

research papers
Monochromatic computed microtomography using laboratory and synchrotron sources and 1
for comprehensive analysis of structural changes in bonesaShubnikov Institute of Crystallography RAS, Moscow, Russian Federation, bInstitute of Microelectronics Technology and High Purity Materials RAS, Moscow, Russian
Federation, cInstitute for Information Transmission Problems (Kharkevich Institute) RAS, Moscow,
Russian Federation, dResearch Institute of Human Morphology, Moscow, Russian Federation, eNational Research Centre `Kurchatov Institute', Moscow, Russian Federation, fDepartment of Innovation and High Technology, Moscow Institute of Physics and Technology,
Moscow, Russian Federation, and gDepartment of Computer Science, Loughborough University, Loughborough, UK
*Correspondence e-mail: [email protected]
A combination of X-ray tomography at different wavelengths and
was applied in the study of two types of bone tissue changes: prolonged presence in microgravity conditions and age-related bone growth. The proximal tail vertebrae of geckos were selected for investigation because they do not bear the supporting load in locomotion, which allows them to be considered as an independent indicator of gravitational influence. For the vertebrae of geckos no significant differences were revealed in the elemental composition of the flight samples and the synchronous control samples. In addition, the gecko bone tissue samples from the jaw apparatus, spine and shoulder girdle were measured. The dynamics of structural changes in the bone tissue growth was studied using samples of a human fetal hand. The hands of human fetuses of 11–15 weeks were studied. Autonomous zones of calcium accumulation were found not only in individual fingers but in each of the investigated phalanges. The results obtained are discussed.1. Introduction
The structure of living tissues can undergo partial changes due to various diseases
or in the case of extreme loads. These changes often do not have any external physiological
or anatomic signs. An examination of the changes allows one to reveal the reasons
for their origin. The knowledge obtained is important for diagnosis. Bone tissues
are a promising indicative object for research. Results of such studies can also be
used in bone-tissue engineering. Degeneration of tissues in microgravity is a serious
obstacle for long-term human stays in space or for interplanetary flights. It has
been found that a stay under these conditions leads to bone demineralization (Postnov
et al., 2003; Swinerd, 2008
). Changes in the concentration of other heavier elements can also be expected. Other
tissues of organisms may also have mechanosensitivity and need gravity to maintain
normal metabolism. Thus, bone and muscle tissues are kinds of `signalling systems',
showing the earliest and most obvious response to the impact of microgravity.
Studies of vertebrates in microgravity have been conducted from the early 1990s (Besova
et al., 1993; Besova & Savel'ev, 1993
; Grinfeld et al., 1994
; Savel'ev et al., 1995
) to the present (Roberts et al., 2008
; Asadchikov et al., 2012
; Sun et al., 2013
). Amphibians, reptiles and mammals have been investigated. A thorough analysis of
the results allowed the following assumption. The degree of skeleton demineralization
of different animals in conditions of weightlessness at the same (or approximately
the same) flight duration depends on the morphological and behavioral adaptations
of the investigated animals to their environment. To corroborate the assumption, both
traditional histological analyses of samples and alternative techniques are used today.
During the past several decades synchrotron sources have been used to determine the
structure and element composition of bone tissues [see, for example, Nuzzo et al. (2002
), Nikitin et al. (2007
, 2008
), Kharlamova et al. (2008
), Zanette et al. (2012
) and Deegan et al. (2015
)]. Computed tomography affords the restoration of a spatial distribution of the of the probing radiation. Here, the is a sum of coefficients for each individual element of the composition per unit
volume. For each element, the dependence of the on probing energy is unique and it is not linear. Hence, by changing the probing
energy and by analyzing the obtained results, it is possible to estimate the elemental
composition of each unit volume.
Following the reported detection of heavy element traces in the caudal vertebrae of
the thick-toed gecko (Asadchikov et al., 2012), we present the results of a comparative study of gecko bone tissues from different
areas of its body. Gecko bone tissues from several sources, including the jaw apparatus,
the spine and the bones of the shoulder girdle, are examined by computed tomography
for the first time. Samples from the flight (F) group and from the delayed synchronous
(S) control group were studied. First measurements were performed. Then X-ray tomographic experiments were carried out
at different energies to estimate the elemental composition distribution. The results
obtained are presented. Successful comparative studies of small gecko bones showed
that the technique can be applied to objects with smaller absorption. This conclusion
was confirmed by several experiments. Hands of human fetuses (11–15 weeks) were studied.
