Emission of Volatile Organic Compounds from Furniture Coatings
T. Salthammer
Wilhelm-Klauditz-Institut (WKI), Frmmhofer-Institut für Holzforschung, Bienwder Weg 54 E, D-38108 Braunschweig, Germany. Phone (+49-531) 2155-350. Fax (+49-531) 351587
Search for more papers by this authorT. Salthammer
Wilhelm-Klauditz-Institut (WKI), Frmmhofer-Institut für Holzforschung, Bienwder Weg 54 E, D-38108 Braunschweig, Germany. Phone (+49-531) 2155-350. Fax (+49-531) 351587
Search for more papers by this authorAbstract
Abstract Emissions of volatile organic compounds (VOC) from different types of furniture coatings have been investigated by test chamber studies under dynamic conditions. A total of 150 VOCs could be identified in the chamber air. Compound groups occurring most often were aliphatic and aromatic aldehydes, ketones, aromatic hydrocarbons, glycols and esters. Special attention was paid to the detection of typical components of coating materials such as acrylic monomers, photoinitiators and other additives. The TVOC-values, measured after a preconditioning period of 20 days, ranged from 4 μg/m3 to 1288 μg/m3 with an arithmetic mean of 173.9 μg/m3 and a median 60.0 μg/m3. The highest chamber concentrations of individual components were found for some solvent residues such as n-butylacetate, butylgly-col, 1-butanol-3-methoxy-acetate and butyldiglycolacetate. The results have shown that furniture may contribute significantly to indoor air pollution. The calculated emission factors were comparable with data reported for other indoor materials.con
References
- Andersen, I., Lundquist, G.R. and Mølhave L. (1975) “Indoor air pollution due to chipboard used as a construction material”, Atmospheric Environment, 9, 1121–1127.
- De Bortoli, M., KnöUppel, H., Colombo, A. and Kefalopoulos, S. (1996) “ Attempting to characterize the sink effect in a small stainless steel test chamber”. In: B.A. Tichenor (ed.) Characterizing Sources of Indoor Air Pollution and Related Sink Effects, Philadelphia , American Society for Testing and Materials, pp. 307–320 (ASTM STP 1287).
- Brown, S.K., Sim, M.R., Abramson, M.J. and Gray, C.N. (1994) “Concentrations of volatile organic compounds in indoor air - a review”, Indoor Air, 4(2), 123–134.
- Commission of the European Communities (CEC) (1993) Determination of VOCs Emitted from Indoor Materials and Products, Brussels , COST Project 613, Report No. 13.
- Commission of the European Communities (CEC) (1994) Sampling Strategies for Volatile Organic Compounds (VOCs) in Indoor Air, Brussels , COST Project 613, Report No. 14.
- Daisey, J.M., Hodgson, A.T., Fisk, W.J., Mendell, M.J. and Brinke, J.T. (1994) “Volatile organic compounds in twelve Californian office buildings: classes, concentrations and sources”, Atmospheric Environment, 28, 3557–3562.
- Deutsche Forschungsgemeinschaft (DFG) (1995) MAK- und BAT-Werte-Liste. Weinheim, VCH Verlagsgesellschaft mbH.
- Dietliker, K.K (1991) “ Photoinitiators for free radical and cationic polymerization”. In: P.K.T. Oldring (ed.) Chemistry and Technology of UV & EB Formulation for Coatings, Inks and Paints, London , SITA Technology Ltd., Vol. 3.
- Ekberg, L.E. (1994) “Volatile organic compounds in office buildings”, Atmospheric Environment, 28, 3571–3575.
- Fellin, P. and Otson, R. (1994) “Assessment of the influence of climatic factors on concentration levels of volatile organic compounds (VOCs) in Canadian homes”, Atmospheric Environment, 28, 3581–3586.
- Fischer, M. und BöUhm, E. (1994) Erkennung und Bewertung von Schadstoffemissionen aus Möbellacken, Reihe Schadstoffe und Umwelt, Band 12, Berlin , Erich Schmidt Verlag.
