Optimal design of a pair of vibration suppression devices for a multi-storey building
Sara Ying Zhang
Institute of Urban Smart Transportation and Safety Maintenance, Shenzhen University, Shenzhen, China
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Search for more papers by this authorSimon Neild
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Search for more papers by this authorCorresponding Author
Jason Zheng Jiang
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Correspondence
Jason Zheng Jiang, Department of Mechanical Engineering, University of Bristol, Bristol, UK.
Email: [email protected]
Search for more papers by this authorSara Ying Zhang
Institute of Urban Smart Transportation and Safety Maintenance, Shenzhen University, Shenzhen, China
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Search for more papers by this authorSimon Neild
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Search for more papers by this authorCorresponding Author
Jason Zheng Jiang
Department of Mechanical Engineering, University of Bristol, Bristol, UK
Correspondence
Jason Zheng Jiang, Department of Mechanical Engineering, University of Bristol, Bristol, UK.
Email: [email protected]
Search for more papers by this authorSummary
This paper investigates the use of two two-terminal vibration suppression devices in a building and assesses the performance benefits over those achieved using a single device. The inerter-combined configurations for a multi-storey building structure are considered. The inerter is a two-terminal device, with the property that the applied force is proportional to the relative acceleration across its terminals. In this paper, a five-storey building model with two absorbers of the same kind subjected to base excitation is studied, where one is located between ground and the first floor and the other is between the first and second floors of the building. Three passive suppression layouts, two dampers, two tuned inerter dampers, and two tuned viscous mass dampers are considered. The optimal configurations for minimising the maximum interstorey drifts of the building are obtained with respect to the inerter's size and the damping boundary. The corresponding parameter values are also presented. For the sake of comparison, the single device mounted between the ground and first floor is also considered. Finally, with specific inertance and damping values, the frequency response is provided to show the potential advantage of the proposed optimal configurations. It is demonstrated that the optimal configurations with a pair of devices are more effective than the optimal single device with equal total inertance and the same total damping boundary. The approach demonstrated in this paper is applicable to the investigation of using more than two devices for multistorey buildings.
REFERENCES
- 1Frahm H. Device for Damping Vibrations of Bodies; 1909.
- 2DenHartog JP. Mechanical Vibration. York, PA, USA:McGraw Hill; 1940.
- 3Fujino Y, Abe M. Design formulas for tuned mass dampers based on a perturbation technique. Earthq Eng Struct D. 1993; 22: 833–854.
- 4Moutinho C. An alternative methodology for designing tuned mass dampers to reduce seismic vibrations in building structures. Earthq Eng Struct D. 2012; 41: 2059–2073.
- 5Angelis MD, Perno S, Reggio A. Dynamic response and optimal design of structures with large mass ratio TMD. Earthq Eng Struct D. 2012; 41: 41–60.
- 6Krenk S. Frequency analysis of the tuned mass damper. J Appl Mech. 2005; 72: 936–942.
- 7Villaverde R. Reduction in seismic response with heavily-damped vibration absorbers. Earthq Eng Struct D. 1985; 13: 33–42.
- 8Sadek F, Mohraz B, Taylor AW, Chung RM. A method of estimating the parameters of tuned mass damper for seismic applications. Earthq Eng Struct D. 1997; 26: 617–635.
- 9Iwanami K, Seto K. Optimum design of dual tuned mass dampers and their effectiveness. P JSME(C). 1984; 50: 44–52.
10.1299/kikaic.50.44 Google Scholar
- 10Li C. Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground acceleration. Earthq Eng Struct D. 2000; 29: 1405–1421.
- 11Igusa T, Xu K. Vibration control using multiple tuned mass damper. J Sound Vib. 1994; 175: 491–503.
- 12Kareem A, Kline S. Performance of multiple mass dampers under random loading. J Struct Eng. 1995; 121: 348–361.
- 13Moon KS. Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design. The Struct Des Tall and Spec. 2010; 19: 347–366.
- 14Fu TS, Johnson EA. Distributed mass damper system for integrating structural and environmental controls in buildings. J Eng Mech. 2011; 137: 205–213.
- 15Tong X, Zhao XW. Vibration suppression of the finite-dimensional approximation of the non-uniform SCOLEmodel using multiple tuned mass dampersIEEE 55th Conference on Decision and Control (CDC); 2016.
- 16Rana R, Soong TT. Parametric study and simplified design of tuned mass dampers. Eng Struct. 1998; 20: 193–204.
- 17Xiang P, Nishitani A. Seismic vibration control of building structures with multiple tuned mass damper floors integrated. Earthq Eng Struct D. 2014; 43: 909–925.
- 18Takewaki I. Optimal damper placement for minimum transfer functions. Earthq Eng Struct D. 1997; 26: 1113–1124.
- 19Smith MC. Synthesis of mechanical networks: the inerter. IEEE T Automat Contr. 2002; 47: 1648–1662.
- 20Papageorgiou C, Smith MC. Positive real synthesis using matrix inequalities for mechanical networks: application to vehicle suspension. IEEE T Contr Syst T. 2006; 14: 423–435.