In each of the samples the tissues differ simultaneously in the amount of X-ray attenuation
in the range from water to bone elements. Using X-ray scanning at different wavelengths
allows an estimation of the distribution of major elements in the developing hand,
irrespective of the amount of attenuation of each component.
The sections are organized as follows. §2 details the samples, the setups used and the reconstruction technique. The results
obtained are discussed in §3
and the conclusion is given in §4
.
2. Experimental
2.1. Samples: geckos
We used bone tissues from Turner's thick-toed gecko (Chondrodactylus turneri, Gray, 1864); its most popular synonym is Pachydactylus turneri. We chose and investigated these reptiles as a model object for studying amniotes
on the FOTON-M unmanned spacecraft numbers 2 (M2) (16 days flight in 2005) and 3 (M3) (12 days flight in 2007
). Altogether 15 animals were used in each experiment: five each in the F group, the
basal control group and the S group. Group M2-F spent 16 days in orbit under the following
conditions: they were put in a container of 1.8 l volume, kept at an average temperature
of 288–290 K, with 40–45% air moisture and at a 2 mGy radiation level. Thirty-two
hours after the spacecraft landing the samples were transported to the laboratory,
where they were subjected to euthanasia by injection of Nembutal into the peritoneal
cavity. The basal control group was treated in the same way on the launch day. Prior
to that all animals had been kept in normal conditions in a terrarium with access
to water and food under a comfortable temperature of 298–306 K. Group M2-S was kept
in the laboratory under the same conditions as the M2-F group and was euthanized 48 h
later than the flight group. Each group consisted of one male and four female specimens.
For the M3-F group most of the experimental conditions were almost the same as for
M2-F. The first difference is that there were no male specimens in the groups: all
five animals in each of the three groups were females. The other difference is that
the average temperature maintained in the container was 293–295 K. This corresponds
to an active state for the geckos rather than to winter hibernation in the first expedition.
Finally, unlike the M2 expedition, the animals had access to water. After the satellite
landed, the animals were transported to the laboratory 13.5 h later.
2.2. Samples: human fetal hand
In a human limb the ossified bone elements are formed on the basis of replacement
of the cartilage. This fact does not allow the chondral period to be considered as
an appropriate period for evaluating the formation of dense bone matrix. That is why
preliminary histological studies were made. The results of these studies showed that
significant osteogenesis and the formation of zones of primary ossification, reaching
a size suitable for the local , 2005
). Up to now the localization of primary calcification foci of the hand skeleton anlage
is unknown. There is still no answer to the fundamental question of the existence
of many primary calcium deposition zones or one primary area. It has been suggested
that there are autonomous centers of ossification for each of the fingers, metacarpus
and carpus. For this reason, the aim of our work was to identify the spatial distribution
of the primary deposition foci of calcium and the associated elements in the human
hand. A preliminary histological evaluation allowed us to choose skeleton samples
from the right hand of human fetuses of 11–15 weeks of development. At these stages
of development, it is possible to determine the main phases of primary calcium depositions
in the fetal cartilage tissue, zones of cartilage resorption and secondary ossification.
Material on human development had been collected from 1978 to 1985 in the territory
of the USSR in accordance with the rules of the Health Ministry and stored in a special
collection of the depository at the Research Institute of Human Morphology.
2.3. Apparatus
Computed tomography systems consist of three main parts, namely a physical measuring
technique, which yields integral values of a required local variable along certain
paths, control and acquisition software, and a mathematical reconstruction algorithm,
which calculates the local value from the collected raw data. The local value is a
Z-dependence of linear attenuation, the measurements were carried out with a parallel
scanning scheme at different energies of 5.4, 8 and 10 keV. An advanced tomography
system based on a diffractometer constructed at the IC RAS (Senin et al., 2009) was used for 5.4 and 8 keV measurements to extract the contrast from sets of different
elements. Senin et al. (2009
) gave a detailed description of the experimental arrangement for laboratory tomography
measurements. The setup is illustrated schematically in Fig. 1
. An X-ray diffractometer is the basis of the setup.
![]() |
Figure 1 Scheme of the laboratory setup: (1) X-ray source (tube), (2) monochromator, (3) sample and (4) CCD detector. |
A conventional X-ray tube with Mo, Cu and Cr anodes was used as a radiation source.