- Girman, A., Hodgson, A.T., Newton, A.S. and Winkens, A.W. (1986) “Emissions of volatile organic compounds from adhesives with indoor applications”, Environment International, 12, 317–321.
- Graham, R.C. (1993) Data Analysis for the Chemical Sciences, New York , VCH Publishers Inc.
- Gustafsson, H. (1992) Building Materials Identified as Major Sources for Indoor Air Pollutants - a Critical Review of Case Studies, Stockholm , Swedish Council for Building Research, (Report No. D10:1992).
-
Hagemann, H.J. (1989) “ Photoinitiators and photoionization mechanisms of free-radical polymerisation processes”. In: N.S. Allen (ed.)
Photopolymerisation and Photoimaging Science and Technology, Crown House, Elsevier Ltd, pp.
1–53.
10.1007/978-94-009-1127-7_1 Google Scholar
- Jensen, B., Wolkoff, P., Wilkins, C.K. and Clausen, P.A. (1995a) “Characterization of linoleum. Part 1: measurement of volatile organic compounds by use of the field and laboratory emission cell, ‘FLEC’”, Indoor Air, 5(1), 38–43.
- Jensen, B., Wolkoff, P. and Wilkins, C.K. (1995b) “Characterization of linoleum. Part 2: Preliminary odor evaluation”, Indoor Air, 5(1), 44–49.
- Krause, C., Mailahn, W., Nagel, R., Schulz, C., Seifert B. and Ullrich, D. (1987) “ Occurrence of volatile organic compounds in the air of 500 homes in the Federal Republic of Germany”. In: B. Seifert, H. Esdorn, M. Fischer, H. Ruden and J. Wegner (eds). Proceedings of Indoor Air '87, Berlin , Institute of Water, Soil and Air Hygiene, Vol. 1, pp. 102–106.
- Little, J.C., Hodgson, A.T. and Gadgil, A.J (1994) “Modeling emissions of volatile organic compounds from new carpets”, Atmospheric Environment, 28, 227–234.
- Maroni, M., Seifert, B. and Lindvall, T. (1995) Indoor Air Quality - a Comprehensive Reference Book, Amsterdam , Elsevier.
- Mattinen, M.-L., Tuominen, J. and Saarela, K. (1995) “Analysis of TVOC and certain selected compounds from indoor air using GC/FID-RIM technique”, Indoor Air, 5(1), 56–61.
- McLafferty, F.W. and Turecek, F. (1993) Interpretation of Mass Spectra. Mill Valley , University Science Books.
- Miksch, R.R., Hollowell, C.D. and Schmidt. H.E. (1982) “Trace organic chemical contaminants in office spaces”, Environment International, 8, 129–137.
- Mølhave, L. (1995) “ Evaluation of VOC emissions from materials and products: solid flooring materials”. In: M. Maroni (ed.) Proceedings of Healthy Buildings '95, Milano , Vol. 1, 145–162.
- Otson, R., Fellin, P. and Tran Q. (1994) “VOCs in representative Canadian residences”, Atmopheric Environment, 28, 3563–3569.
- Ruth, J.H. (1986) “Odor thresholds and irritation levels of several chemical substances: a review”, Journal of the American Industrial Hygiene Association, 47, A/142-A/151.
- Saarela, K., Tirkkonen, T. and Tahinen, M. (1994) Preliminary Data Ease for Material Emissions, Helsinki , Nordic Committee on Building Regulations (NKB), Indoor Climate Committee (Report No.l994:04E).
- Salthammer, T. (1994) “Luftverunreinigende organische Sub-stanzen in Innenräumen”, Chemie in unserer Zeit, 28, 280–290.
- Salthammer T. (1996) “Emission of photoinitiator fragments from UV-cured furniture coatings”, Journal of Coatings Technology, 68, 41–47.
