This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent
reduced horizontal spot sizes on samples, and good speckle contrast.1. Introduction
Synchrotron light sources produce partially coherent light that has enabled new techniques
such as X-ray photon correlation spectroscopy (XPCS) to flourish into mature material
characterization methods (Sutton, 2008; Livet & Sutton, 2012
; Sinha et al., 2014
; Sandy et al., 2018
). Due to the large mismatch between the horizontal and vertical source size in third-generation
synchrotron sources, which is typically a factor of 20 larger in the horizontal direction,
the coherence length is a factor of 20 smaller in the horizontal than in the vertical
direction. As a result, beamlines specializing in XPCS often focus the vertical coherent
fan to match the smaller horizontal coherence length on the sample (Sandy et al., 2010
; Chsuhkin, 2020
).
Beamline 8-ID currently focuses the vertical coherent ).
For some experiments on beamline 8-ID, one would like to use a 2D focusing compound refractive lens (CRL) with similar focal length as the existing 1-ID lens to produce a beam that better matches the micro-structure of materials. Focusing on a small spot size also produces larger speckle sizes which can be better suited for a large-pixel pixel array detector (PAD) with typical pixel size of 0.1 mm. One would like to illuminate the sample with a 2D focused coherent beam, so, to achieve this, naively, one would reduce the horizontal beam size in the upstream hutch 8-ID-A with a slit to illuminate the lens coherently.
By choosing an appropriately small size of the horizontal slit, the diffracted beam will fill the lens with transversely coherent light. The
will be reduced, but with the proper slit the optics will produce a diffraction-limited spot size.We note that using a slit as a spatial filter is a well known technique at synchrotrons.
It is used on the X-ray Nanoprobe for example at the APS (Winarski et al., 2012). On that beamline, a horizontal mirror focuses the horizontal fan of the source
onto a beam-defining aperture that filters a coherent fan of light for the X-ray optics.
This aperture produces a secondary horizontal source and should be placed as close
as possible to the source. It enables the production of round beams on the sample
after focusing with a short focal length zone plate.
Experimenters at the Petra III beamline P10 routinely use two-dimensionally focused
beams in coherent diffraction experiments (Zozulya et al., 2012). Due to the very small horizontal source size at this facility, one can focus horizontally
50–100 µm beams coherently to a few µm on the sample without closing any near front-end
horizontal slit. This type of source spatial filtering allows one to deliver round
focused coherent beams at existing synchrotrons with modest horizontal transverse
coherent lengths (10 µm or below).
Recently, several authors have modeled the propagation of coherence through optical
systems including refractive lenses (Singer & Vartanyants, 2014; Schroer & Falkenberg, 2014
). The first paper provides an analytical treatment which includes a slit placed just
upstream of the lens and shows its impact to control the focal coherence length and
spot size (Singer & Vartanyants, 2014
). This can be applied to the vertical focusing direction in this paper, although
it approximates the slit by a Gaussian aperture. Since it does not include a treatment
adding the horizontal secondary slit, we choose to simulate our results with advanced
ray-tracing simulations.
Several ray-tracing approaches have been developed which include the propagation of
coherence through optical elements from a synchrotron (Chubar et al., 2013; Shi et al., 2014
; Wiegart et al., 2019
). The work of Wiegart et al. (2019
) is noteworthy for comparing measured coherent diffraction patterns from a thin grating
sample illuminated by the 11-ID beamline of the National Synchrotron Light Source
with simulations from the Synchrotron Radiation Workshop software (Chubar et al., 2013
). The paper also describes the optical scheme of the beamline which focuses the beam
in two dimensions with a vertical transfocator upstream in the optics hutch and a
horizontal kineform lens in the experimental hutch (Wiegart et al., 2019
).
In this paper we present a demonstration of 2D focusing with a long-focal-length Be
lens to produce a round beam. We report the speckle size and contrast measured with
focused coherent light. We present also optical simulations performed with a hybrid
coherent diffraction module (Shi et al., 2014).
2. Optical modeling
The basic concept is to use a slit as a coherence filter in the horizontal direction so that its diffraction pattern in the lens plane matches the vertical transverse coherence length at the lens location. The lens can then be coherently illuminated by placing just upstream of the lens a square aperture with an opening equal to the vertical transverse coherence length
where Σy is the root-mean-square (RMS) vertical source size, and Rl is the distance source–lens (Dierker, 1997; Dufresne et al., 2002
). The distance Rl is shown in Fig. 1
. The factor
comes from the definition of the transverse coherence length for a Gaussian incoherent
source from the Van Cittert–Zernicke theorem (Goodman, 1985
; Dierker, 1997
).
![]() |
Figure 1 The horizontal rays collimation geometry. |
Then, a horizontal slit placed upstream of the lens with an opening Δ will produce a diffraction pattern with a full width at half-maximum (FWHM) approximately equal to
where Rs is the distance from the source to the upstream horizontal slit. The factor 0.886 comes from the FWHM of the Fraunhofer diffraction pattern of a 1D aperture with opening Δ. If one assumes that the horizontal source is spatially uniform at the white-beam slit and incoherent, the horizontal transverse coherence length at the lens is
using the definition found in Goodman (1985).
