Volume 19, Issue 3 pp. 359-364
Article
Free Access

Regional material properties of the human hip joint capsule ligaments

John Hewitt

John Hewitt

Division of Orthopaedic Surgery, Department of Surgery, Orthopaedic Research Laboratories, Duke University Medical Center, Box 3332 Durham, NC 27710, USA

Search for more papers by this author
Farshid Guilak

Farshid Guilak

Division of Orthopaedic Surgery, Department of Surgery, Orthopaedic Research Laboratories, Duke University Medical Center, Box 3332 Durham, NC 27710, USA

Search for more papers by this author
Richard Glisson

Richard Glisson

Division of Orthopaedic Surgery, Department of Surgery, Orthopaedic Research Laboratories, Duke University Medical Center, Box 3332 Durham, NC 27710, USA

Search for more papers by this author
T. Parker Vail

Corresponding Author

T. Parker Vail

Division of Orthopaedic Surgery, Department of Surgery, Orthopaedic Research Laboratories, Duke University Medical Center, Box 3332 Durham, NC 27710, USA

Division of Orthopaedic Surgery, Department of Surgery, Orthopaedic Research Laboratories, Duke University Medical Center, Box 3332 Durham, NC 27710, USA, Tel.: +1-919-684-6166; fax: + 1-919-681-7795Search for more papers by this author
First published: 01 January 2006
Citations: 156

Abstract

The hip joint capsule functions to constrain translation between the femur and acetabulum while allowing rotational and planar movements. Despite the crucial role it plays in the pathogenesis of hip instability, little is known about its biomechanical properties. The goal of this study was to determine the regional material properties of the iliofemoral and ischiofemoral ligaments of the capsule.

Ten human cadaveric specimens of each ligament were tested to failure in tension. The stress at failure, strain at failure, strain energy density at failure, toe- and linear-region elastic moduli, and the Poisson's ratio were measured for each ligament.

The strain to failure was greatest in the ischiofemoral ligament, while no significant difference was noted in failure stress by region or ligament. The Young's moduli of elasticity ranged from 76.1 to 285.8 MPa among the different ligaments, and were generally consistent with properties previously reported for the shoulder capsule. The elastic moduli and strain energy density at failure differed by region. No significant differences in Poisson's ratio were found by region or ligament. The average Poisson's ratio was approximately 1.4, consistent with anisotropic behavior of ligamentous tissues.

Understanding the material properties of the hip capsule may help the orthopaedic surgeon better understand normal ligament function, and thereby choose a surgical approach or strategy of repair. Furthermore, knowledge of the normal mechanical function of the hip capsule ligaments could assist in the evaluation of the success of a repair. © 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.