Volume 27, Issue 12 pp. e154-e160
Original Article

Simplified procedure for the immediate loading of a complete fixed prosthesis supported by four implants in the maxillary jaw: a 2-year prospective study

Sergio Piano

Sergio Piano

Private practice, Genova, Italy

Search for more papers by this author
Eugenio Romeo

Eugenio Romeo

Department of Prosthodontics, Dental Clinic, School of Dentistry, University of Milan, Milan, Italy

Search for more papers by this author
Luca Sbricoli

Luca Sbricoli

Department of Oral Surgery, Dental Clinic, School of Dentistry, University of Padova, Padova, Italy

Search for more papers by this author
Gianluca Pisoni

Gianluca Pisoni

Department of Prosthodontics, Dental Clinic, School of Dentistry, University of Milan, Milan, Italy

Search for more papers by this author
Niccoló Cea

Niccoló Cea

Department of Prosthodontics, Dental Clinic, School of Dentistry, University of Milan, Milan, Italy

Search for more papers by this author
Diego Lops

Corresponding Author

Diego Lops

Department of Prosthodontics, Dental Clinic, School of Dentistry, University of Milan, Milan, Italy

Corresponding author:

Diego Lops

Department of Prosthodontics

Dental Clinic

School of Dentistry

University of Milan

Via Beldiletto 1/3 20142

Milano, Italy

Tel.: 0250319039/338 4897463

Fax: 0250319040

e-mails: [email protected]; [email protected]

Search for more papers by this author
First published: 24 March 2015
Citations: 10

Abstract

Purpose

The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years.

Material and methods

Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed.

Results

Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was −0.34 mm (SD of −0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed.

Conclusions

It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.