Assuming that the undulator source is Gaussian in spatial and angular emission, the
RMS horizontal beam size at a distance Rs from the source is approximately equal to , where
is the source horizontal divergence and Σx the source size. The X-ray source divergence is
where = (0.5λ/L)1/2 is the single electron source divergence through an undulator of length L, and
is the electron bunch RMS divergence. The X-ray vertical source size,
is the convolution of the single electron source size σr = (2λL)1/2/(2π) and the RMS electron beam size σey, so there is a 6% correction for hard X-rays of 1 Å for a L = 2.4 m-long undulator (Elleaume, 2002). A similar equation to equation (5)
can be written in the horizontal direction for Σx, but the energy dependence is negligible due to the much larger electron beam size
σex, thus Σx ≃ σex.
We note that the Δ/Rs, when
Σx. The horizontal beam size at the APS becomes dominated by the horizontal divergence
for distances larger than
≃ 22 m (see Table 1
), which is upstream of the front-end.
|
Putting equation (1) into equation (2)
, one finds
It is fairly independent of wavelength if one neglects the small energy dependence of the source size. The throughput from slitting the horizontal can be approximated by
where ϕ is the partially coherent transmitted through the slit, assuming the slit opening Δ is much smaller than the beam profile at the slit position. By inspection of equation
(7), Δ is largest when Rs = 0, and the beam size is also the smallest, thus the defining slit should be as
close as possible to the source to optimize the At the APS, white-beam slits are located after the front-end, but at some synchrotrons
they are accessible before the front-end (Wiegart et al., 2019
). Reducing the horizontal beam also reduces the power on X-ray optics downstream
of the slit.
At the APS, the RMS horizontal and vertical electron beam size are, respectively,
σex = 0.275 mm and σey ≃ 0.010 mm, so they differ by a factor of 27. For a ratio Rs/Rl ≃ 1/2, the small opening Δ will reduce the source divergence such that the main contribution is the pinhole
camera of the source through the aperture ≃ Σx/Rs, thus for Rs = 27 m,
= 10 µrad. We note that, from equation (4)
,
≃ 13.5 µrad at 11 keV.
The RMS beam size at the lens position will be the convolution of the diffraction pattern of the slit Δ and beam size propagated through the aperture. Assuming that the source irradiance is both Gaussian in space and angular emission, one can show that the RMS beam profile at the lens should be written as
The first term is derived in Appendix A and comes from the pinhole camera image of the horizontal source with finite source
size and divergence. The second term on the sum in equation (8)
is the width of the diffraction pattern of the slit with opening Δ. We note that an exact treatment is discussed for a bending magnet pinhole camera
diagnostic (Yang et al., 2017
) including Fresnel diffraction. This is not needed as we are in the far-field of
the slit.
Looking back at Fig. 1, one can show that the two slits form a collimator with collimation angle
where Δl is the slit opening in front of the lens. This collimator limits the size of the source to a perceived horizontal size
Using values found in Table 1 for the distances, and white-beam slit opening Δ, while using Δl = 0.125 mm, one finds Δx = 0.138 mm. Using equation (3)
, this collimation increases the source transverse coherence length at the white-beam
slit to
= λRs/Δx = 23 µm for values defined in Table 1
and used in this paragraph. In this example,
= 71.5%, which is an improvement from the original ratio lx/Δ ≃ 10% in Table 1
.
The focal length of a parabolic compound refractive lens in the thin lens approximation is given by
where R is the radius of curvature of a lenslet, N is the number of lenslets, and δ is the index of refraction decrement (Snigirev et al., 1996; Lengeler et al., 2002
). When the lens can view the full source, if the source–lens distance Rl
f, we expect the RMS focal spot size to be a demagnified image of the source with σi ≃ fΣs/Rl, where Σs is the RMS source size.
If we use a small white-beam slit opening instead, then a rough estimate of the focal spot size is
where wd = 0.886λ(Re − Rl)/Δl, which is the FWHM of the diffraction pattern of the lens slit aperture at the focal
distance Re measured from the source. In equation (12), the demagnified source image width,
In equation (13), we use the white-beam slit opening as the source for the demagnified horizontal
source width. For values found in Table 1
, we find the FWHM horizontal spot size w = 2.6 µm.
We define the depth of focus as the distance Δz from the best focal plane such that the FWHM of the beam is
where wm is the computed focal spot in equation (12). One finds
Note that wm depends on Δl, the slit opening before the lens. Using the vertical minimum focus, wm = 2.0 µm, the vertical depth of focus is Δz = 3.7 cm.
3. X-ray optical simulations
X-ray optical simulations were performed with Shadow using the Hybrid method reported by Shi et al. (2014). The X-ray energy was set to 11.0 keV so that the focal distances would match the
experimental setup described in Table 1
. The two-dimensional aperture set to 0.125 mm × 0.125 mm is placed 59 cm before the
lens. Fig. 2
shows the simulation results in the plane with the best vertical focus of a 2D Be
lens. The focal spot size in the horizontal and vertical direction is shown in the
plot legend as well as the transmission of the optical system of 0.059%. We note that
clear diffraction effects are noticeable in the vertical direction due to the fact
that the transverse coherence length vertically is larger than Δl = 0.125 mm.
