Artificial Organs 2008: A Year in Review
Paul S. Malchesky,
Paul S. Malchesky
Artificial Organs Editorial Office, Painesville, OH, USA
Search for more papers by this authorPaul S. Malchesky,
Paul S. Malchesky
Artificial Organs Editorial Office, Painesville, OH, USA
Search for more papers by this authorDr. Paul S. Malchesky, Artificial Organs Editorial Office, 10 West Erie Street, Suite 200, Painesville, OH 44077, USA. E-mail: [email protected]

REFERENCES
- 1 Johnson CA Jr, Snyder TA, Woolley JR, Wagner WR. Flow cytometric assays for quantifying activated ovine platelets. Artif Organs 2008; 32: 136–45.
- 2 Radovancevic R, Bracey AW, Radovancevic B, Elayda M, Gregoric ID, Frazier OH. Plasma exchange before surgery for left ventricular assist device implantation. Artif Organs 2008; 32: 427–32.
- 3 Biglino G, Whitehorne M, Pepper JR, Khir AW. Pressure and flow-volume distribution associated with intra-aortic balloon inflation: an in vitro study. Artif Organs 2008; 32: 19–27.
- 4 Choi H, Min BG, Won YS. Comparison of hemolytic properties of different shapes of occlusion of blood sac in occlusive-type pulsatile blood pump. Artif Organs 2008; 32: 160–6.
- 5 Kosaka R, Sankai Y, Yamane T, Tsutsui T. Resonant frequency control method for total artificial heart: in vitro study. Artif Organs 2008; 32: 157–60.
- 6 Noh MD, Antaki JF, Ricci M, et al. Magnetic design for the PediaFlow ventricular assist device. Artif Organs 2008; 32: 127–35.
- 7 Maruyama O, Yamaguchi K, Nishida M, et al. Hemolytic evaluation using polyurethane microcapsule suspensions in circulatory support devices: normalized index of hemolysis comparisons of commercial centrifugal blood pumps. Artif Organs 2008; 32: 146–56.
- 8 Fonseca J, Andrade A, Nicolosi DE, et al. A new technique to control brushless motor for blood pump application. Artif Organs 2008; 32: 355–9.
- 9 Felipini CL, De Andrade AJ, Lucchi JC, Da Fonseca JW, Nicolosi D. An electro-fluid-dynamic simulator for the cardiovascular system. Artif Organs 2008; 32: 349–54.
- 10 Legendre D, Antunes P, Bock E, Andrade A, Biscegli JF, Ortiz JP. Computational fluid dynamics investigation of a centrifugal blood pump. Artif Organs 2008; 32: 342–8.
- 11 Horikawa O, De Andrade AJ, Da Silva I, Bock EG. Magnetic suspension of the rotor of a ventricular assist device of mixed flow type. Artif Organs 2008; 32: 334–41.
- 12 Bock E, Ribeiro A, Silva M, et al. New centrifugal blood pump with dual impeller and double pivot bearing system: wear evaluation in bearing system, performance tests, and preliminary hemolysis tests. Artif Organs 2008; 32: 329–33.
- 13 Jahanmir S, Hunsberger AZ, Heshmat H, et al. Performance characterization of a rotary centrifugal left ventricular assist device with magnetic suspension. Artif Organs 2008; 32: 366–75.
- 14 Chua LP, Ong KS, Song G. Study of velocity and shear stress distributions in the impeller passages and the volute of a bio-centrifugal ventricular assist device. Artif Organs 2008; 32: 376–87.
- 15 Onorati F, Esposito A, Comi MC, et al. Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass. Artif Organs 2008; 32: 433–41.
- 16 Lee H, Taenaka Y. Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device. Artif Organs 2008; 32: 453–60.
- 17 Manning KB, Wivholm BD, Yang N, Fontaine AA, Deutsch S. Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design. Artif Organs 2008; 32: 442–52.
- 18 Legendre D, Fonseca J, Andrade A, et al. Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases. Artif Organs 2008; 32: 461–7.
