Volume 7, Issue 6 pp. 945-949
Original Research
Full Access

SPIO-enhanced 2D-TOF MR angiography of the portal venous system: Results of an intraindividual comparison

Peter Reimer MD

Corresponding Author

Peter Reimer MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, GermanySearch for more papers by this author
Christian Marx MD

Christian Marx MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Ernst J. Rummeny MD

Ernst J. Rummeny MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Markus Müller MD

Markus Müller MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Markus Lentschig MD

Markus Lentschig MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Thomas Balzer MD

Thomas Balzer MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Karl-Heinz Dietl MD

Karl-Heinz Dietl MD

Department of Surgery, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Udo Sulkowski MD

Udo Sulkowski MD

Department of Surgery, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
Thomas Berns MD

Thomas Berns MD

Department of Surgery, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Schering AG, Berlin, Germany

Search for more papers by this author
Kohkan Shamsi MD

Kohkan Shamsi MD

Schering AG, Berlin, Germany

Search for more papers by this author
Peter E. Peters MD

Peter E. Peters MD

Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Albert-Schweitzer Straße 33, D-48129 Münster, Germany

Search for more papers by this author
First published: 17 November 2005
Citations: 34

Abstract

The purpose of this study was to investigate whether MR angiography (MRA) of the portal venous system may be improved by means of superparamagnetic iron oxides (SPIOs) during accumulation phase imaging and to study the underlying contrast mechanisms. MRA of the portal venous system was performed on 48 patients before and after intravenous injection of a new SPIO (Resovist, Schering AG, Berlin, Germany). Resovist, as a predominantly liver parenchymal darkening agent on T2-weighted MR images with uptake into the reticuloendothelial cell system, was administered intravenously by bolus injection of 8 to 12 μmol Fe/kg body weight. Patients were scanned with breath-hold coronal and axial two-dimensional (2D) time of flight (TOF) MRA (TR = 31.0 msec, TE = 9.8 msec, flip angle (FA) = 50°, and 6.9-second acquisition time per section) sequences. Signal intensity values of liver parenchyma, the portal venous system, and background were obtained for quantitative analysis. The clinical relevance of additional plain and contrast-enhanced MRA studies for surgical planning was assessed by independent reading of three readers. Liver signal-to-noise ratio (SNR) significantly decreased following iv injection of Resovist; however, SNR values of the portal veins or hepatic veins did not change significantly. Visibility of the portal venous system improved significantly (tertiary branches visible: pre in 15.2% versus post in 87.0% of patients). Resovist-enhanced 2D-TOF MRA may improve planning of liver resections by better demonstrating the relationship of central liver lesions and vessels on source images. The decrease in liver SNR at a constant vessel SNR after iv injection of Resovist improves MRA of the liver. SPIO-enhanced 2D-TOF MRA scans are superior to plain 2D-TOF MRA studies and may be added for the workup of preoperative patients.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.