![]() |
Figure 2 Simulated focal spot profile in 8-ID-I with a white-beam slit opening of 32 µm, 2.29 m from the lens. The central part of the figure shows the intensity distribution. The two graphs above and at the right in the figure show the cumulative intensity in each direction. The color scale displays the intensity. |
Equation (12) provides a reasonable estimate of the horizontal spot size (in the simulations here
2.9 µm) to be 2.6 µm as discussed earlier. Using equation (12)
, and data from Table 1
, we find the FWHM of the vertical spot size w = 2 µm, in excellent agreement with the simulations.
Fig. 3 shows the vertical spot size as a function of the longitudinal distance from the
lens. The calculated distance from the lens using the thin lens formula is 2.29 m
and corresponds to the vertical focal distance in the simulations. In these simulations,
the source is assumed to be Gaussian and centered on the center of the 8-ID straight
section.
![]() |
Figure 3 Simulated vertical focal spot profile in 8-ID-I as a function of the distance from the lens with a white-beam slit opening of 32 µm. |
Fig. 4 shows the horizontal spot size as a function of the longitudinal distance from the
lens. The horizontal focal plane is about 5 cm downstream from the vertical focal
position. Using the thin lens formula with the horizontal source position at the white-beam
slit location, we find the image distance from the lens should be 2.344 m, consistent
with the simulations.
![]() |
Figure 4 Simulated horizontal focal spot profile in 8-ID-I as a function of the distance from the lens with a white-beam slit opening of 32 µm. |
Fig. 5 shows the focal spot at the best horizontal focus in Fig. 4
. Because the horizontal and vertical source points are not in the same plane, it
is not possible to optimize both spot sizes simultaneously. The focal area, i.e. the product of the vertical and horizontal FWHM beam sizes, only varies by 6% between
the two planes defined in Figs. 2
and 5
. The distance between the horizontal and vertical best focus, here 5 cm, compares
with the vertical depth of focus of 3.7 cm computed in equation (15)
, but both distances are much larger than a typical sample thickness (∼3 mm) used
in our XPCS experiments, thus the astigmatic focus does not cause significant beam
waist changes over the illuminated length. An experimenter has the choice to explore
beam profile extremes shown in Figs. 2
and 5
by moving the sample along the beam direction.
![]() |
Figure 5 Simulated focal spot profile in 8-ID-I 2.34 m from the lens with a white-beam slit opening of 32 µm showing the smallest horizontal spot size. |
Simulations were also performed using a 1D, vertically focusing Be CRL. Fig. 6 shows the focal spot profile, with a horizontal coherence slit set to 20 µm, placed
88 cm after the lens. The vertical focal spot has also a FWHM of 2.0 µm, while the
horizontal profile is slightly broadened by Fraunhofer diffraction to a FWHM of 21 µm.
The transmitted partially coherent is 0.069% of the total emitted thus about 17% higher than for the 2D focusing case. The coherent transmitted through an aperture lx × ly at the lens position in Table 1
is 0.063% of the total emitted as computed with the XUS undulator simulation tool in XOP. The optical simulations are performed with wider horizontal slits than the XOP estimate, but they include geometrical and reflectivity losses so the transmitted
are similar to the XOP estimate.
![]() |
Figure 6 Simulated focal spot profile in 8-ID-I, using vertical focusing only with a wide-open white-beam slit opening. |
4. Experimental method
The experiment was performed on beamline 8-ID-I of the APS. Two 33 mm-period and 2.4 m-long
undulator A provide bright coherent X-rays on 8-ID. They add in phase at 7.35 and 11 keV.
Our test used only the upstream undulator A. Following the front-end, a small 0.275 mm-diameter
water-cooled pinhole located 26.0 m from the source reduces the incident power on
the beamline optics to a few Watts (Sandy et al., 1999, 2010
).
The white-beam slit is located downstream of the pinhole. Its opening can be estimated
from equation (2), with Rl = 66.9 m, Rs = 27 m, λ = 1.127 Å (11 keV), and FWHM = 0.125 mm. The FWHM used here is a typical slit opening
we use in front of the lens, and is significantly smaller than the vertical transverse
coherence length calculated from equation (1)
and shown in Table 1
. We roughly set the white-beam slit opening to 32 µm but it was challenging due to
mechanical issues with the slit stages. The tungsten edges are polished to 0.2 µm.
The white beam apertured by the slit is reflected by a water-cooled Si mirror with
a 2.5 mrad angle of incidence. The slit reduces the illumination of the mirror to
approximately 12% of its 11.0 cm length. A Ge (111) double-crystal monochromator diffracting
vertically was set to 10.6 keV (Narayanan et al., 2008
). Although we planned to work at 11 keV, the best focus ended up at 10.6 keV.
The focal length was adjusted by scanning the energy of the undulator and monochromator.