- 19 Yamane T, Maruyama O, Nishida M, et al. Antithrombogenic properties of a monopivot magnetic suspension centrifugal pump for circulatory assist. Artif Organs 2008; 32: 484–9.
- 20 Herreros J, Berjano EJ, Sales-Nebot L, et al. A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system. Artif Organs 2008; 32: 490–4.
- 21 Doi T, Kamiya H, Watanabe G, Misaki T. A coronary active perfusion system for off-pump coronary artery bypass grafting in an experimental porcine model: the relationship between flow rate and myocardial function. Artif Organs 2008; 32: 525–30.
- 22 Hijikata W, Shinshi T, Asama J, et al. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head. Artif Organs 2008; 32: 531–40.
- 23 Pitsis AA, Visouli AN, Ninios V, et al. Elective bridging to recovery after repair: the surgical approach to ventricular reverse remodeling. Artif Organs 2008; 32: 730–5.
- 24 Arndt A, Nusser P, Graichen K, Muller J, Lampe B. Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient. Artif Organs 2008; 32: 761–71.
- 25 Hilton A, Tansley G. Magnetic drive system for a new centrifugal rotary blood pump. Artif Organs 2008; 32: 772–7.
- 26 Triep M, Brucker C, Kerkhoffs W, Schumacher O, Marseille O. Investigation of the washout effect in a magnetically driven axial blood pump. Artif Organs 2008; 32: 778–84.
- 27 Sakota D, Sakamoto R, Sobajima H, et al. Mechanical damage of red blood cells by rotary blood pumps: selective destruction of aged red blood cells and subhemolytic trauma. Artif Organs 2008; 32: 785–91.
- 28 Linneweber J, Dohmen PM, Kertzscher U, Affeld K, Konertz W. Local glycoprotein IIb/IIIa receptor inhibitor delivery from the pump surface attenuates platelet adhesion in continuous flow ventricular assist devices. Artif Organs 2008; 32: 792–9.
- 29 Timms D, Fraser J, Hayne M, Dunning J, McNeil K, Pearcy M. The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artif Organs 2008; 32: 816–9.
- 30 Sandner SE, Zimpfer D, Zrunek P, et al. Low molecular weight heparin as an alternative to unfractionated heparin in the immediate postoperative period after left ventricular assist device implantation. Artif Organs 2008; 32: 819–22.
- 31 Choi SW, Nam KW. Venous pressure regulation during pulsatile extracorporeal life support. Artif Organs 2008; 32: 822–7.
- 32 Bainbridge D, Jones DL, Guiraudon GM, Peters TM. Ultrasound image and augmented reality guidance for off-pump, closed, beating, intracardiac surgery. Artif Organs 2008; 32: 840–5.
- 33 Oc M, Ucar HI, Pinar A, et al. Heat shock protein70: a new marker for subsequent atrial fibrillation development? Artif Organs 2008; 32: 846–50.
- 34 Murkin JM. Applied neuromonitoring and improving central nervous system outcomes. Artif Organs 2008; 32: 851–5.
- 35 Borisov KV, Bockeria LA, Sinyov AF. Surgical treatment of hypertrophic obstructive cardiomyopathy in pediatric patients with severe hypertrophy. Artif Organs 2008; 32: 856–63.
- 36 Doyle MG, Vergniaud JB, Tavoularis S, Bourgault Y. Numerical simulations of blood flow in artificial and natural hearts with fluid-structure interaction. Artif Organs 2008; 32: 870–9.
- 37 Ordodi VL, Paunescu V, Ionac M, et al. Artificial device for extracorporeal blood oxygenation in rats. Artif Organs 2008; 32: 66–70.
- 38 Yasuda T, Saito T, Kihara T, Takatani S, Funakubo A. Development of a reflected optical fiber system for measuring oxygen saturation in an integrated artificial heart-lung system. Artif Organs 2008; 32: 229–34.
- 39 Simons AP, Ganushchak Y, Wortel P, et al. Laboratory performance testing of venous cannulae during inlet obstruction. Artif Organs 2008; 32: 566–71.
