Volume 47, Issue 5 1 pp. 1303-1309
Innovative Surgical Techniques Around the World
Open Access

Novel Modality of Endoluminal Anastomotic Integrity Assessment with Fluoroangiography After Left-sided Colorectal Resections

Lidia Castagneto-Gissey

Lidia Castagneto-Gissey

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

Search for more papers by this author
Alessandra Iodice

Alessandra Iodice

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

Search for more papers by this author
Paolo Urciuoli

Paolo Urciuoli

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

Search for more papers by this author
Stefano Pontone

Stefano Pontone

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

Search for more papers by this author
Bruno Salvati

Bruno Salvati

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

Search for more papers by this author
Giovanni Casella

Corresponding Author

Giovanni Casella

Department of Surgical Sciences, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy

[email protected]Search for more papers by this author
First published: 24 January 2023
Citations: 1

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s00268-023-06915-8.

Abstract

Background

Several methods have been described for the intraoperative evaluation of colorectal anastomotic integrity. Technological evolution has allowed to progress from basic mechanical methods to the use of more sophisticated techniques. This study describes a novel endoluminal modality of colorectal anastomotic assessment through the use of a Disposable Rigid Scope Introducer (DRSI) also allowing for intraoperative endoluminal perfusion evaluation by indocyanine green (ICG) fluoroangiography in patients undergoing left-sided colorectal resection.

Methods

The DRSI consists of an endoluminal introducer device made up of an insertion tube and port connected to an insufflation bulb to manually insufflate the sigmoid and rectum and is compatible with any laparoscopic camera, also allowing for ICG fluoroangiography for perfusion purposes.

Results

The DRSI was successfully used to assess anastomotic integrity after left-sided colorectal resections performed in 16 consecutive patients. The DRSI allowed to visualize by fluoroangiography the quality of tissue perfusion at the anastomotic site in all cases, contributing to the decision of avoiding loop ileostomies in low rectal resections. In 2 cases, the DRSI showed the presence of significant anastomotic bleeding which was successfully controlled by laparoscopic suture placement. No adverse event resulted from the use of this device.

Conclusions

The DRSI combines direct endoluminal visualization of the anastomosis together with real-time evaluation of its blood flow. This device holds great potential for prompt intraoperative detection of anastomotic alterations, possibly reducing the risk of postoperative anastomotic bleeding or leaks related to mechanical construction/perfusion issues. Potential advantages of this device warrant larger cohort studies and prospective randomized trials.

Introduction

The current colorectal anastomotic leak rate persists to be relatively high, broadly ranging between 5 and 15% [1]. The pathogenesis of anastomotic colorectal leaks is by all means multifactorial [2, 3]. Although the surgeon may have no power over the modification of tumor and patient-specific variables, surgical technique of anastomotic construction—encompassing lack of tension, adequate vascularity and appropriate application of basic principles of anastomosis creation—is instead directly controllable by the surgeon [1].

Several methods have been described for intraoperative evaluation of the integrity of colorectal anastomoses following left-sided colorectal resections. Technological evolution has allowed to progress from basic mechanical methods to the use of more sophisticated techniques, including oxygen spectroscopy, narrow-band imaging, Doppler flowmetry and fluorescence angiography [3].

The ideal method of anastomotic assessment should allow for a direct visualization of the anastomosis both intra- and extra-luminally, additionally combining the possibility of examining tissue microperfusion at this level.

This study describes a novel endoluminal modality of colorectal anastomotic assessment through the use of a rigid scope introducer also allowing for intraoperative perfusion evaluation by indocyanine green (ICG) fluoroangiography in patients undergoing laparoscopic left-sided colorectal resection.

Materials and methods

The US Food and Drug Administration (FDA)- and European Committee (EC)-approved Disposable Rigid Scope Introducer (DRSI) (Novadaq Technologies Inc., Canada) device is currently commercially available. The DRSI consists of an endoluminal introducer made up of an insertion tube and insufflation port (Fig. 1). The insertion tube length of the DRSI is 255 mm. A seal is positioned within the connection area between the insertion tube and the handle; the seal provides an airtight device valve for insufflation.

