Volume 14, Issue 2 pp. 347-354
RESEARCH ARTICLE

Design of a new dual mesh with an absorbable nanofiber layer as a potential implant for abdominal hernia treatment

Mehmet Kaya

Mehmet Kaya

Department of Polymer Engineering, Yalova University Faculty of Engineering, Yalova, Turkey

Search for more papers by this author
Zehra Betul Ahi

Zehra Betul Ahi

Department of Polymer Engineering, Yalova University Faculty of Engineering, Yalova, Turkey

Search for more papers by this author
Emre Ergene

Emre Ergene

Department of Biomedical Engineering, Ankara University Faculty of Engineering, Ankara, Turkey

Search for more papers by this author
Pinar Yilgor Huri

Pinar Yilgor Huri

Department of Biomedical Engineering, Ankara University Faculty of Engineering, Ankara, Turkey

Search for more papers by this author
Kadriye Tuzlakoglu

Corresponding Author

Kadriye Tuzlakoglu

Department of Polymer Engineering, Yalova University Faculty of Engineering, Yalova, Turkey

Correspondence

Kadriye Tuzlakoglu, Department of Polymer Engineering, Yalova University Faculty of Engineering, Yalova, Turkey.

Email: [email protected]

Search for more papers by this author
First published: 11 December 2019
Citations: 12

Abstract

Dual meshes are often preferred in the treatment of umbilical and incisional hernias where the abdominal wall defect is large. These meshes are generally composed of either two nonabsorbable layers or a nonabsorbable layer combined with an absorbable one that degrades within the body upon healing of the defect. The most crucial point in the design of a dual mesh is to produce the respective layers based on the structure and requirements of the recipient site. We herein developed a dual mesh that consists of two layers: a nanofibrous layer made of poly (glycerol sebacate)/poly (caprolactone) (PGS/PCL) to support the healing of the abdominal wall defect and a nondegradable, nonadhesive smooth layer made of polycarbonateurethane (PU) with suitable properties to avoid the adhesion of the viscera to the mesh. To prepare the double-sided structure, PGS/PCL was directly electrospun onto the PU film. This processing approach provided a final product with well-integrated layers as observed by a scanning electron microscope. Tensile test performed at the dry state of the samples showed that the dual mesh has the ability to elongate seven times more as compared with the commercially available counterparts, mimicking the native tissue properties. The degradation test carried out at physiological conditions revealed that PGS started to degrade within the first 15 days. in vitro studies with human umbilical vein endothelial cells demonstrated the double function of the meshes, in which PU layer did not allow cell adhesion, whereas PGS/PCL layer has the ability to support cell adhesion and proliferation. Therefore, the material developed in this study has the potential to be an alternative to the existing hernia mesh products.

CONFLICT OF INTEREST

The authors have declared that there is no conflict of interest.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.