The focal spot size was estimated by measuring the speckle size from an aerogel using
a well known spatial autocorrelation technique (Sandy et al., 1999, 2010
). We note that this technique was recently extended to characterize the focal spot
size of CRL at the LCLS (Sikorski et al., 2015
). The technique is capable of measuring the focal spot size in 2D with single-shot
sensitivity, thus enabling X-ray laser shot-to-shot focus size monitoring. The focal
spot size was measured by the transmitted intensity with a PIN diode while scanning
a knife-edge using a cleaved GaAs wafer. These are well known to have atomically flat
edges convenient to probe a micrometre focal spot, or to be used as slit blades (Dufresne
et al., 2009
). The X-ray reported in this paper was calculated from the measured photocurrent from the diode.
5. Results
The horizontal beam profile in 8-ID-I upstream of the lens is shown in Fig. 7. It is measured with a 20 µm horizontal lens entrance slit placed 0.584 m upstream
of the lens (see Fig. 1
). It is much larger than the diffraction pattern of the white-beam slit because the
white-beam slit acts as a pinhole camera as shown in Fig. 1
. The measured FWHM of Fig. 7
is 0.757 mm, while using equation (8)
one finds a FWHM of 0.754 mm, in excellent agreement with the data. A Gaussian least-squares
fit is shown with a FWHM of 0.72 mm, and a small background of 1270 counts s−1. We note also that the measured beam profile is slightly asymmetric which we attribute
to the fact that the two blades of the white-beam slits do not reside in the same
plane. This effect has been shown to create an angle-dependent opening in coherence
slits (Libbert et al., 1997
).
![]() |
Figure 7 Horizontal beam profile in 8-ID-I just before the lens, with a white-beam slit opening of approximately 32 µm. The solid line is a Gaussian least-squares fit described in the text. |
We chose the number of lenses N such that it would focus 11 keV X-rays in the usual 8-ID-I sample location. To ensure
we achieved the best focus, we illuminated an aerogel sample with focused light and
measured the speckle contrast and speckle size from a well known technique, discussed
in Appendix B and by Sandy et al. (2010
).
Fig. 8 shows the speckle size as a function of the incident X-ray energy in the horizontal
and vertical direction. Since the speckle size is proportional to the width of the
Fraunhofer diffraction pattern of the illuminated sample area, the speckle size should
be maximum at the best focus energy. We note that the speckle size is larger in the
vertical direction most likely due to the smaller vertical source size. The data also
suggest a slight difference in focal length for the horizontal and vertical direction
due to the difference in peak energy of the speckle size. Since f increases with energy, the horizontal speckle size suggests the horizontal focus is upstream of the vertical one, in contrast with the
simulations.
![]() |
Figure 8 Measured horizontal and vertical speckle size from an aerogel pattern located in the focal plane. A pixel is 20 µm. |
It is possible that this effect is caused by slope errors on the water-cooled Ge(111)
monochromator. We have found that for vertical focusing we need to add more lenses
to focus at a given distance (Zhang et al., 2016). Zhang et al. vertically focused a 7.35 keV X-ray beam in 8-ID-I using the same geometry with Be
lenses with R = 0.2 mm using N = 10 instead of N = 7, the best choice from optical constants and equation (11)
(Zhang et al., 2016
). Calculations of this effect have been discussed recently (Antimonov et al., 2016
).
Fig. 9 shows the speckle contrast as a function of incident energy. The contrast is maximum
near 10.6 keV, but is not as sensitive to energy as the speckle size, and some small
scatter is present near the peak energy. The maximum contrast is approximately 29%,
which is close to the typical contrast on 8-ID-I in the unfocused condition.
![]() |
Figure 9 Measured speckle contrast from an aerogel pattern located in the focal plane. |
In this experiment, we scanned the incident energy and doing so moved the focus longitudinally along the beam propagation direction. Given the quadratic energy dependence of δ(E) ∝ 1/E2, a 100 eV shift reduction moved the focus upstream by Δz = 2fΔE/E ≃ 4 cm. It thus increased the illumination spot size by Δl/fΔz = 2ΔE/EΔl ≃ 2.3 µm. Thus we can also control the illuminated area by detuning the energy from the optimal focus. Changing the numerical aperture would also control the focal spot size.
We chose to probe the focus with a knife-edge scan at 10.6 keV. Fig. 10 shows the results of the vertical knife-edge scan with a step size of 0.5 µm, after
taking its spatial derivative. The vertical beam profile derived from the derivative
has a FWHM of approximately 3 µm, and compares well with the simulations (2 µm). The
vertical profile shows a long asymmetric tail with a possible diffraction fringe from
the 125 µm slit. The fringe could be due in part to the increased transverse coherence
in the vertical direction. Vertical fringes are visible in the simulation in Fig.
2
.
![]() |
Figure 10 Vertical beam profile in the focal plane. |
Fig. 11 shows the focal spot size with a Gaussian and Lorentzian non-linear least-squared
fit. The FWHM of the data is 3 µm. It compares well with estimates made earlier of
2.9 µm. The data overall lie between the two line shapes, indicating some tails with
larger background than a Gaussian line shape. We note that the horizontal profile
is significantly smaller than the FWHM of the demagnified source size 2.35σx(Re − Rl)/Rl = 22 µm. We achieved diffraction-limited focusing in the horizontal as well as in
the vertical direction. This is in good qualitative agreement with the simulations
performed.