- 21Smith MC, Wang FC. Performance benefits in passive vehicle suspensions employing inerters. Vehicle Syst Dyn. 2004; 42: 235–237.
- 22Smith MC. http://www.eng.cam.ac.uk/news/stories/2008/mclaren; [19 August,2008].
- 23Evangelou S, Limebeer DJN, Sharp RS, Smith MC. Mechanical steering compensation for high-performance motorcycles. J Appl Mech. 2007; 74: 332–346.
- 24Jiang JZ, Smith MC, Houghton NE. Experimental testing and modelling of a mechanical steering compensator. In: The 3rd International Symposium on Communications, Control and Signal Processing (ISCCSP); 2007.
- 25Wang FC, Liao MK, Liao BH, Su WJ, Chan HA. The performance improvements of train suspension systems with mechanical networks employing inerters. Vehicle Syst Dyn. 2009; 47: 805–830.
- 26Jiang JZ, Matamoros-Sanchez AZ, Goodall RM, Smith MC. Passive suspensions incorporating inerters for railway vehicles. Vehicle Syst Dyn. 2011; 50: 263–276.
- 27Li Y, Jiang JZ, Neild S. Inerter-based configurations for main landing gear shimmy suppression. J Aircraft. 2016; 54: 684–693.
- 28Zhu M, Zhang SY, Jiang JZ, Macdonald J, Neild S. Enhancing the dynamic performance of a pantograph-catenary system via inerter-based damping technologyInternational Conference on Noise and Vibration Engineering; 2018.
- 29Li YY, Zhang SY, Jiang JZ, Neild S, Ward I. Passive vibration control of offshore wind turbines using the structure-immittance approachInternational Conference on Noise and Vibration Engineering; 2018.
- 30Wang FC, Su WJ, Chen CW. Building suspensions with inerters. P I Mech Eng C-J Mec. 2010; 224: 1650–1616.
- 31Ikago K, Saito K, Inoue N. Seismic control of single-degree-of-freedom structure using tuned viscous mass damper. Earthq Eng Struct D. 2012; 41: 453–474.
- 32Marian L, Giaralis A. Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems. Probabilistic Eng Mech. 2014; 38: 156–164.
- 33Zhang SY, Jiang JZ, Neild SA. Optimal configurations for a linear vibration suppression device in a multi-storey building. Struct Control Health Monit. 2016; 24:e1887.
- 34Lu L, Duan YF, Spencer Jr BF, Lu XL, Zhou Y. Inertial mass damper for mitigating cable vibration. Struct Control Health Monit. 2016; 24:e1986.
- 35Gonzalez-Buelga A, Lazar IF, Jiang JZ, Neild SA, Inman DJ. Assessing the effect of nonlinearities on the performance of a tuned inerter damper. Struct Control Health Monit. 2016; 33:e1879.
- 36Ikago K, Sugimura Y, Saito K, Inoue N. Seismic displacement control of multiple-degree-of-freedom structures using tuned viscious mass dampers. In: Proceedings of the 8th international conference on structural dynamics; 2011; Leuven, Belgium.
- 37Takewaki I, Murakami S, Yoshitomi S, Tsuji M. Fundamental mechanism of earthquake response reduction in building structures with inertial dampers. Struct Control Health Monit. 2012; 19: 590–608.
- 38Giaralis A, Marian L. Use of inerter devices for weight reduction of tuned-mass-dampers for seismic protection of multi-story building: the tuned mass-damper-interter (TMDI). SPIE 9799, Active and Passive Smart Structures and Integrated Systems https://doi.org/10.1117/12.2219324; 2016.
- 39Warburton GB. Optimum absorber parameters for various combinations of response and excitation parameters. Earthq Eng Struct D. 1982; 10: 381–401.
- 40Shearer JL, Murphy AT, Richardson HH. Introduction to System Dynamics. USA:Addison-Wesley; 1967.
- 41Xiang P, Nishitani A. Optimum design of tuned mass damper floor system integrated into bending-shear type building based on H∞, H2, and stability maximization criteria. Struct Control Health Monit. 2015; 22: 919–938.
- 42Lazar IF, Neild SA, Wagg DJ. Using an inerter-based device for structural vibration suppression. Earthq Eng Struct D. 2014; 43: 1129–1147.
- 43Makris N, Constantinou MC. Viscous dampers: Testing, modeling and application in vibration and seismic, New York, National Center for Earthquake Engineering Research; 1990.
- 44Singh M, Moreschi L. Optimal seismic response control with dampers. Earthq Eng Struct D. 2001; 30: 553–572.
- 45Trombetti T, Silvestri S. On the modal damping ratios of shear-type structures equipped with Rayleigh damping systems. J Sound Vib. 2006; 292: 21–58.
- 46Trombetti T, Silvestri S. Novel schemes for inserting seismic dampers in shear-type systems based upon the mass proportional component of the Rayleigh damping matrix. J Sound Vib. 2007; 302: 486–526.
- 47Chen Z, Junya K, Masahiro I, Kohju I, Norio I. Viscoelastically supported viscous mass damper incorporated into a seismic isolation system. J Earthq Tsunami. 2016; 10:1640009. https://doi.org/10.1142/S1793431116400091