- 40 Cai J, Su Z, Shi Z, et al. Nitric oxide in conjunction with milrinone better stabilized pulmonary hemodynamics after fontan procedure. Artif Organs 2008; 32: 864–9.
- 41 Slaughter MS, Sobieski MA, Tatooles AJ, Pappas PS. Reducing emboli in cardiac surgery: does it make a difference? Artif Organs 2008; 32: 880–4.
- 42 Jungebluth P, Iglesias M, Go T, Sibila O, Macchiarini P. Optimal positive end-expiratory pressure during pumpless extracorporeal lung membrane support. Artif Organs 2008; 32: 885–90.
- 43 Al-Ruzzeh S, Epstein D, George S, et al. Economic evaluation of coronary artery bypass grafting surgery with and without cardiopulmonary bypass: cost-effectiveness and quality-adjusted life years in a randomized controlled trial. Artif Organs 2008; 32: 891–7.
- 44 Kim WG. Temperature control using a heat exchange of a cardioplegic system in cardiopulmonary bypass model for rats. Artif Organs 2008; 32: 993–8.
- 45 Slight RD. Oxygen delivery and hemoglobin concentration in cardiac surgery: when do we have enough? Artif Organs 2008; 32: 949–55.
- 46 Zhou C. Changes in atrial natriuretic peptide levels during cardiac bypass in the fetal goat. Artif Organs 2008; 32: 956–61.
- 47 Motta AB, Pereira LC, Da Cunha AR, Duda FP. The influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture. Artif Organs 2008; 32: 283–91.
- 48 Takamori ER, Cruz R, Goncalvez F, Zanetti RV, Zanetti A, Granjeiro JM. Effect of roughness of zirconia and titanium on fibroblast adhesion. Artif Organs 2008; 32: 305–9.
- 49 Gabriel SB, Nunes CA, Soares G de A. Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys. Artif Organs 2008; 32: 299–304.
- 50 De Medeiros WS, De Oliveira MV, Pereira LC, De Andrade MC. Bioactive porous titanium: an alternative to surgical implants. Artif Organs 2008; 32: 277–82.
- 51 Ilonen I, Koivusalo AM, Repo H, Hockerstedt K, Isoniemi H. Cytokine profiles in acute liver failure treated with albumin dialysis. Artif Organs 2008; 32: 52–60.
- 52 Yang WS, Tan HK, Lui HF, Chow PK, Choong HL, Wong KS. Albumin dialysis in critically ill patients: use versus omission of intradialytic heparin. Artif Organs 2008; 32: 411–6.
- 53 Patzer JF 2nd. Thermodynamic considerations in solid adsorption of bound solutes for patient support in liver failure. Artif Organs 2008; 32: 499–508.
- 54 Tortolero X, Masani K, Maluly C, Popovic MR. Body movement induced by electrical stimulation of toe muscles during standing. Artif Organs 2008; 32: 5–12.
- 55 Stea S, Bordini B, Viceconti M, Traina F, Cervini A, Toni A. Is laterality associated with a higher rate of hip arthroplasty on the dominant side? Artif Organs 2008; 32: 73–7.
- 56 Affatato S, Leardini W, Rocchi M, Toni A, Viceconti M. Investigation on wear of knee prostheses under fixed kinematic conditions. Artif Organs 2008; 32: 13–8.
- 57 Tsuang YH, Sun JS, Huang YC, Lu CH, Chang WH, Wang CC. Studies of photokilling of bacteria using titanium dioxide nanoparticles. Artif Organs 2008; 32: 167–74.
- 58 Do Nascimento BG, Vimieiro CB, Nagem DA, Pinotti M. Hip orthosis powered by pneumatic artificial muscle: voluntary activation in absence of myoelectrical signal. Artif Organs 2008; 32: 317–22.
- 59 Bavaresco VP, Garrido L, Batista NA, Malmonge SM, Belangero WD. Mechanical and morphological evaluation of osteochondral implants in dogs. Artif Organs 2008; 32: 310–6.
