino, N. (2018). Review of vascular graft studies in large animal models. Tissue Engineering. Part B, Reviews, 24, 133–143.
- Melchiorri, A. J., Hibino, N., & Fisher, J. P. (2013). Strategies and techniques to enhance the in situ endothelialization of small-diameter biodegradable polymeric vascular grafts. Tissue Engineering. Part B, Reviews, 19, 292–307.
- Milani-Nejad, N., & Janssen, P. M. (2014a). Small and large animal models in cardiac contraction research: Advantages and disadvantages. Pharmacology & Therapeutics, 141, 235–249.
- Milani-Nejad, N., & Janssen, P. M. L. (2014b). Small and large animal models in cardiac contraction research: Advantages and disadvantages. Pharmacology & Therapeutics, 141, 235–249.
- Nelson, M. T., Johnson, J., & Lannutti, J. (2014). Media-based effects on the hydrolytic degradation and crystallization of electrospun synthetic-biologic blends. Journal of Materials Science. Materials in Medicine, 25, 297–309.
- O'Brien, F. J. (2011). Biomaterials & scaffolds for tissue engineering. Materials Today, 14, 88–95.
- Ong, C. S., Zhou, X., Huang, C. Y., Fukunishi, T., Zhang, H., & Hibino, N. (2017). Tissue engineered vascular grafts: Current state of the field. Expert Review of Medical Devices, 14, 383–392.
- Patten, R. D., & Hall-Porter, M. R. (2009). Small animal models of heart failure. Development of Novel Therapies, Past and Present, 2, 138–144.
- Preis, M., Schneiderman, J., Koren, B., Ben-Yosef, Y., Levin-Ashkenazi, D., Shapiro, S., … Flugelman, M. Y. (2016). Co-expression of fibulin-5 and VEGF165 increases long-term patency of synthetic vascular grafts seeded with autologous endothelial cells. Gene Therapy, 23, 237–246.
- Roh, J. D., Brennan, M. P., Lopez-Soler, R. I., Fong, P. M., Goyal, A., Dardik, A., & Breuer, C. K. (2007). Construction of an autologous tissue-engineered venous conduit from bone marrow-derived vascular cells: Optimization of cell harvest and seeding techniques. Journal of Pediatric Surgery, 42, 198–202.
- Roh, J. D., Nelson, G. N., Brennan, M. P., Mirensky, T. L., Yi, T., Hazlett, T. F., … Breuer, C. K. (2008). Small-diameter biodegradable scaffolds for functional vascular tissue engineering in the mouse model. Biomaterials, 29, 1454–1463.
- Roh, J. D., Sawh-Martinez, R., Brennan, M. P., Jay, S. M., Devine, L., Rao, D. A., … Breuer, C. K. (2010). Tissue-engineered vascular grafts transform into mature blood vessels via an inflammation-mediated process of vascular remodeling. Proceedings of the National Academy of Sciences, 107, 4669–4674.
- Schwarz, E. R., Pollick, C., Dow, J., Patterson, M., Birnbaum, Y., & Kloner, R. A. (1998). A small animal model of non-ischemic cardiomyopathy and its evaluation by transthoracic echocardiography. Cardiovascular Research, 39, 216–223.
- Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., … Tompkins, R. G. (2013). Genomic responses in mouse models poorly mimic human inflammatory diseases. Proceedings of the National Academy of Sciences, 110(9), 3507–3512.
- Sugiura, T., Lee, A. Y., & Shinoka, T. (2017). Tissue engineering in vascular medicine. In A. U. Rahman & S. Anjum (Eds.), Frontiers in stem cell and regenerative medicine research. United Arab Emirates: Bentham Science Publishers.
10.2174/9781681084756117050003 Google Scholar