X-ray radiation was monochromized by et al., 2013). A double-crystal Ge monochromator was placed to cut the 10 keV energy line. The
sample-to-CCD-detector distances were about 2.5–5 cm and the spatial resolution was
10 × 10 µm. The whole CT scan then had an angular step of 1° over a 360° angle. was carried out on an X-ray multifunctional SmartLab diffractometer with an Mo rotation
anode (Shared Research Center at IC RAS). Using a focusing diffraction mirror and
a Ge(220) monochromator allowed collimation and monochromatization of the probing
radiation in the measurements at 17.4 keV energy (Mo Kα). Fluorescence spectra were registered by the energy-dispersive X-Pips detector (resolution
120 eV). To collect integral fluorescence spectra the beam used was wide enough to
cover the sample entirely. The mapping of element distribution was made using a 0.25
× 0.5 mm beam.
2.4. Tomography reconstruction
For image reconstruction from tomographic projections we used a regularized algebraic
reconstruction technique (RegART) (Chukalina et al., 2007). It searches for an answer by solving a system of algebraic equations. ART is an
iterative algorithm which solves the system. Classic ART uses Kaczmarz's method (Kaczmarz,
1937
) for this. Briefly, it consists of by-turn projection of current image estimations
on hyperplanes defined by each equation of the system. The procedure is repeated again
if the reconstruction quality is not satisfactory. The behavior of this iterative
process heavily depends on the order of the used projections (Guan & Gordon, 1996
). We used the random access to projection algorithm to reduce the number of iterations
at a good quality of reconstruction (van Dijke, 1992
). Also the nVidia CUDA technology was used for boosting the algorithm (Buzmakov et al., 2011
).
3. Results and discussion
3.1. Gecko study
The X-ray tomography technique was used to measure gecko bone tissue samples from different locations: jaw, spine and bones of the shoulder girdle.
However, the and Fig. 2
. Table 1
presents the values of the linear absorption coefficients for representative elements
of the samples. The lists of the elements are chosen from X-ray fluorescent spectra
of vertebrae samples from the geckos (Fig. 3
). The number after the capital letters (S or F) corresponds to the number of the
sample in the group.
|
![]() |
Figure 2 Ca and Zn absorption edges. |
![]() |
Figure 3 X-ray fluorescence spectra of vertebrae from geckos (M2-S3 and M2-F3). |
Fig. 2 displays the Ca and the Zn absorption edges. The data files for graphs are taken
from https://skuld.bmsc.washington.edu/scatter/AS_periodic.html. It is easy to see that at an energy of 5.4 keV calcium absorption exceeds that of
zinc by one and a half times. At 10 keV the picture is completely opposite. The Zn
absorption is four times larger than the absorption by Ca. That is, if our sample
contained only calcium and zinc, we could estimate unambiguously the contents of each,
analyzing the results at 5 and 10 keV.
But, the samples analyzed have a more complicated composition. Therefore, we united
elements in groups, according to Fig. 4, to analyze their space distribution in the reconstructed images like those in Fig.
5
. If we consider the spectrum (Fig. 4
) from left to right, the first group of elements provides the greatest contribution
to the tomographic projection contrast at 5.4 keV energy (Figs. 5
a and 5c), the second one at 8 keV energy (Fig. 6
a) and the third one at 10 keV energy (Figs. 5b and 5d). Two spectra (M2-S3 and M2-F3) are presented in Fig. 3
.
![]() |
Figure 4 Fluorescence spectrum: divided into three zones according to the deposits in the process of absorption. |
![]() |
Figure 5 X-ray tomography reconstruction of gecko vertebra M2-S4 at 5.4 keV (a), (c) and at 10 keV (b), (d): magnified cross sections (a), (b) and volume images (c), (d). |
![]() |
Figure 6 (a) X-ray tomography reconstruction of gecko jaws at 8 keV and (b) the result of a reconstruction of a gecko tooth using Bragg magnifiers. |
The beam was wide enough to cover a sample entirely. Samples were placed on polished
silicon and sapphire plates with a known chemical composition. These experimental
conditions (angle of incidence is 0.25° and 0.1 × 10 mm slits are placed in front
of the sample) allowed the minimization of the contribution from the substrates to
a registered signal. The PyMCA program with GNU General Public License version 2.0 (GPLv2) was used for data analysis (Figs. 3 and 4
). Experiments were carried out in air, which gave rise to the peak of argon. The
presence of an Ni component is due to the design of the detector.