![]() |
Figure 11 Horizontal beam profile in the focal plane from the derivative of the knife-edge scan, with a Gaussian and Lorentzian fit. |
The results were recently reproduced simultaneously on two beamlines 8-ID-E and 8-ID-I
at the APS at 7.35 keV. The experimental conditions are shown in Table 2. For this experiment, both our inline undulators were closed to produce optimal at 7.35 keV. From equation (1)
, the vertical transverse coherence length at this energy is 318 µm in 8-ID-I, but
we typically use 150 µm aperture before the lens when we focus vertically, thus using
equation (2)
with ly = 150 µm, we set the white-beam slit to 40 µm horizontally, optimal for the 8-ID-I
lens distance. A Si(220) crystal bisected the beam diffracted by the white-beam slit
diffracting half of the beam in 8-ID-E while the other half continued to 8-ID-I and
reflected from the horizontally deflecting Ge(111) double-crystal monochromator. We
recently reported how we changed the 8-ID-I monochromator from vertical to horizontal
deflection (Kearney et al., 2018
). The monochromator chamber was designed to accommodate either scattering direction
(Narayanan et al., 2008
). The speckle contrast at high angles in 8-ID-E was measured from a single crystal
of Fe3Al at its antiphase domain peak with a wavevector of 1.89 Å−1 (Brauer et al., 1995
). In 8-ID-E, a PI LCX:1300 CCD camera with 20 µm pixels was placed 1.1 m from the
focal spot. Because the data in WA-XPCS have a diffuse peak with often arbitrary shape,
the data were smoothed with a digital filtering technique developed earlier (Fluerasu
et al., 2005
). In this test, the 8-ID-I camera is a Medipix 3 Lambda 750k PAD from XSpectrum with
55 µm pixels, placed 3.93 m downstream of the aerogel sample discussed earlier. The
image distances i are for the horizontal and vertical direction, respectively. It uses the thin lens
formula with the source at the white-beam slit position in the horizontal direction
as stated earlier in Section 3
. The calculated focal spot size w is from equation (12)
. We found that we needed to reduce the horizontal beam acceptance to 100 µm in 8-ID-I
to produce the best focus. It is not clear why at this time. The results from the
tests are shown in Table 2
. The focal spot sizes compare well with the simple estimates provided in equation
(12)
, particularly after correcting for the broadening from astigmatism using equation
(14)
. It is not clear why the measured focal vertical spot in 8-ID-E differs from equation
(14)
. We succeeded in focusing in 2D with round parabolic lenses on two beamlines, delivering
good partially coherent and speckle contrast for XPCS experiments. This optical configuration was used for
the remainder of 2019 at 7.35 keV for 25% of the beam time on 8-ID, with a partially
coherent on the sample in 8-ID-E of 1.0 ± 0.5 × 1010 photons s−1, with the observed variation caused by different upstream alignment conditions.
|
More recently we also tested the same optics in 8-ID-E with the same conditions as
Table 2 but with a wide-open horizontal white-beam slit (see Appendix C
). The condition results in a 2.8 µm vertical spot size consistent with Table 2
, but the horizontal spot size is broader than the calculated image of the source
or pinhole by 43 to 72%, respectively, which further adds evidence of a heat bump
also present on the water-cooled Si monochromator.
6. Discussion
Experimenters performing XPCS experiments typically define coherent et al., 2006). For samples that are radiation sensitive, one prefers to illuminate the sample
with a single transverse coherent mode to maximize the contrast (DeCaro et al., 2013
).
Furthermore, the speckle contrast is maximum when a detector oversamples the speckle
pattern, and starts to decline when the ratio of the speckle area to the pixel area
here called rs is less than unity (Dufresne et al., 2002; Falus et al., 2006
). In the visible-light photon correlation spectroscopy community, it is well known
that the signal-to-noise ratio of the time correlation function improves in fact and
peaks at about rs ≃ 0.1 for single speckle measurements (Schätzel, 1990
). This scheme can be employed for samples that are insensitive to radiation damage
(Dufresne et al., 2002
). For samples that are radiation sensitive, one finds it best to match the speckle
area to the pixel area, both to enhance the range of wavevector covered by a camera
and to maximize the contrast which is a parameter in the signal-to-noise ratio (Falus
et al., 2006
; Vodnala et al., 2018
).
Returning to our measurements performed near 11 keV, we measured a focused partially
coherent 10 photons s−1. This is a factor 30% higher than without lenses in a 20 µm × 20 µm area and with
a fully opened horizontal white-beam slit. Since 20 µm is a typical coherence slit
opening used at 7.35 keV, we should compare the measured in an area (11/7.35)2 = 2.2 times smaller since the coherence lengths shrink by the ratio of energies.
The partially coherent is thus about a factor 1.3 × 2.2 = 2.9 times higher than in unfocused conditions
optimized for 11 keV. As noted in Table 1, the vertical opening in front of the lens could have been increased also to match
the transverse coherence length in this direction (factor 1.8 possible). These tests
were also performed with a single undulator A, but two inline phased undulators are
available on the 8-ID straight section (factor 2.5 possible at 11 keV).
