An antioxidant stabilized, chemically cross-linked UHMWPE with superior toughness
Corresponding Author
Ebru Oral
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Correspondence to: Ebru Oral; e-mail: [email protected]Search for more papers by this authorKeith K. Wannomae
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorDavid A. Bichara
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Search for more papers by this authorBrad Micheli
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorBrinda N. Doshi
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorCaitlin O'Brien
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorG. Petur Nielsen
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Bone and Soft Tissue Pathology, Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorOrhun K. Muratoglu
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Search for more papers by this authorCorresponding Author
Ebru Oral
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Correspondence to: Ebru Oral; e-mail: [email protected]Search for more papers by this authorKeith K. Wannomae
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorDavid A. Bichara
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Search for more papers by this authorBrad Micheli
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorBrinda N. Doshi
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorCaitlin O'Brien
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorG. Petur Nielsen
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Bone and Soft Tissue Pathology, Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts
Search for more papers by this authorOrhun K. Muratoglu
Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts
Search for more papers by this authorAbstract
Chemical cross-linking of ultrahigh molecular weight polyethylene (UHMWPE) using an organic peroxide followed by high temperature melting results in a large increase in toughness accompanied by a decrease in cross-link density, which, surprisingly does not compromise the wear resistance. We compared the mechanical properties and wear behavior of a vitamin E blended, chemically cross-linked and high temperature melted UHMWPE produced by ram extrusion (PRX HTM) to those measured with the clinically available 100-kGy irradiated and melted UHMWPE (CISM 100). We also assessed the local biocompatibility of PRX-HTM in rabbit subcutaneous pouch and osteochondral defect models. The ultimate tensile strength and pin-on-disc wear rate were similar to CISM 100; whereas the elongation-at-break and impact toughness were much higher with PRX-HTM. The stress intensity factor range at crack inception was also higher with PRX-HTM. Accelerated aging did not result in any measurable oxidation or changes in mechanical properties. Hip simulator wear rate of acetabular liners made with PRX-HTM was 0.3 ± 0.4 mg/million-cycle, similar to that reported for CISM 100 liners. The wear particles were largely spherical with a number-averaged particle size of 0.95 μm with ~75% of particles below 1 μm. The subcutaneous and osteochondral rabbit implantations showed no histological differences between PRX-HTM and the control CISM 100. Pre-clinical wear, mechanical, and biocompatibility testing of PRX HTM showed feasibility for the use of this material as a total joint arthroplasty implant bearing surface. This process has the potential of eliminating the additional step of radiation cross-linking by combining consolidation and cross-linking while improving toughness. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1945–1952, 2019.
REFERENCES
- 1Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH, Gul R, McGarry F. Unified Wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 1999; 20(16): 1463–1470.
- 2Registry CJR. Hip and Knee replacements in Canada. 2007 Annual report: CANA Insitute for Health Information; 2007.
- 3Kurtz S, Gawel H, Patel J. History and systematic review of Wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 2011; 469: 2262–2277.
- 4de Steiger R, Muratoglu O, Lorimer M, Ciuthbert A, Graves S. Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty. Acta Orthop 2015; 866: 1–7.
- 5Charlesby A. Cross-linking of polythene by pile radiation. Proc Roy Soc Lond 1952; A215: 187–215.
- 6DuPlessis T, Grobbelaar C, Marais F. The improvement of polyethylene prostheses through radiation crosslinking. Radiat Phys Chem 1977; 9: 647–652.
- 7de Boer J, van den Berg H, Pennings A. Crosslinking of ultra-high molecular weight polyethylene in the oriented state with diculylperoxide. Polymer 1983; 25: 513–519.
- 8Gul R. The effects of peroxide content on the wear behavior, microstructure and mechanical properties of peroxide cross-linked UHMWPE used in total hip replacement. J Mater Sci Mater Med 2008; 19(6): 2427–2435.
- 9Atkinson JR, Cicek RZ. Silane crosslinked polyethylene for prosthetic applications. Part I. certain physical and mechanical properties related to the nature of the material. Biomaterials 1983; 4: 267–275.