A comparison of the spectra for the F and the S series for both experiments on FOTON-M (M2 and M3) does not reveal strong bone-tissue demineralization. This could be due to the fact that the geckos were attached to the container surfaces during most of the flight. Minor differences are caused by two reasons. The fluorescence source distributions inside the vertebrae are not identical owing to the presence of individual features of the objects. The non-identical shape of the vertebrae causes different lengths for the optical paths of fluorescent radiation and hence a difference in the attenuation degree.
Fig. 5 presents the X-ray tomography reconstruction of the vertebra of a gecko (sample M2-S4)
at two different energies. Unlike the Table 1
, the voxel values in the figures are given in mm−1. Several homogeneous regions of interest (high-absorbing and low-absorbing regions)
on the reconstructed images were analyzed to calculate the relative errors (Dawood
et al., 2012
) for each energy. The results show that the errors do not exceed 10% in the region
of interest reviewed. Because the differences in the absorption contrast in full volume
images are hard to analyze, magnified cross sections are also presented in Fig. 5
. Comparison of the two cross sections showed that fluctuations in the distribution
of the main components in bone tissues are clearly observed at 5.4 keV. At high energy
this is enough information to describe the position and the size parameters of the
inclusions. However, to describe the precise composition of each individual inclusion,
the information is still not sufficient.
In Fig. 6(a) a reconstruction of the jaws of two geckos is presented. The measurements were made
at 8 keV.
To increase the spatial resolution we used a pair of crossed asymmetric cut single
crystals (Bragg magnifiers). Each crystal magnifies only in one direction; therefore,
a pair is used. Crystals were cut with the asymmetry coefficient 15 for 8 keV. Both
crystals were set to the maximum of the rocking curve, as any detuning from the peak
position primarily influences the spatial resolution. The scheme of this setup is
similar to that in Fig. 1, but asymmetric cut crystals were used instead of the monochromator. When calculating
the value of the we used the normalization on the X-ray beam measured after passing through the two
crystals in the absence of the studied sample according to the Beer–Lambert–Bouguer
law. The tooth of the same gecko jaw was chosen as a test object. In Fig. 6
(b) a reconstructed image of its structure with ∼1 µm voxel size is displayed. The image
is computer sectioned to show its inner structure.
Analysis of the measurement results of bone tissues from different parts of the gecko body did not reveal any great differences in the composition of the basic components of the bone tissue from different sources. Note that the artifacts in the reconstructed images have two sources. The first are artifacts of the reconstruction method. The second are related to the structure of the polypropylene holder which is attached to the samples.
3.2. Human fetal hand study
Samples of bones from human fetus hands were studied on the laboratory X-ray microtomography
setup and on a multifunctional diffractometer with a rotating anode and fluorescence
setup at the Shubnikov Institute of Crystallography RAS, and on the synchrotron station
`RT-MT' at the Kurchatov Synchrotron Center at the energies 8, 17.5 and 20 keV (corresponding
to the wavelengths 1.54, 0.71 and 0.5 Å). One of the samples was also studied using
an X-ray microtomograph Xradia VersaXRM-500 (https://www.xradia.com) at an accelerating voltage of 60 keV and a spatial resolution of ∼2 µm. In this
case, a polychromatic spectrum of radiation does not allow the acquisition of a true
value of the μ, although it does provide object reconstruction details of high quality. Typical
results of the reconstruction are shown in Fig. 7. Fig. 8
presents the results of a reconstruction of one of the objects (13 week sample) at
different wavelengths. This figure illustrates the significant changes in the absorbing
contrast caused by changing the wavelength of the probing radiation. In Fig. 9
the section of one of the samples and the ratio of its absorption at different wavelengths
are shown. We see (Fig. 9
b) that a change in wavelength in different parts of bone absorption varies non proportionally.
This fact, probably, indicates that high absorption elements (of higher atomic numbers)
are primarily concentrated in dense areas of the bone tissue.
![]() |
Figure 7 (a)–(c) Results of a reconstruction of human fetus hands (11–15 weeks). The wavelength of X-ray radiation is λ = 0.5 Å. (d) Reconstruction obtained on the X-ray microtomograph Xradia VersaXRM-500. |
![]() |
Figure 8 Reconstruction projections of a human fetus hand: 13 week sample using different wavelengths of X-ray radiation. (a) λ = 1.54 Å, (b) λ = 0.71 Å, (c) λ = 0.5 Å. The dotted line square encloses the fluorescent mapping region of interest discussed in the text. |
![]() |
Figure 9 (a) One of the tomographic sections of a sample of fetal hand bone and (b) the absorption ratio at different wavelengths. |
The composition of the samples includes elements in a wide range (Fig. 10a). Note that significant differences in the of some elements can be explained by individual variability of the samples. The element
distribution inside the samples was studied by mapping. A comparison of the Ca (as the matrix element) and the Zn distribution [Figs.