- 60 Díaz C, Schilardi P, De Mele MF. Influence of surface sub-micropattern on the adhesion of pioneer bacteria on metals. Artif Organs 2008; 32: 292–8.
- 61 Reggiani B, Cristofolini L, Taddei F, Viceconti M. Sensitivity of the primary stability of a cementless hip stem to its position and orientation. Artif Organs 2008; 32: 555–60.
- 62 Ludwig A. Results of electromyostimulation therapy in obstructive sleep apnea. Artif Organs 2008; 32: 655–8.
- 63 Nahrstaedt H, Schauer T, Shalaby R, Hesse S, Raisch J. Automatic control of a drop-foot stimulator based on angle measurement using bioimpedance. Artif Organs 2008; 32: 649–54.
- 64 Hofstoetter US, Minassian K, Hofer C, Mayr W, Rattay F, Dimitrijevic MR. Modification of reflex responses to lumbar posterior root stimulation by motor tasks in healthy subjects. Artif Organs 2008; 32: 644–8.
- 65 Sha N, Kenney LP, Heller BW, Barker AT, Howard D, Moatamedi M. A finite element model to identify electrode influence on current distribution in the skin. Artif Organs 2008; 32: 639–43.
- 66 Lawrence M, Gross GP, Lang M, Kuhn A, Keller T, Morari M. Assessment of finger forces and wrist torques for functional grasp using new multichannel textile neuroprostheses. Artif Organs 2008; 32: 634–8.
- 67 Moore LM, Fisher AG, Coulson JM, Salmons S, Jarvis JC. Real-time polymerase chain reaction to follow the response of muscle to training. Artif Organs 2008; 32: 630–3.
- 68 Davis GM, Hamzaid NA, Fornusek C. Cardiorespiratory, metabolic, and biomechanical responses during functional electrical stimulation leg exercise: health and fitness benefits. Artif Organs 2008; 32: 625–9.
- 69 Stickler Y, Martinek J, Hofer C, Rattay F. A finite element model of the electrically stimulated human thigh: changes due to denervation and training. Artif Organs 2008; 32: 620–4.
- 70 Martinek J, Stickler Y, Reichel M, Mayr W, Rattay F. A novel approach to simulate Hodgkin-Huxley-like excitation with COMSOL Multiphysics. Artif Organs 2008; 32: 614–9.
- 71 Gargiulo P, Vatnsdal B, Ingvarsson P, et al. Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation. Artif Organs 2008; 32: 609–13.
- 72 Mandl T, Meyerspeer M, Reichel M, et al. Functional electrical stimulation of long-term denervated, degenerated human skeletal muscle: estimating activation using T2-parameter magnetic resonance imaging methods. Artif Organs 2008; 32: 604–8.
- 73 Salmons S, Jarvis JC. Functional electrical stimulation of denervated muscles: an experimental evaluation. Artif Organs 2008; 32: 597–603.
- 74 Rozman J, Pećlin P. Selective stimulation of autonomic nerves and recording of electroneurograms in a canine model. Artif Organs 2008; 32: 592–6.
- 75 Donaldson N, Perkins T, Pachnis I, Vanhoest A, Demosthenous A. Design of an implant for preventing incontinence after spinal cord injury. Artif Organs 2008; 32: 586–91.
- 76 Meadows PM. Implant technology and usability. Artif Organs 2008; 32: 581–5.
- 77 Dimitrijevic MR. Clinical practice of functional electrical stimulation: from “Yesterday” to “Today.” Artif Organs 2008; 32: 577–80.
- 78 Varoto R, Barbarini ES, Cliquet A Jr. A hybrid system for upper limb movement restoration in quadriplegics. Artif Organs 2008; 32: 725–9.
- 79 Jung HJ. Effect of RGD-immobilized during pore PLLA scaffolds on chrondrocyte proliferation and ECM production. Artif Organs 2008; 32: 981–9.