- 10Atkinson JR, Cicek RZ. Silane crosslinked polyethylene for prosthetic applications. Part II. Creep and wear behavior and a preliminary molding test. Biomaterials 1984; 5: 326–335.
- 11Muratoglu OK, Merrill EW, Bragdon CR, O'Connor DO, Hoeffel D, Burroughs B, Jasty M, Harris WH. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res 2003; 417: 253–262.
- 12Bracco P, Oral E. Vitamin E-stabilized UHMWPE for total joint implants. Clin Orthop Relat Res 2011; 469: 2286–2293.
- 13Oral E, Christensen S, Malhi A, Wannomae K, Muratoglu O. Wear resistance and mechanical properties of highly crosslinked UHMWPE doped with vitamin E. J Arthroplasty 2006; 21(4): 580–591.
- 14Oral E, Wannomae KK, Hawkins NE, Harris WH, Muratoglu OK. A-Tocopherol doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials 2004; 25(24): 5515–5522.
- 15Shibata N, Tomita N. The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance. Biomaterials 2005; 26(29): 5755–5762.
- 16Bracco P, Brunella V, Zanetti M, Luda MP, Costa L. Stabilisation of ultra-high molecular weight polyethylene with vitamin E. Polym Degrad Stab 2007; 92: 2155–2162.
- 17Kurtz S, Dumbleton J, Siskey R, Wang A, Manley M. Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation. J Biomed Mater Res 2008; 90A: 549–563.
- 18Rowell S, Oral E, Muratoglu O. Three-year real-time aging of vitamin E-diffused, radiation cross-linked UHMWPE. 2009; Las Vegas, NV.
- 19Lerf R, Zurbrugg D, Delfosse D. Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials 2010; 31: 3643–3648.
- 20Wannomae K, Christensen C, Micheli B, Rowell S, Schroeder D, OK M. Delamination and adhesive wear behavior of alpha-tocopherol-stabilized irradiated UHMWPE. J Arthroplasty 2010; 25(4): 635–643.
- 21Banche G, Bracco P, Bistolfi A, Allizond V, Boffano M, Costa L, Cimino A, Cuffini A, Brach del Prever E. Vitamin E blended UHMWPE may have the potential to reduce bacterial adhesive ability. J Orthop Res 2011; 29(11): 1662–1667.
- 22Haider H, Weisenburger J, Kurtz S, Rimnac C, Freedman J, Schroeder D, Garvin K. Does vitamin E-stabilized UHMWPE address concerns of cross-linked polyethylene in total knee arthroplasty. J Arthroplasty 2012; 27(3): 461–469.
- 23Bragdon C, Grrene M, Rubash H, Freiberg A, Malchau H. RSA evaluation of wear of vitamin E-stabilized highly cross-linked polyethylene. 2010; Gothenburg, Sweden.
- 24Greene M, Sillesen N, Nebergall A, Rubash H, Kwon Y-M, Bragdon C, Malchau H. RSA Evaluation of vitamin E diffused highly crosslinked polyethylene and acetabular and femoral component stability. Chicago, IL: Annual Meeting of the American Academy of Orthopaedic Surgeons; 2013. p. 560.
- 25Lindalen E, Nordsletten L, Hovik O, Rohrl S. E-vitamin infused highly cross-linked polyethylene: RSA results from a randomised controlled trial using 32 mm and 36 mm ceramic heads. Hip Int 2015; 25(1): 50–55.
- 26Oral E, Godleski Beckos C, Malhi A, Muratoglu O. The effects of high dose irradiation on the cross-linking of vitamin E-blended UHMWPE. Biomaterials 2008; 29: 3557–3560.
- 27Oral E, Neils A, Rowell S, Lozynsky A, Muratoglu O. Increasing irradiation temperature maximizes vitamin E grafting and wear resistance of UHMWPE. Biomaterials 2013; 101B(3): 436–440.
- 28Oral E, Doshi B, Gul R, Neils A, Kayandan S, Muratoglu O. Peroxide cross-linked UHMWPE blended with vitamin E. J Biomed Mater Res 2016; 104B: 316–322.