11
(a) and 11(b), correspondingly] shows that their localizations are different. For comparison with
the tomography data, the fluorescence mapping region is shown on Fig. 8
enclosed by the dotted line square. The measurement time is 5 min at each point.
intensity is presented in counts per second.
![]() |
Figure 10 (a) Fluorescence spectra from the 11 and 13 week samples. (b) Comparison of of the elements in the 11 and 13 week samples. |
![]() |
Figure 11 Mapping of (a) Ca and (b) Zn distributions in the 13 week sample. |
We can state that the greater part of the heavy element content is concentrated inside the densest part of the samples.
4. Conclusion
In this paper, we demonstrate the applicability of the combination of X-ray tomography at different wavelengths and
for the identification of differences in bone tissue. It was shown for the first time that gecko bone tissues from a variety of sources, including the jaw apparatus, spine and bones of the shoulder girdle, have no significant differences in their composition in spite of strong differences in the structure. Studies have shown that the peripheral parts of the samples contained no elements with atomic numbers greater than Ca or their concentration is smaller than the sensitivity of the tomographic technique. This is consistent with our earlier data obtained by For the vertebrae of geckos no significant differences were revealed in the elemental composition of flight (F) samples and synchronous (S) samples within each FOTON-M experiment (M2 and M3). Hands of human fetuses (11–15 weeks) were also studied. The differentiation of both bones of the hand and the phalanges of individual fingers occurs between the 11th and 15th weeks. At this period, the alternation of loose sections consisting of mesenchymal cells with anlages of cartilage and later the bone occurs. Our analysis of the dynamics of human hand development from 11 to 15 weeks of ontogenesis showed that outside the zones of extracellular matrix (Ca, P) formation a previously unknown morphological process occurs which predicts the direction of osteoblast differentiation. Autonomous zones of calcium accumulation were found not only in individual fingers but in each of the investigated phalanges. These data were confirmed by local analysis.Footnotes
1This article will form part of a virtual special issue of the journal, presenting some highlights of the 12th Biennial Conference on High-Resolution X-ray Diffraction and Imaging (XTOP2014).
Acknowledgements
This study was supported by the grants of the RFBR 13-02-00552, 13-07-00970, 13-07-12179 and by the Russian Ministry of Education and Science (agreement No. 14.616.21.0005). The investigations were partially performed using the equipment of the Shared Research Center of the Shubnikov Institute of Crystallography RAS and were supported by the Russian Ministry of Education and Science (project RFMEFI62114X0005), and the Mixed-Use Center of the Kurchatov Center of Synchrotron Radiation and Nanotechnologies (state contract No. 16.552.11.7003).
References
Asadchikov, V. E., Senin, R. A., Blagov, A. E., Buzmakov, A. V., Gulimova, V. I.,
Zolotov, D. A., Orekhov, A. S., Osadchaya, A. S., Podurets, K. M., Savel'ev, S. V.,
Seregin, A. Y., Tereshchenko, E. Y., Chukalina, M. V. & Kovalchuk, M. V. (2012). Crystallogr. Rep. 57, 700–707. CrossRef CAS Google Scholar
Besova, N. V. & Savel'ev, S. V. (1993). Bull. Exp. Biol. Med. 116, 87. Google Scholar
Besova, N. V., Savel'ev, S. V. & Chernikov, V. P. (1993). Bull. Exp. Biol. Med. 116, 90. Google Scholar
Buzmakov, A., Nikolaev, D., Chukalina, M. & Schaefer, G. (2011). Proceedings of the 33rd Annual International Conference of the IEEE EMBS, 30 August–3 September 2011, Boston, MA, USA, pp. 6200–6203. Google Scholar
Chukalina, M., Nikolaev, D. P. & Simionovici, A. (2007). Proceedings of ECMS 2007, 4–6 June 2007, Prague, Czech Republic, edited by I. Zelinka, Z. Oplatkova & A. Orsoni,
pp. 309–312. Google Scholar
Dawood, M., Jiang, X. & Schäfers, K. (2012). Editors. Correction Techniques in Emission Tomography, p. 147. Taylor and Francis Group. Google Scholar
Deegan, A. J., Cinque, G., Wehbe, K., Konduru, S. & Yang, Y. (2015). Anal. Bioanal. Chem. 407, 1097–1105. CrossRef CAS PubMed Google Scholar
Grinfeld, S., Foulquier, F., Mitashov, V., Bruchlinskaia, N. & Duprat, A. M. (1994).