There is another valuable function of reducing the white-beam slit opening in conditions
where the optics cannot preserve the et al., 2016). We reduced the total power on the first Ge(111) crystal of the double-crystal monochromator
in 8-ID-I by a factor of seven with the smaller slit and were able to produce a diffraction-limited
spot in the horizontal direction, and a much improved vertical focus on 8-ID-I. We
note that these measurements were performed when the monochromator diffracted vertically
(Kearney et al., 2018
).
For samples that are not prone to radiation damage, 2D focusing may be an advantage to match the speckle size to the pixel size. The PI camera used in this work has a pixel size of 20 µm, thus we measured a speckle size of around 120−140 µm, 4 m from the sample. This is fairly well matched to a modern PAD with pixel size ranging from 50 to 200 µm. Modern PADs absorb X-rays far more efficiently in their thick high-Z sensor (0.5 mm) than deep depletion silicon CCDs do, thus focusing may be helpful also with a PAD to allow their use with moderate sample–detector distance in existing facilities at X-ray energies above 10 keV.
We did not explore thoroughly the reduction of parasitic scattering from slits, Be
lens and windows in this setup. A single 2D slit before the lens produced the SAXS
speckle patterns of the aerogel sample. We found this setup remarkably free from parasitic
scattering. In an ultra-small-angle scattering experiment, we have noted some background
from the larger incoming angular divergence, thus one uses guard slits to reduce the
long tails on the focus. Although, since 2015, 2D focusing has only been used at 7.35 keV,
one should be able to image the pinhole described earlier and placed upstream of the
white-beam slit to produce higher intensity on samples at 11 keV with some reduction
in coherence. In light of recent evidence presented in Appendix C, one may require additional horizontal focusing to compensate for the heat bump of
the Ge monochromator in 8-ID-I.
We note that this optical scheme could be helpful at other synchrotrons with horizontal
source sizes comparable with or larger than the APS. Its use may also be helpful at
high-brightness rings such as Petra III, NSLS-2, or the new multiple bend achromat
sources (Tavares et al., 2018) when focusing high-energy X-rays above 20 keV. A high-precision and stable slit
is needed for this application.
7. Conclusions
This paper demonstrated the use of a white-beam slit to spatially filter the horizontal coherence and focus the beam in two dimensions with refractive lenses, producing improvements in partially coherent
and higher focal plane intensities on samples. Our water-cooled optics also benefit from the power reduction on the monochromators. The scheme is in routine use at two 8-ID beamlines sharing a single in-line straight section where two simultaneous XPCS experiments can be performed.APPENDIX A
Horizontal beam profile at the lens with a small white-beam slit opening
If we assume that the irradiance from a horizontal infinitesimal portion of the source
at position and angular emission angle () is Gaussian in both spatial and angular coordinates, then the intensity generated
by this element is
When we close the white-beam slit to an opening Δ, we image the source with a pinhole camera. Ignoring diffraction effects, the intensity at position xl in the lens plane is an image of the source irradiance with
Replacing x, and in equation (16)
, we find that the beam profile in the plane of the lens is
and thus a Gaussian in coordinate xl depending on both RMS source size and divergence, with a RMS beam size given in equation
(8).
APPENDIX B
Speckle metrology
A typical pattern from an aerogel measured with the PI camera is shown in Fig. 12. The intensity is displayed with a color map from blue (low intensity) to red (highest
intensity).
![]() |
Figure 12 2D speckle pattern of the aerogel measured at 10.63 keV, with a PI camera with 20 µm pixels, 4 m from the sample. The color scale is displayed in analog-to-digital units for this 16-bit camera. |
A standard technique to estimate the speckle size computes the 2D spatial autocorrelation
function of the speckle pattern (Abernathy et al., 1998; Tsui et al., 1998
; Sandy et al., 1999
). To remove the well known contribution due to Poisson noise of the detector (Dufresne
et al., 1995
), we perform a time average of a cross-correlation function of two speckle patterns
followed in time by one exposure period. Here, 63 such cross-correlation functions
were averaged, and the overall impact on these measurements reduces the peak by 0.01.
The cross-correlation function data are normalized to unity at large spatial lag.
A typical spatial cross-correlation function is shown in Fig. 13. Cuts in both directions were fit to Gaussians. A horizontal cut of Fig. 13
is shown in Fig. 14
with its Gaussian fit. The contrast is the peak value of the autocorrelation function
and is slightly higher than the value obtained from the speckle size fit shown as
a legend. The resulting FWHM in both direction were plotted in Fig. 8
.
![]() |
Figure 13 2D spatial autocorrelation function of a speckle pattern measured at 10.63 keV. The horizontal and vertical scales are in units of pixels. |
![]() |
Figure 14 An horizontal slice of the 2D spatial autocorrelation function in Fig. 13. The solid line is a least-square fit to a Gaussian. The horizontal axis is in units of pixels. |
APPENDIX C
Beam profiles in 8-ID-E with a wide open horizontal white-beam slit
In July 2020, we performed a focusing test with the same lenses in 8-ID-E with a wide
open horizontal white-beam slit. The conditions were the same as Table 2. Fig. 15
shows two beam profiles probed with the knife-edge, the sharp focus is in the vertical,
while the broad one is in the horizontal. The fits are arctan fits, the FWHMs quoted
are from the derivative of the fits. The vertical beam FWHM derived from the fit is
2.8 µm. One would expect to either demagnify the horizontal source (20 µm FWHM) or
the pinhole (16.6 µm FWHM). We observe 28.6 µm FWHM horizontally. We suspect this
broadening of the focal spot is caused by the heat bump of the Si monochromator which
is not observed in the vertical. The was 4.35 × 1010 photons s−1 in this mode, while the following week it was 7.5 × 109 photons s−1 with the WB slit closed to 40 µm, a factor of 5.8 higher. The ratio of the pinhole
and the WB slit opening is 6.9, thus the is 18% lower than expected. This condition would provide very low contrast for XPCS,
i.e. over ten coherence mode horizontally. These measurements complement our initial observation
in 8-ID-I.
