Volume 105, Issue 3 pp. 655-663

The effect of sample size on fresh plasma thromboplastin ISI determination

L. Poller

L. Poller

Central Facility, ECAA, Department of Biological Sciences, University of Manchester, U.K.,

Search for more papers by this author
A. M. H. P. Van Den Besselaar

A. M. H. P. Van Den Besselaar

Haemostasis and Thrombosis Research Centre, Leiden University Medical Centre, The Netherlands,

Search for more papers by this author
J. Jespersen

J. Jespersen

Department of Clinical Biochemistry, Centralsygehuset, Esbjerg, Denmark,

Search for more papers by this author
A. Tripodi

A. Tripodi

A. Bianchi Bonomi, Haemophilia and Thrombosis Centre, University & IRCCS Maggiore Hospital, Milan, Italy

Search for more papers by this author
D. Houghton

D. Houghton

Central Facility, ECAA, Department of Biological Sciences, University of Manchester, U.K.,

Search for more papers by this author
for European Concerted Action on Anticoagulation

for European Concerted Action on Anticoagulation

Central Facility, ECAA, Department of Biological Sciences, University of Manchester, U.K.,

Search for more papers by this author
First published: 25 December 2001
Citations: 12
Professor L. Poller, University of Manchester, Stopford Building, Oxford Road, Manchester M13 9PT.

Abstract

The possibility of reduction of numbers of fresh coumarin and normal plasmas has been studied in a multicentre manual prothrombin (PT) calibration of high international sensitivity index (ISI) rabbit and low ISI human reference thromboplastins at 14 laboratories. The number of calibrant plasmas was reduced progressively by a computer program which generated random numbers to provide 1000 different selections for each reduced sample at each participant laboratory. Results were compared with those of the full set of 20 normal and 60 coumarin plasma calibrations. With the human reagent, 20 coumarins and seven normals still achieved the W.H.O. precision limit (3% CV of the slope), but with the rabbit reagent reduction < 50 coumarins with 17 normal plasmas led to unacceptable CV. Little reduction of numbers from the full set of 80 fresh plasmas appears advisable. For maximum confidence, when calibrating the ISI of a new reagent, it would always seem worthwhile to use the full number of patients' and normal plasmas at each centre for the initial calibration, i.e. 60 fresh coumarin and 20 fresh normal plasmas. Smaller numbers should achieve the required precision with the lower ISI reagent.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.