- 80 Affatato S. A new method of in-vitro wear assessment of the UHMWPE tibial insert in total knee replacement. Artif Organs 2008; 32: 942–8.
- 81 Ciechanowska A, Ladyzynski P, Wojcicki JM, et al. Microdialysis technique as a monitoring system for acute complications of diabetes. Artif Organs 2008; 32: 45–51.
- 82 Vadi S, Shah SS, Budev M, Mehta AC. Spontaneous pneumothoraces post-lung transplantation. Artif Organs 2008; 32: 85–6.
- 83 Tian Q, Gomersall CD, Leung PP, et al. The adsorption of vancomycin by polyacrylonitrile, polyamide, and polysulfone hemofilters. Artif Organs 2008; 32: 81–4.
- 84 Buturovic J, Gubensek J, Cerne D, Ponikvar R. Standard citrate versus sequential citrate/anticoagulant-free anticoagulation during hemodialysis: a randomized trial. Artif Organs 2008; 32: 77–81.
- 85 Zhe XW, Tian XK, Cheng L, Wang T. Ultrafiltration capacity and peritoneal fluid kinetics in continuous ambulatory peritoneal dialysis patients. Artif Organs 2008; 32: 61–5.
- 86 Ekart R, Hojs R, Bevc S, Balon BP. Asymptomatic atherosclerosis and hypertension in nondiabetic patients with chronic kidney disease. Artif Organs 2008; 32: 220–5.
- 87 Meijers BK, Weber V, Bammens B, et al. Removal of the uremic retention solute p-cresol using fractionated plasma separation and adsorption. Artif Organs 2008; 32: 214–9.
- 88 Stojanovic M, Stojanovic D, Stefanovic V. The impact of malnutrition on mortality in patients on maintenance hemodialysis in Serbia. Artif Organs 2008; 32: 398–405.
- 89 Lee K, Lee SR, Mun CH, Min BG. Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency. Artif Organs 2008; 32: 406–11.
- 90 Zhe XW, Tian XK, Chen W, et al. Association between arterial stiffness and peritoneal small solute transport rate. Artif Organs 2008; 32: 416–9.
- 91 Lin HH, Liu YL, Liu JH, et al. Uremic pruritus, cytokines, and polymethylmethacrylate artificial kidney. Artif Organs 2008; 32: 468–72.
- 92 Lee JC, Park CY, Choi SW, et al. Comparison of a pulsatile blood pump and a peristaltic roller pump during hemoperfusion treatment in a canine model of paraquat poisoning. Artif Organs 2008; 32: 541–6.
- 93 Krieter DH, Lemke HD, Wanner C. A new synthetic dialyzer with advanced permselectivity for enhanced low-molecular weight protein removal. Artif Organs 2008; 32: 547–54.
- 94 Henrie M, Ford C, Andersen M, et al. In vitro assessment of dialysis membrane as an endotoxin transfer barrier: geometry, morphology, and permeability. Artif Organs 2008; 32: 701–10.
- 95 Hsu CY, Lee CT, Lee YJ, et al. Better sleep quality and less daytime symptoms in patients on evening hemodialysis: a questionnaire-based study. Artif Organs 2008; 32: 711–6.
- 96 Dinh DC, Recht NS, Hostetter TH, Meyer TW. Coated carbon hemoperfusion provides limited clearance of protein-bound solutes. Artif Organs 2008; 32: 717–24.
- 97 Erlenkötter A. Score model for the evaluation of dialysis membrane hemocompatibility. Artif Organs 2008; 32: 962–9.
- 98 Manca-Di-Villahermosa S. Acid-base balance and oxygen tension during dialysis in uremic patients with chronic obstructive pulmonary disease. Artif Organs 2008; 32: 937–7.
- 99 Hutchison CA. Serum free light chain removal by high cut-off hemodialysis: optimizing removal and supportive care. Artif Organs 2008; 32: 910–7.
- 100 Salgado OJ. Subcutaneous transposition of the superficial femoral artery for arterio-arterial hemodialysis: technique and results. Artif Organs 2008; 32: 969–73.
