Volume 107, Issue 6 pp. 1945-1952
Original Research Reports

An antioxidant stabilized, chemically cross-linked UHMWPE with superior toughness

Ebru Oral

Corresponding Author

Ebru Oral

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts

Correspondence to: Ebru Oral; e-mail: [email protected]Search for more papers by this author
Keith K. Wannomae

Keith K. Wannomae

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Search for more papers by this author
David A. Bichara

David A. Bichara

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts

Search for more papers by this author
Brad Micheli

Brad Micheli

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Search for more papers by this author
Brinda N. Doshi

Brinda N. Doshi

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Search for more papers by this author
Caitlin O'Brien

Caitlin O'Brien

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Search for more papers by this author
G. Petur Nielsen

G. Petur Nielsen

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Bone and Soft Tissue Pathology, Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts

Search for more papers by this author
Orhun K. Muratoglu

Orhun K. Muratoglu

Harris Orthopedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts

Department of Orthopedic Surgery, Harvard Medical School, Boston, Massachusetts

Search for more papers by this author
First published: 26 December 2018
Citations: 15

Abstract

Chemical cross-linking of ultrahigh molecular weight polyethylene (UHMWPE) using an organic peroxide followed by high temperature melting results in a large increase in toughness accompanied by a decrease in cross-link density, which, surprisingly does not compromise the wear resistance. We compared the mechanical properties and wear behavior of a vitamin E blended, chemically cross-linked and high temperature melted UHMWPE produced by ram extrusion (PRX HTM) to those measured with the clinically available 100-kGy irradiated and melted UHMWPE (CISM 100). We also assessed the local biocompatibility of PRX-HTM in rabbit subcutaneous pouch and osteochondral defect models. The ultimate tensile strength and pin-on-disc wear rate were similar to CISM 100; whereas the elongation-at-break and impact toughness were much higher with PRX-HTM. The stress intensity factor range at crack inception was also higher with PRX-HTM. Accelerated aging did not result in any measurable oxidation or changes in mechanical properties. Hip simulator wear rate of acetabular liners made with PRX-HTM was 0.3 ± 0.4 mg/million-cycle, similar to that reported for CISM 100 liners. The wear particles were largely spherical with a number-averaged particle size of 0.95 μm with ~75% of particles below 1 μm. The subcutaneous and osteochondral rabbit implantations showed no histological differences between PRX-HTM and the control CISM 100. Pre-clinical wear, mechanical, and biocompatibility testing of PRX HTM showed feasibility for the use of this material as a total joint arthroplasty implant bearing surface. This process has the potential of eliminating the additional step of radiation cross-linking by combining consolidation and cross-linking while improving toughness. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1945–1952, 2019.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.