Life Sciences Research in Space, Proceedings of the Fifth European Symposium, 1993, Arcachon, France, p. 181. Google Scholar
Guan, H. & Gordon, R. (1996). Phys. Med. Biol. 41, 1727–1743. CrossRef CAS PubMed Web of Science Google Scholar
Kaczmarz, S. (1937). Bull. Int. Acad. Pol. Sci. Lett. A, 35, 335–357. Google Scholar
Kharlamova, A., Barabanov, V. M., Proschina, A. E., Krivova, Y. S., Godovalova, O.
S., Savelieva, E. S., Okshtein, I. L., Souza, K. A., Almeida, E. A., Gulimova, V.
I., Nikitin, V. & Savel'ev, S. V. (2008). 29th Annual International Gravitational Physiology Meeting. Final Program and Abstracts, 22–27 June 2008, Angers, France, p. 164. Google Scholar
Nikitin, V. B., Gulimova, V. I., Ilyin, E. A., Asadchikov, V. E., Buzmakov, A. V.,
Okshtein, I. L. & Savel'ev, S. V. (2007). J. Gravit. Physiol. 14, 103–104. Google Scholar
Nikitin, V. B., Kharlamova, A. S., Godovalova, O. S., Proschina, A. E., Krivova, Y.
S., Savelieva, E. S., Gulimova, V. I., Barabanov, V. M., Ilyin, E. A. & Savel'ev,
S. V. (2008). 29th Annual International Gravitational Physiology Meeting. Final Program and Abstracts, 22–27 June 2008, Angers, France, p. 157. Google Scholar
Nuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J. & Boivin, G. (2002). Med. Phys. 29, 2672. CrossRef PubMed Google Scholar
Postnov, A. A., Vinogradov, A. V., Van Dyck, D., Savel'ev, S. V. & De Clerck, N. M.
(2003). Physiol. Meas. 24, 165–178. CrossRef PubMed CAS Google Scholar
Roberts, L., Almeida, E. A. C., Dvorochkin, N., Grigoryan, E. N., Savel'ev, S. V.,
Gulimova, V. I., Nikitin, V. B. & Wassersug, R. J. (2008). 29th Annual International Gravitational Physiology Meeting. Final Program and Abstracts, 22–27 June 2008, Angers, France, p. 154. Google Scholar
Savel'ev, S. V. (2002). The Stages of Human Brain Embryonic Development., p. 110. Moscow: VEDI. Google Scholar
Savel'ev, S. V. (2005). Atlas of Human Brain, p. 398. Moscow: VEDI. Google Scholar
Savel'ev, S. V., Barabanov, V. V., Besova, N. V., Gulimova, V. I., Makarov, A. N.
& Proshchina, A. E. (1995). Bull. Exp. Biol. Med. 119, 627–630. Google Scholar
Senin, R., Buzmakov, A. V., Konovko, A. V., Smirnov, I. S., Geranin, A. S. & Asadchikov,
V. E. (2009). J. Phys. Conf. Ser. 186, 12–35. CrossRef Google Scholar
Senin, R., Khlebnikov, A. S., Vyazovetskova, A. E., Blinov, I. A., Golubitskii, A.
O., Kazakov, I. V., Vorob'ev, A. A., Buzmakov, A. V., Asadchikov, V. E., Shishkov,
V. A., Mukhamedzhanov, E. Kh. & Kovalchuk, M. V. (2013). Crystallogr. Rep. 58, 517–522. CrossRef CAS Google Scholar
Sun, Y., Shuang, F., Chen, D. M. & Zhou, R. B. (2013). Osteoporos. Int. 24, 969–978. CrossRef CAS PubMed Google Scholar
Swinerd, G. (2008). How Spacecraft Fly: Spaceflight Without Formulae, p. 219. New York: Springer. Google Scholar
Van Dijke, M. C. (1992). PhD thesis, Rijksuniversiteit Utrecht, The Netherlands.
Google Scholar
Zanette, I., Bech, M., Rack, A., Le Duc, G., Tafforeau, P., David, C., Mohr, J., Pfeiffer,
F. & Weitkamp, T. (2012). Proc. Natl Acad. Sci. USA, 109, 10199–10204. Web of Science CrossRef CAS PubMed Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.