![]() |
Figure 15 Horizontal (squares) and vertical (triangles) knife-edge scans of the beam profile in 8-ID-E. The solid and dashed lines are least-squares fit discussed in the text. |
Acknowledgements
We wish to thank Michael Fisher for the design of the lens holder, and Ray Ziegler for technical support. We are grateful for helpful discussions with Zhang Jiang, Oliver Schmidt, and Deming Shu. This material is based upon work supported by Laboratory Directed Research and Development (LDRD) funding from Argonne National Laboratory, provided by the Director, Office of Science, of the US Department of Energy under Contract No. DE-AC02-06CH11357. This research was performed on beamline 8-ID-I of the Advanced Photon Source, a US Department of Energy (DOE) Office of Science User Facility operated for the DOE Office of Science by Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
Funding information
Funding for this research was provided by: US Department of Energy Office of Science User Facility (award No. DE-AC02- 06CH11357).
References
Abernathy, D. L., Grübel, G., Brauer, S., McNulty, I., Stephenson, G. B., Mochrie,
S. G. J., Sandy, A. R., Mulders, N. & Sutton, M. (1998). J. Synchrotron Rad. 5, 37–47. Web of Science CrossRef CAS IUCr Journals Google Scholar
Antimonov, M., Khounsary, A., Sandy, A., Narayanan, S. & Navrotski, G. (2016). Nucl. Instrum. Methods Phys. Res. A, 820, 164–171. CrossRef CAS Google Scholar
Brauer, S., Stephenson, G., Sutton, M., Brüning, R., Dufresne, E., Mochrie, S., Grübel,
G., Als-Nielsen, J. & Abernathy, D. (1995). Phys. Rev. Lett. 74, 2010–2013. CrossRef PubMed CAS Web of Science Google Scholar
Chsuhkin, Y. (2020). ID10 EH2 Beamline Description. Technical Report. European Synchrotron Radiation Facility, Grenoble, France. Google Scholar
Chubar, O., Fluerasu, A., Berman, L., Kaznatcheev, K. & Wiegart, L. (2013). J. Phys. Conf. Ser. 425, 162001. CrossRef Google Scholar
DeCaro, C., Karunaratne, V. N., Bera, S., Lurio, L. B., Sandy, A. R., Narayanan, S.,
Sutton, M., Winans, J., Duffin, K., Lehuta, J. & Karonis, N. (2013). J. Synchrotron Rad. 20, 332–338. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dierker, S. (1997). In Light Scattering and Photon Correlation Spectroscopy, Proceedings of a NATO Advanced
Research Workshop, edited by E. Pike. Dordrecht: Kluwer Academic. Google Scholar
Dufresne, E., Brüning, R., Sutton, M., Rodricks, B. & Stephenson, G. B. (1995). Nucl. Instrum. Methods Phys. Res. A, 364, 380–393. CrossRef CAS Web of Science Google Scholar
Dufresne, E. M., Dierker, S. B., Yin, Z. & Berman, L. (2009). J. Synchrotron Rad. 16, 358–367. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dufresne, E. M., Nurushev, T. S., Clarke, R. & Dierker, S. B. (2002). Phys. Rev. E, 65, 061507. CrossRef Google Scholar
Elleaume, P. (2002). Undulators, Wigglers and Their Applications, edited by H. Onuki & P. Elleaume, p. 79. London: Taylor and Francis. Google Scholar
Falus, P., Lurio, L. B. & Mochrie, S. G. J. (2006). J. Synchrotron Rad. 13, 253–259. Web of Science CrossRef CAS IUCr Journals Google Scholar
Fluerasu, A., Sutton, M. & Dufresne, E. M. (2005). Phys. Rev. Lett. 94, 055501. Web of Science CrossRef PubMed Google Scholar
Goodman, J. (1985). Statistical Optics, 1st ed. New York: John Wiley & Sons. Google Scholar
Kearney, S., Dufresne, E., Narayanan, S., Sandy, A. & Shu, D. (2018). Proceedings of the 10th Mechanical Engineering Design of Synchrotron Radiation Equipment
and Instrumentation (MEDSI'18), 25–29 June 2018, Paris, France, pp. 391–393. Geneva: JACoW Publishing. Google Scholar
Lengeler, B., Schroer, C. G., Benner, B., Gerhardus, A., Günzler, T. F., Kuhlmann,
M., Meyer, J. & Zimprich, C. (2002). J. Synchrotron Rad. 9, 119–124. Web of Science CrossRef CAS IUCr Journals Google Scholar
Libbert, J. L., Pitney, J. A. & Robinson, I. K. (1997). J. Synchrotron Rad. 4, 125–127. CrossRef CAS Web of Science IUCr Journals Google Scholar
Livet, F. & Sutton, M. (2012). C. R. Phys. 13, 227–236. Web of Science CrossRef CAS Google Scholar
Narayanan, S., Sandy, A., Shu, D., Sprung, M., Preissner, C. & Sullivan, J. (2008).
