Volume 9, Issue 7 pp. 1053-1064
Article
Full Access

Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry

T. Yoshikawa

T. Yoshikawa

Department of Anatomy, Indiana University Medical Center, Indianapolis, Indiana

Search for more papers by this author
C.H. Turner

C.H. Turner

Department of Orthopaedic Surgery, Indiana University Medical Center, Indianapolis, Indiana

Department of Mechanical Engineering, Indiana University Medical Center, Indianapolis, Indiana

Search for more papers by this author
M. Peacock

M. Peacock

Department of Medicine, Indiana University Medical Center, Indianapolis, Indiana

Search for more papers by this author
C.W. Slemenda

C.W. Slemenda

Department of Medicine, Indiana University Medical Center, Indianapolis, Indiana

Search for more papers by this author
C.M. Weaver

C.M. Weaver

Department of Food and Nutrition, Purdue University, West Lafayette, Indiana

Search for more papers by this author
D. Teegarden

D. Teegarden

Department of Food and Nutrition, Purdue University, West Lafayette, Indiana

Search for more papers by this author
P. Markwardt

P. Markwardt

Lunar Corporation, Madison, Wisconsin

Search for more papers by this author
D.B. Burr Ph.D.

Corresponding Author

D.B. Burr Ph.D.

Department of Anatomy, Indiana University Medical Center, Indianapolis, Indiana

Department of Orthopaedic Surgery, Indiana University Medical Center, Indianapolis, Indiana

Department of Anatomy Medical Science Building 259 Indiana University Medical Center 635 Barnhill Drive Indianapolis, IN 46202Search for more papers by this author
First published: July 1994
Citations: 186

Abstract

An algorithm was developed to estimate the strength of the femoral neck from data generated by the dual-energy x-ray absorptiometry (DXA). This algorithm considers shape of the proximal femur as well as cross-sectional moment of inertia (CSMI) in the estimate. Proximal femora (10) from cadavers of white adults and an aluminum step wedge were scanned with the Lunar DPX to validate the calculation of CSMI. After scanning, each femoral neck was sectioned at its narrowest portion for direct measurement of CSMI. Three healthy young women were scanned five times each to evaluate the reproducibility of geometric measurements using DXA. There was a strong linear association between the CSMI measured directly and using DXA in both cadaver bones (r2 = 0.96) and the aluminum step wedge (r2 = 0.99). The coefficient of variation for CSMI from repeated measurements using DXA was less than 3%. This indicates that it is possible to estimate reproducibly the bending rigidity of bone from DXA measurements. The data from 306 normal subjects were analyzed to investigate geometric changes in the femoral neck with age. Although there was no strong correlation between CSMI and age in normal subjects of either sex, safety factor (SF, an index of strength of the femoral neck during walking) and fall index (FI, an index of the strength of the femoral neck during a fall) decrease with age in both sexes. We observed an alteration of the geometric structure of the femoral neck with age that may increase the stress on the femoral neck and decrease SF and FI.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.