- Salthammer, T. and Marutzky, R. (1995a) “ Kammerverfahren zur Bestimmung der Emissionen organischer Substanzen aus Materialien”. In: E. Bagda (ed.) Emissionen aus Beschich-tungsstoffen und deren Einfluβ auf die Innenraumluft, Renningen, Expert-Verlag, pp. 75–94.
- Salthammer, T. and Marutzky, R. (1995b) “Emissionen organischer Verbindungen aus Möbeloberflächen”, Holz-Zentralblatt, Nr.144/95, 2405 and Nr. 6/96, 57–58.
- Salthammer, T., Schriever E. and Marutzky, R. (1993) “Emissions from wallcoverings: test procedures and preliminary results”, Toxicological and Environmental Chemistry, 40, 121–131.
- Salthammer, T., Fuhrmann, F, Kaufhold, S., Meyer, B. and Schwarz, A. (1995) “Effects of climatic parameters on formaldehyde concentrations in indoor air”, Indoor Air, 5(2), 120–128.
- Schriever, E. and Marutzky, R. (1990) “ VOC-emissions of coated parqueted floors”. In: D.S. Walkinshaw (ed.) Proceedings of Indoor Air '90, Toronto , Canada Mortgage and Housing Corporation, Vol. 3, pp. 551–556.
- Seifert, B., Mailahn, W., Schulz, C. and Ullrich, D. (1989) “Seasonal variation of concentrations of volatile organic compounds in selected German homes”, Environment International, 15, 397–408.
- Sheldon, L.S., Handy, R.W., Hartwell, T.D., Whitmore, R.W., Zelon, H.S. and Pellizzari, E.D. (1988a) Indoor Air Quality in Public Buildings: Vol. 1, Washington D.C. , Research Triangle Institute, EPA Project Summary No. 600/S6–88/009a.
- Sheldon, L.S., Zelon, H.S., Sickles, J., Eaton, C., Hartwell, T. and Wallace L. (1988b) Indoor Air Quality in Public Buildings: Vol.2. Washington D.C. , Research Triangle Institute (EPA Project Summary No. 600/S6–88/009b).
- Sollinger, S, Levsen, K. and Wiinsch G. (1993) “Indoor air pollution by organic emissions from textile floor coverings. Climate chamber studies under dynamic conditions”, Atmospheric Environment, 27B, 183–192.
- Sollinger, S., Levsen, K. and Wünsch G. (1994) “Indoor air pollution by organic emissions from textile floor coverings. Climate test chamber studies under static conditions”, Atmospheric Environment, 28, 183–192.
- Tähtinen, M., Saarela, K. and Tirkkonen, T. (1995) “ Results from material emission measurements at VTT”. In: M. Maroni (ed.) Proceedings of Healthy Buildings, Milano, Vol. 2, pp. 917–922.
- Tirkkonen, T., Mroueh, U.M. and Orko, I. (1995) Tenax as a Collection Medium for Volatile Organic Compounds - Literature survey, Helsinki , Nordic Committee on Building Regulations (NKB), Indoor Climate Committee (Report No.l995:06E).
- Wilkins, C.K., Wolkoff, P., Gyntelberg, E, Skov, P. and Valbjarn, O. (1993) “Characterization of office dust by VOCs and TVOC-release -identification of potential irritant VOCs by partial least squares analysis”, Indoor Air, 3(4), 283–290.
- Wolkoff, P. and Nielsen, P.A. (1993) Indoor Climate Labeling of Building Materials, Copenhagen , National Institute of Occupational Health, Danish Building Research Institute.
- Wolkoff P. and Wilkins C.K. (1994) “Indoor VOCs from household floor dust: comparison of headspace with de-sorbed VOCs; method for VOC release determination”, Indoor Air, 4(4), 248–254.
- Yocom, J.E. and McCarthy, S.M. (1991) Measuring Indoor Air Quality, Baffins Lane, John Wiley & Sons Ltd.