Volume 64, Issue 6 pp. 1704-1712
Imaging Methodology-Full Papers

Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues

Mario Ries

Corresponding Author

Mario Ries

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

UMR 5231, Imagerie Moléculaire et Fonctionnelle, Université “Victor Segalen” Bordeaux 2 146, rue Léo Saignat, case 117 33076 Bordeaux, France===Search for more papers by this author
Baudouin Denis de Senneville

Baudouin Denis de Senneville

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

Search for more papers by this author
Sébastien Roujol

Sébastien Roujol

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

LaBRI, UMR 5800 CNRS/Université Bordeaux 1, Talence, France

Search for more papers by this author
Yasmina Berber

Yasmina Berber

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

Search for more papers by this author
Bruno Quesson

Bruno Quesson

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

Search for more papers by this author
Chrit Moonen

Chrit Moonen

Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, UMR 5231 CNRS/University Bordeaux 2, 146 Rue Leo Saignat, Bordeaux, France

Search for more papers by this author
First published: 27 September 2010
Citations: 105

Abstract

Magnetic resonance imaging-guided high intensity focused ultrasound is a promising method for the noninvasive ablation of pathological tissue in abdominal organs such as liver and kidney. Due to the high perfusion rates of these organs, sustained sonications are required to achieve a sufficiently high temperature elevation to induce necrosis. However, the constant displacement of the target due to the respiratory cycle render continuous ablations challenging, since dynamic repositioning of the focal point is required. This study demonstrates subsecond 3D high intensity focused ultrasound-beam steering under magnetic resonance-guidance for the real-time compensation of respiratory motion. The target is observed in 3D space by coupling rapid 2D magnetic resonance-imaging with prospective slice tracking based on pencil-beam navigator echoes. The magnetic resonance-data is processed in real-time by a computationally efficient reconstruction pipeline, which provides the position, the temperature and the thermal dose on-the-fly, and which feeds corrections into the high intensity focused ultrasound-ablator. The effect of the residual update latency is reduced by using a 3D Kalman-predictor for trajectory anticipation. The suggested method is characterized with phantom experiments and verified in vivo on porcine kidney. The results show that for update frequencies of more than 10 Hz and latencies of less then 114 msec, temperature elevations can be achieved, which are comparable to static experiments. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.