Details are in the caption following the image

Disposable rigid scope introducer (DRSI) in insufflation (above) or irrigation setup (below). The DRSI can be connected to the insufflation bulb in order to adequately visualize the colorectal lumen or to a Luer-Lock syringe for irrigation/aspiration purposes

DRSI setting

The DRSI is intended to be used in the rectum and distal portions of the colon. It is designed for use with a standard laparoscope, 320 mm in length, 10 mm in diameter, 0 or 30° lens.

Once the DRSI/laparoscope complex is assembled, it is inserted just past the anal verge and the rectum is inflated through the insufflation bulb. Under direct visual guidance of the white light image, the device is advanced to the level of the anastomosis which is assessed for staple line disruption, bleeding and fluoroangiographic microperfusion (Video S1).

The ICG dose administered intravenously in the present study group was 0.3 mg/kg diluted in injectable sterile water. ICG injection was performed at two separate time points: at the moment of proximal colonic transection with direct visual inspection and after colorectal anastomotic construction with endoluminal assessment as evaluated through the DRSI device. An air-leak test was routinely performed while using the DRSI, by injecting saline solution in the abdominal field. (Additional technical details of the procedure are described in online Appendix.)

Study design

This is a pilot prospective cohort single-center study designed to evaluate anastomotic integrity through the use of the DRSI with concomitant ICG fluoroangiography. Between January and March 2022, a total of 16 patients affected by colorectal cancer or diverticular sigmoid stricture underwent laparoscopic left colectomy, anterior resection or sigmoidectomy at Sapienza University Hospital in Rome, Italy. Demographics, comorbidities and history of neoadjuvant radiochemotherapy were also recorded and are summarized in Table 1.

Table 1. Patient demographics and characteristics

Patient

Gender

Age (years)

BMI (kg/m2)

Comorbidities

Previous abdominal surgery

Diagnosis

Neoadjuvant CHT/RT therapy

1

M

71

25.2

No

No

Adenocarcinoma of the mid rectum (6 cm from a.v.)

Yes

2

M

43

24

No

No

Diverticulitis

No

3

M

76

25.3

Hypertension

inguinal hernia repair

Descending colon adenocarcinoma

No

4

M

65

29

Hypertension; COPD

No

Sigmoid adenocarcinoma

No

5

M

72

25.6

Hypertension

No

Adenocarcinoma of the mid rectum (8 cm from a.v.)

Yes

6

F

69

28

Hypothyroidism

Histerectomy

Sigmoid diverticular stricture

No

7

M

72

24

Hypertension

No

Sigmoid adenocarcinoma

No

8

M

81

23

Hypertension

Appendectomy

Adenocarcinoma of the high rectum (11 cm from a.v.)

Yes

9

M

77

25

Type 2 diabetes

Open prostatectomy

Adenocarcinoma of the low rectum (4 cm from a.v.)

Yes

10

F

81

22.4

No

No

Descending colon adenocarcinoma

No

11

F

76

21

No

No

Sigmoid diverticular stricture

No

12

M

59

24.7

No

No

Sigmoid adenocarcinoma

No

13

M

68

22.1

No

No

Adenocarcinoma of the high rectum (12 cm from a.v.)

Yes

14

F

70

24.9

Hypertension

Left ovariectomy

Sigmoid adenocarcinoma

No

15

M

78

23.8

Type 2 diabetes

No

Adenocarcinoma of the mid rectum (9 cm from a.v.)

Yes

16

M

73

30.2

Hypertension; ischemic cardiomyopathy

No

Sigmoid adenocarcinoma

No

  • BMI: body mass index; CHT/RT: chemoradiotherapy; M: male; F: female; a.v.: anal verge; COPD: chronic obstructive pulmonary disease

At the moment of proximal colonic transection and after colorectal anastomotic construction, perfusion was evaluated and judged as either ‘excellent’ (intensely bright and uniform distribution of ICG at the designated level of proximal colon transection); ‘good’ (uniform distribution of ICG at the designated level of proximal colon transection), ‘poor’ (uneven distribution of ICG at the designated level of proximal colon) or ‘absent’ (no ICG detected). In case of ‘poor’ or ‘absent’ ICG perfusion, a change in transection point was made based on the area of greater fluorescence. A decision of avoiding loop ileostomies in low anterior resections (i.e., anastomosis ≤ 5 cm from anal verge), regardless of preoperative neoadjuvant radiochemotherapy, was made when a ‘good’ or ‘excellent’ anastomotic perfusion was visualized endoluminally.

