Volume 30, Issue S19 pp. 163-164
ABSTRACTS
Free Access

In-vivo animal model histological analysis of TiMg composite material for dental implants

Amir Catic

Amir Catic

Department of Fixed Prosthodontics, School of Dental Medicine, University of Zagreb, Croatia

Search for more papers by this author
Asja Muhic

Asja Muhic

Private dental practice Muhic, Bosnia and Herzegovina

Search for more papers by this author
Hajrudin Besirovic

Hajrudin Besirovic

University of Sarajevo, Faculty of Veterinary Medicine, Bosnia and Herzegovina

Search for more papers by this author
Martin Balog

Martin Balog

Slovak Academy of Sciences, Institute of Materials and Machine Mechanics, Slovakia

Search for more papers by this author
Peter Krizik

Peter Krizik

Slovak Academy of Sciences, Institute of Materials and Machine Mechanics, Slovakia

Search for more papers by this author
Zdravko Schauperl

Zdravko Schauperl

University of Zagreb, Faculty of Engineering and Naval Architecture, Croatia

Search for more papers by this author
First published: 25 September 2019
Citations: 2

16012 POSTER DISPLAY BASIC RESEARCH

Background

One of the main issues concerning dental implant materials arises from their Young's modulus being considerably higher than that of bone, which can generate stress-shielding effect and periimplant bone atrophy during loading. By use of advanced powder metallurgy novel titanium-magnesium (Ti12Mg) composite has been designed and consolidated. Results of ISO-standard based tests for dental implants demonstrated superior mechanical properties, in-vitro tests showed adequate biocorrosion.

Aim/Hypothesis

The aim of the study was to produce common dimension implants and assess the in-vivo osseointegration potentials of Ti12Mg composite metal on animal model.

Material and Methods

Study design was presented to ethical committees of both UNIZG School of Dental Medicine and UNISA Faculty of Veterinary Medicine, and the approvals acquired. Consolidated Ti12Mg implant material was roll-pressed into a 3,5 mm diameter bar and machined into 12 implants of 11 mm length. Implant neck geometry was modeled to allow for screw-motion placement. Four sheep of various ages were chosen from natural pasture farm with HACCP certificate and kept 30 days in controlled conditions with identical pasture prior to surgery. At the day of surgery three implants were epicrestally placed using regular implant surgical protocol in right tibia of each sheep 2 cm apart. After 4, 8 and 12 weeks from each sheep one implant and the surrounding bone were removed by a 7 mm diameter trephine bur, the samples prepared and histologically analyzed. All surgeries were performed in general anesthesia. After completion of the investigation sheep were healthy and in normal function.

Results

Both micro-CT and histological analyses demonstrated formation of bone at the bone to implant contact. Time-related bone maturation was typical for dental implants. However, BIC at 12 weeks was more mature at Ti12Mg implants in comparison to the commercially available implant. Histomorphometric analysis showed average BIC values within the bone marrow at 4 weeks 52%, at 8 weeks 81% and at 12 weeks 96%. BIC values within the cortical bone were 59% at 4 weeks, 89% at 8 weeks and 98% at 12 weeks. No signs of gaseous enclosures were determined in the surrounding bone.

Conclusion and Clinical Implications

Proposed Ti12Mg composite, with Mg phase acting as beneficiary modulator for generating an osseoconductive surface via spontaneous dilution in body environment as well as bone formation stimulant, suggests this material answers crucial demands for dental implants. Information concerning similar studies is scarce, and implant material where porous bioactive bimetallic composite is obtained with similar properties, has not so far been proposed.

    The full text of this article hosted at iucr.org is unavailable due to technical difficulties.