J. Synchrotron Rad. 15, 12–18. Web of Science CrossRef IUCr Journals Google Scholar
Sandy, A. R., Lurio, L. B., Mochrie, S. G. J., Malik, A., Stephenson, G. B., Pelletier,
J. F. & Sutton, M. (1999). J. Synchrotron Rad. 6, 1174–1184. Web of Science CrossRef IUCr Journals Google Scholar
Sandy, A. R., Narayanan, S., Sprung, M., Su, J.-D., Evans-Lutterodt, K., Isakovic,
A. F. & Stein, A. (2010). J. Synchrotron Rad. 17, 314–320. CrossRef CAS IUCr Journals Google Scholar
Sandy, A. R., Zhang, Q. & Lurio, L. B. (2018). Annu. Rev. Mater. Res. 48, 167–190. Web of Science CrossRef CAS Google Scholar
Schätzel, K. (1990). Quantum Opt. 2, 287–305. Google Scholar
Schroer, C. G. & Falkenberg, G. (2014). J. Synchrotron Rad. 21, 996–1005. Web of Science CrossRef IUCr Journals Google Scholar
Shi, X., Reininger, R., Sanchez del Rio, M. & Assoufid, L. (2014). J. Synchrotron Rad. 21, 669–678. Web of Science CrossRef IUCr Journals Google Scholar
Sikorski, M., Song, S., Schropp, A., Seiboth, F., Feng, Y., Alonso-Mori, R., Chollet,
M., Lemke, H. T., Sokaras, D., Weng, T.-C., Zhang, W., Robert, A. & Zhu, D. (2015).
J. Synchrotron Rad. 22, 599–605. Web of Science CrossRef CAS IUCr Journals Google Scholar
Singer, A. & Vartanyants, I. A. (2014). J. Synchrotron Rad. 21, 5–15. Web of Science CrossRef IUCr Journals Google Scholar
Sinha, S. K., Jiang, Z. & Lurio, L. B. (2014). Adv. Mater. 26, 7764–7785. Web of Science CrossRef CAS PubMed Google Scholar
Snigirev, A., Kohn, V., Snigireva, A. & Lengeler, B. (1996). Nature, 384, 49–51. CrossRef CAS Google Scholar
Sutton, M. (2008). C. R. Phys. 9, 657–667. Web of Science CrossRef CAS Google Scholar
Tavares, P. F., Al-Dmour, E., Andersson, Å., Cullinan, F., Jensen, B. N., Olsson,
D., Olsson, D. K., Sjöström, M., Tarawneh, H., Thorin, S. & Vorozhtsov, A. (2018).
J. Synchrotron Rad. 25, 1291–1316. Web of Science CrossRef CAS IUCr Journals Google Scholar
Tsui, O. K. C., Mochrie, S. G. J. & Berman, L. E. (1998). J. Synchrotron Rad. 5, 30–36. Web of Science CrossRef CAS IUCr Journals Google Scholar
Vodnala, P., Karunaratne, N., Lurio, L., Thurston, G. M., Vega, M., Gaillard, E.,
Narayanan, S., Sandy, A., Zhang, Q., Dufresne, E. M., Foffi, G., Grybos, P., Kmon,
P., Maj, P. & Szczygiel, R. (2018). Phys. Rev. E, 97, 020601. Web of Science CrossRef PubMed Google Scholar
Wiegart, L., Rakitin, M., Zhang, Y., Fluerasu, A. & Chubar, O. (2019). AIP Conf. Proc. 2054, 060079. Google Scholar
Winarski, R. P., Holt, M. V., Rose, V., Fuesz, P., Carbaugh, D., Benson, C., Shu,
D., Kline, D., Stephenson, G. B., McNulty, I. & Maser, J. (2012). J. Synchrotron Rad. 19, 1056–1060. Web of Science CrossRef CAS IUCr Journals Google Scholar
Yang, B., Lee, S., Morgan, J. & Shang, H. (2017). Proceedings of the 5th International Beam Instrumentation Conference (IBIC 2016), Barcelona, Spain, edited by I. Costa, U. Iriso, F. Pérez & V. R. Schaa, pp. 504–507.
JACoW. Google Scholar
Zhang, Q., Dufresne, E. M., Grybos, P., Kmon, P., Maj, P., Narayanan, S., Deptuch,
G. W., Szczygiel, R. & Sandy, A. (2016). J. Synchrotron Rad. 23, 679–684. Web of Science CrossRef CAS IUCr Journals Google Scholar
Zozulya, A. V., Bondarenko, S., Schavkan, A., Westermeier, F., Grübel, G. & Sprung,
M. (2012). Opt. Express, 20, 18967–18976. Web of Science CrossRef CAS PubMed Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.