Considering a mean time between injection and fluorescence visualization of an estimated 30–60 s and the ICG half-life of 150–180 s, we assumed 180 s as an upper time limit to assess fluorescence.

To prove the applicability of the DRSI device, we performed laparoscopic left-sided colorectal resections in 16 consecutive patients for malignant or benign conditions with endoluminal anastomotic integrity assessment. All surgical procedures and DRSI usage were performed by the same two surgeons. Institutional Review Board and Ethical Committee approval was obtained. All participants provided written informed consent to participate in the study and before all surgical procedures.

The Template for Intervention Description and Replication (TIDieR) guideline was used in the present study for intervention reporting purposes.

Results

The DRSI was successfully used to assess anastomotic integrity after all left-sided colorectal resections performed in 16 consecutive patients (Table 1, 2).

Table 2. Perioperative data

Patient

Surgical procedure

Distance of anastomosis from anal verge (cm)

Endoluminal findings

ICG perfusion assessment

Intraoperative complications

Operative time (min)

Ileostomy

Clavien–Dindo

Postoperative hospital stay

30-day readmissions

1

LAR with TME

4

Patent, viable anastomosis

Excellent

No

210

No

6

No

2

Sigmoidectomy

15

Active anastomotic bleeding (12 o’clock)

Excellent

Anastomotic bleeding

198

No

5

No

3

Left hemicolectomy

12

Patent, viable anastomosis

Excellent

Perianastomotic serosal tear

260

No

5

No

4

Left hemicolectomy

10

Patent, viable anastomosis

Good

No

202

No

7

No

5

LAR with TME

4

Patent, viable anastomosis

Excellent

No

255

No

6

No

6

Sigmoidectomy

16

Patent, viable anastomosis

Good

No

178

No

6

No

7

Left hemicolectomy

11

Active anastomotic bleeding (1 o’clock)

Good

Anastomotic bleeding

191

No

5

No

8

AR with PME

8

Patent, viable anastomosis

Excellent

No

236

No

I

7

No

9

LAR with TME

2–3

Patent, viable anastomosis

Excellent

No

241

No

I

8

No

10

Left hemicolectomy

12

Patent, viable anastomosis

Excellent

No

211

No

5

No

11

Sigmoidectomy

16

Patent, viable anastomosis

Excellent

No

175

No

5

No

12

Left hemicolectomy

14

Patent, viable anastomosis

Good

No

188

No

6

No

13

AR with PME

7

Patent, viable anastomosis

Excellent

No

227

No

5

No

14

Left hemicolectomy

13

Patent, viable anastomosis

Excellent

No

236

No

I

7

No

15

LAR with TME

5

Patent, viable anastomosis

Good

No

240

No

6

No

16

Left hemicolectomy

12

Patent, viable anastomosis

Excellent

No

219

No

5

No

  • LAR: low anterior rectal resection; AR: anterior rectal resection; TME: total mesorectal excision; PME: partial mesorectal excision; ICG: indocyanine green

All procedures were performed laparoscopically. No conversions to open surgery, major intra-/postoperative complications or mortality were recorded. Minor postoperative complications (Clavien–Dindo grade I) included one case of ileus, one wound infection and one urinary tract infection. The DRSI allowed to visualize the anastomotic site in all cases with a ‘good’ or ‘excellent’ quality of tissue perfusion by ICG fluoroangiography (Fig. 2). In two cases, the DRSI showed the presence of significant anastomotic bleeding which was successfully controlled by laparoscopic suture placement (Fig. 2) under direct endoluminal control with DRSI. Operative time was increased by an estimated 15 min compared to the same surgical procedures performed without the use of the DRSI. Perioperative outcomes are shown in Table 2.

