Volume 27, Issue 3 pp. 546-550
Full Paper

Simultaneous Spectrophotometric Determination of Three Tolualdehyde Isomers by Artificial Neural Networks and Its Comparison with Partial Least Squares

Huiwen FANG

Huiwen FANG

Tel.: 0086-0311-83030908; Fax: 0086-0311-83992168

Search for more papers by this author
Hui LI

Hui LI

China National Center for Quality Supervision and Test of Environmental Protection Products, Hebei Food Safety Laboratory, Shijiazhuang, Hebei 050051, China

Search for more papers by this author
Yanwei LI

Yanwei LI

College of Chemistry and Chemical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024, China

Search for more papers by this author
Jing ZHAO

Jing ZHAO

College of Chemistry and Chemical Engineering, University of Guangxi, Nanning, Guangxi 530004, China

Search for more papers by this author
Jian XU

Jian XU

College of Chemistry and Chemical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024, China

Search for more papers by this author
First published: 02 April 2009
Citations: 1

Abstract

The simultaneous determination of tolualdehyde isomer mixtures by using a spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interference. By multivariate calibration methods, such as partial least squares (PLS) and artificial neural network (ANN), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. The ANN calibration model of simultaneous determination of tolualdehyde isomers was based on absorption spectra in the 230–304 nm range for 48 different mixtures of tolualdehyde isomers, and the concentration ranges for o-tolualdehyde, m-tolualdehyde and p-tolualdehyde were 6.0–15.0, 7.0–16.0 and 8.0–19.0 µg·mL−1, respectively. Other 7 samples were applied to testing the predictive ability of the calibration model. The effect of the three isomers with different concentration ratios in their mixtures on the accuracy of determination results was discussed and the appropriate range of concentration ratio was found. The proposed method was applied to simultaneous determination of the three isomers in synthetic samples and the recoveries were between 84.00% and 109.60%. The results of determination were compared with the PLS model without significant difference at 0.05 level for o-tolualdehyde and m-tolualdehyde by paired t-test. But a better performance for p-tolualdehyde in their mixtures could be obtained by the ANN calibration model.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.