- 101 Branger B. Using detachment promoting agents for the prevention of chronic peritoneal-dialysis-associated infections. Artif Organs 2008; 32: 918–24.
- 102 Krieter DH, Hunn E, Morgenroth A, Lemke HD, Wanner C. Matching efficacy of online hemodiafiltration in simple hemodialysis mode. Artif Organs 2008; 32: 903–9.
- 103 Lenas P, Moreno A, Ikonomou L, et al. The complementarity of the technical tools of tissue engineering and the concepts of artificial organs for the design of functional bioartificial tissues. Artif Organs 2008; 32: 742–7.
- 104 Seebacher G, Grasl C, Stoiber M, et al. Biomechanical properties of decellularized porcine pulmonary valve conduits. Artif Organs 2008; 32: 28–35.
- 105 Birla R, Dhawan V, Huang YC, Lytle I, Tiranathanagul K, Brown D. Force characteristics of in vivo tissue-engineered myocardial constructs using varying cell seeding densities. Artif Organs 2008; 32: 684–91.
- 106 Giraud MN, Ayuni E, Cook S, Siepe M, Carrel TP, Tevaearai HT. Hydrogel-based engineered skeletal muscle grafts normalize heart function early after myocardial infarction. Artif Organs 2008; 32: 692–700.
- 107 Inanc B, Elcin AE, Unsal E, Balos K, Parlar A, Elcin YM. Differentiation of human embryonic stem cells on periodontal ligament fibroblasts in vitro. Artif Organs 2008; 32: 100–9.
- 108 Hirt-Burri N, Scaletta C, Gerber S, Pioletti DP, Applegate LA. Wound-healing gene family expression differences between fetal and foreskin cells used for bioengineered skin substitutes. Artif Organs 2008; 32: 509–18.
- 109 Liu P. Tissue-engineered skin containing mesenchymal stem cells improves burn wounds. Artif Organs 2008; 32: 925–31.
- 110 Mukai T, Shirahama N, Tominaga B, Ohno K, Koyama Y, Takakuda K. Development of watertight and bioabsorbable synthetic dural substitutes. Artif Organs 2008; 32: 473–83.
- 111 Yang SY, Sun JS, Liu CH, et al. Ex vivo magnetofection with magnetic nanoparticles: a novel platform for nonviral tissue engineering. Artif Organs 2008; 32: 195–204.
- 112 Poyck PP, Mareels G, Hoekstra R, et al. Enhanced oxygen availability improves liver-specific functions of the AMC bioartificial liver. Artif Organs 2008; 32: 116–26.
- 113 Vondran FW, Katenz E, Schwartlander R, et al. Isolation of primary human hepatocytes after partial hepatectomy: criteria for identification of the most promising liver specimen. Artif Organs 2008; 32: 205–13.
- 114 Rodriguez JV, Pizarro MD, Scandizzi AL, Guibert EE, Almada LL, Mamprin ME. Construction and performance of a minibioreactor suitable as experimental bioartificial liver. Artif Organs 2008; 32: 323–8.
- 115 Kinasiewicz A, Smietanka A, Dudzinski K, Chwojnowski A, Gajkowska B, Werynski A. Spongy polyethersulfone membrane for hepatocyte cultivation: studies on human hepatoma C3A cells. Artif Organs 2008; 32: 747–52.
- 116 Yang SH, Wu CC, Shih TT, Chen PQ, Lin FH. Three-dimensional culture of human nucleus pulposus cells in fibrin clot: comparisons on cellular proliferation and matrix synthesis with cells in alginate. Artif Organs 2008; 32: 70–3.
- 117 Ito Y, Adachi N, Nakamae A, Yanada S, Ochi M. Transplantation of tissue-engineered osteochondral plug using cultured chondrocytes and interconnected porous calcium hydroxyapatite ceramic cylindrical plugs to treat osteochondral defects in a rabbit model. Artif Organs 2008; 32: 36–44.