Details are in the caption following the image

Representative endoluminal images obtained with the use of the DRSI and laparoscope with fluorescence imaging system. a Normal appearance of colorectal anastomosis in white light mode; b ICG fluoroangiography in grayscale mode showing ‘excellent’ level of perfusion; c evidence of active anastomotic bleeding at 12 o'clock (arrow) in grayscale mode; d presence of large amount of blood clots just below the anastomosis; e active bleeding in overlay fluorescence mode

Discussion

Despite the substantial progress in technologies and refinement of surgical techniques, anastomotic leak rates still continue to complicate an elevated portion of colorectal procedures.

No definitive conclusions can yet be drawn from the current literature regarding the most effective modality of assessing anastomotic integrity [4]. A recent systematic review evaluating different approaches to colorectal anastomotic assessment could not find any superiority of one method over another, although advising to test anastomoses through basic air-leak tests to exclude mere mechanical failure [1].

An endoscopic view of the anastomosis allows for a more precise evaluation of tissue viability, as it has been proved that the mucosal layer has a lower tolerance to ischemia compared to the serosal lining [5]. The DRSI device allows for the concomitant use of a laparoscope and of an introducer combining the possibility of using a high-definition camera with a fluorescence imaging system for tissue perfusion assessment, at the same time conferring the possibility of adequate, albeit minimal, inflation and cleansing of the colorectal lumen for appropriate direct views of the colonic mucosa.

The DRSI demonstrated to have several advantages, including safety, limited costs, ease of use and high reproducibility. Additionally, it contributed to effectively indicate the presence of active anastomotic bleeding or adequate tissue perfusion in all cases. In our cohort of patients, the presence of good quality tissue perfusion visualized endoluminally via the DRSI drove the decision of avoiding loop ileostomies in selected cases. The limits we have experienced during the use of the DRSI include the need for an additional laparoscopic tower, the increase in the overall operative time, the possibility of exploring only up to 25 cm from the anal verge and the impossibility of performing operative maneuvers such as clip or suture placement when necessary (Table 3).

Table 3. Characteristics of the currently available intraoperative methods of anastomotic assessment with direct endoluminal visualization

Intraoperative endoscopy

Transanal platform

DRSI

Controlled low-pressure insufflation

Endoluminal ICG perfusion assessment

Visualization of high anastomoses

✓ (up to 25 cm)

Non-traumatic for anal sphincter due to small diameter of instrument (< 2 cm)

Requires additional laparoscopic tower

Requires additional CO2 insufflator

Allows operative maneuvers (eg. clip/suture placement)

Short learning curve

Low costs

Time saving

  • ICG: indocyanine green; DRSI: disposable rigid scope introducer

This device holds great potential for prompt intraoperative detection of anastomotic alterations, possibly reducing the risk of anastomotic leaks related to mechanical construction or perfusion issues. The potential advantages of this device warrant larger cohort studies and randomized trials.

Author contributions

All authors contributed to the study designed, manuscript writing, data collection and interpretation of the results. All authors provided critical feedback and helped shape the research, analysis and manuscript. All authors have approved the final version of the article.

Funding

Open access funding provided by Università degli Studi di Roma La Sapienza within the CRUI-CARE Agreement. No funds, grants or other support was received.

Declarations

Conflicts of interest

The authors declare that they have no conflict of interest.

Ethics approval

This study was performed in line with the principles of the Declaration of Helsinki. Institutional Review Board and Ethical Committee approval was obtained for this study.

Consent for publication

All participants provided written informed consent to participate in the study. Additional written informed consent was obtained before all surgical procedures.

  • 1 Video S1. Detailed use of the DRSI with a demonstration of four representative cases. The video can be found at: https://drive.google.com/file/d/1jGLHRatAJr20TBYULruc69sKwAI56K77/view?usp=sharing
  • Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
    • The full text of this article hosted at iucr.org is unavailable due to technical difficulties.