- 29Fu J, Ghali B, Lozynsky A, Oral E, Muratoglu O. Ultrahigh molecular weight polyethylene with improved plasticity and toughness by high temperature melting. Polymer 2010; 51(12): 2721–2731.
- 30Doshi B, Fu J, Oral E, Muratoglu O. Vitamin E can be used to hinder scissioning in radiation cross-linked UHMWPE during high temperature melting. J Appl Polym Sci 2015; 132(42735): 1–8.
- 31Doshi B, Fung K, Oral E, Muratoglu O. A wear and highly oxidation resistant chemically cross-linked UHMWPE with improved toughness. Orthop Proc 2017; 99-B: 39.
- 32Peacock A. Production processes. handbook of polyethylene: structure, properties and applications. New York: Marcel Dekker Inc.; 2000. pp. 43–66.
- 33Kurtz S. From ethylene gas to UHMWPE component: the process of producing Orthopaedic implants. In: S Kurtz, editor. UHMWPE Biomaterials Handbook. New York: Elsevier; 2009. pp. 7–19.
10.1016/B978-0-12-374721-1.00002-X Google Scholar
- 34Bragdon CR, O'Connor DO, Lowenstein JD, Jasty M, Biggs SA, Harris WH. A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty. J Arthroplasty 2001; 16(5): 658–665.
- 35Bichara D, Malchau E, Sillesen N, Cakmak S, Nielsen G, Muratoglu O. Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. J Arthroplasty 2014; 29(Suppl. 2): 232–237.
- 36Langlois J, Zaoui A, Bichara D, Nich C, Bendishoum M, Petite H, Muratoglu O, Hamadouche M. Biological reaction to polyethylene particles in a murine calvarial model is highly influenced by age. J Orthop Res 2016; 34(4): 574–580.
- 37Harris W. The problem is osteolysis. J Biomed Mater Res 1996; 31: 19–26.
- 38Registry AJR. Annual report on hip and knee arthroplasty data (2015). Rosemont, IL: American Joint Replacement Registry; 2016.
- 39Wright TM, Astion DJ, Bansal M, Rimnac CM, Insall JN, Robinson RP. Failure of carbon fiber-reinforced polyethylene total knee-replacement components. J Bone Joint Surg 1988; 70-A: 926–932.
- 40Costa L, Jacobson K, Bracco P, Brach del Prever EM. Oxidation of orthopaedic UHMWPE. Biomaterials 2002; 23: 1613–1624.
- 41Rowell S, Oral E, Muratoglu O. Comparative oxidative stability of alpha-tocopherol blended and diffused UHMWPEs at 3 years of real-time aging. J Orthop Res 2009; 29: 773–780.
- 42Oral E, Neils A, Lyons C, Fung M, Doshi B, Muratoglu O. Surface cross-linked UHMWPE can enable the use of larger femoral heads in total joints. J Orthop Res 2013; 31(1): 59–66.
- 43Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J. Bone Joint Surg Am 2007; 89(10): 2212–2217.
- 44Muratoglu O, Mark A, Vittetoe D, Harris W, Rubash H. Polyethylene damage in total knees and use of highly crosslinked polyethylene. J Bone Joint Surg 2003; 85-A(Supplement 1): 7–13.
- 45Doshi B, Ward J, Oral E, Muratoglu O. The fatigue toughness of irradiated vitamin E/UHMWPE blends. J Orthopaed Res 2016; 34(9): 1514–1520.
- 46Green T, Fisher J, Stone M, Wroblewski B, Ingham E. Polyethylene particles of a critical size are necessary for the induction of cytokines by macrophages in vitro. Biomaterials 1998; 19(24): 2297–2302.
- 47Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng H – J Eng Med 2000; 214(H1): 21–37.
- 48Endo M, Tipper J, Barton D, Stone M, Ingham E, Fisher J. Comparison of wear, wear debris and functional biological activity of moderately cross-linked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng H – J Eng Med 2002; 216(H2): 111–122.