- 118 Venugopal JR, Low S, Choon AT, Kumar AB, Ramakrishna S. Nanobioengineered electrospun composite nanofibers and osteoblasts for bone regeneration. Artif Organs 2008; 32: 388–97.
- 119 Yamasaki T, Deie M, Shinomiya R, Yasunaga Y, Yanada S, Ochi M. Transplantation of meniscus regenerated by tissue engineering with a scaffold derived from a rat meniscus and mesenchymal stromal cells derived from rat bone marrow. Artif Organs 2008; 32: 519–24.
- 120 Chang CH, Lin HY, Fang HW, et al. Chondrogenesis from immortalized human mesenchymal stem cells: comparison between collagen gel and pellet culture methods. Artif Organs 2008; 32: 561–6.
- 121 Abousleiman RI, Reyes Y, McFetridge P, Sikavitsas V. The human umbilical vein: a novel scaffold for musculoskeletal soft tissue regeneration. Artif Organs 2008; 32: 735–42.
- 122 Tsukiyama S, Matsushita M, Matsumoto S, et al. Noble gene transduction into pancreatic beta-cells by singularizing islet cells with low doses of recombinant adenoviral vector. Artif Organs 2008; 32: 188–94.
- 123 Kin T, O'Neil JJ, Pawlick R, Korbutt GS, Shapiro AMJ. The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment. Artif Organs 2008; 32: 990–3.
- 124 Maemura T, Shin M, Kinoshita M, et al. A tissue-engineered stomach shows presence of proton pump and G-cells in a rat model, resulting in improved anemia following total gastrectomy. Artif Organs 2008; 32: 234–9.
- 125 Guan Y, Ou L, Hu G, et al. Tissue engineering of urethra using human vascular endothelial growth factor gene-modified bladder urothelial cells. Artif Organs 2008; 32: 91–9.
- 126 Tschoeke B, Flanagan TC, Cornelissen A, et al. Development of a composite degradable/nondegradable tissue-engineered vascular graft. Artif Organs 2008; 32: 800–9.
- 127 Sung K, Kim WG, Seo JW. Immunologically untreated fresh xenograft implantation in a pig-to-goat model. Artif Organs 2008; 32: 810–5.
- 128 Shindo S, Motohashi S, Katsu M, Kaga S, Inoue H, Matsumoto M. Coated prostheses are associated with prolonged inflammation in aortic surgery: a cost analysis. Artif Organs 2008; 32: 183–7.
- 129 Fukamachi K, Ootaki Y, Ootaki C, et al. Innovative, replaceable heart valve: concept, in vitro study, and acute in vivo study. Artif Organs 2008; 32: 226–9.
- 130 Rodas AC, Maizato MJ, Leirner AA, et al. Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol. Artif Organs 2008; 32: 272–6.
- 131 Maizato MJ, Pires MD, Canzian M, Higa OZ, Pitombo RN, Leirner AA. Histological evaluation of biocompatibility of lyophilized bovine pericardium implanted subcutaneously in rats. Artif Organs 2008; 32: 268–71.
- 132 Seabra AB, Da Silva R, De Souza GF, De Oliveira MG. Antithrombogenic polynitrosated polyester/poly(methyl methacrylate) blend for the coating of blood-contacting surfaces. Artif Organs 2008; 32: 262–7.
- 133 Rocha EA, De Souza C. The hemodynamic behavior of arterial anastomosis using fibrin sealant: experimental study in swine. Artif Organs 2008; 32: 835–9.
- 134 Vara DS. Endothelial cell retention on a viscoelastic nanocomposite vascular conduit is improved by exposure to shear stress preconditioning prior to physiological flow. Artif Organs 2008; 32: 977–80.
- 135 Huang F. In vitro and in vivo characterization of a silk fibroin coated polyester vascular prosthesis. Artif Organs 2008; 32: 932–41.
- 136 Chai X, Zhang L, Li W, Shao F, Yang K, Ren Q. Study of tactile perception based on phosphene positioning using simulated prosthetic vision. Artif Organs 2008; 32: 110–5.