Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stent
Corresponding Author
Masood Sadiq
Punjab Institute of Cardiology, Lahore, Pakistan
The Institute of Child Health/The Children's Hospital, Department of Congenital Heart Disease, Punjab Institute of Cardiology, Ghaus-ul-Azam (Jail) Road, Lahore, PakistanSearch for more papers by this authorNadeem Hayat Malick
Punjab Institute of Cardiology, Lahore, Pakistan
Search for more papers by this authorShakeel A. Qureshi
Department of Congenital Heart Disease, Guy's Hospital, London, U.K
Search for more papers by this authorCorresponding Author
Masood Sadiq
Punjab Institute of Cardiology, Lahore, Pakistan
The Institute of Child Health/The Children's Hospital, Department of Congenital Heart Disease, Punjab Institute of Cardiology, Ghaus-ul-Azam (Jail) Road, Lahore, PakistanSearch for more papers by this authorNadeem Hayat Malick
Punjab Institute of Cardiology, Lahore, Pakistan
Search for more papers by this authorShakeel A. Qureshi
Department of Congenital Heart Disease, Guy's Hospital, London, U.K
Search for more papers by this authorAbstract
A 19-year-old girl with coarctation of the aorta and patent ductus arteriosus underwent simultaneous treatment of native coarctation and closure of ductus arteriosus using a covered Cheatham-Platinum stent. This technique may be used as an alternative to other forms of interventional therapy or surgery for this combination of lesions in adolescents and adults. Cathet Cardiovasc Intervent 2003;59:387–390. © 2003 Wiley-Liss, Inc.
REFERENCES
- 1 Okubo M, Benson L. Intravascular and intracardiac stents used in congenital heart disease. Curr Opin Cardiol 2001; 16: 84–91.
- 2 Magee AG, Brzezinska-Rajszys, Qureshi SA, et al. Stent implantation for aortic coarctation and recoarctation. Heart 1999; 82: 600–606.
- 3 Thanopoulous BD, Hadjinikolou L, Konstadopoulou GN, Tsaousis GS, Triposkiadis F, Spirou P. Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerations. Heart 2000; 84: 65–70.
- 4 Fyler DC, Buckley LP, Hellenbrand WE, Cohen HE. Report of the new England regional infant cardiac program. Paediatrics 1980; 65: 376–461.
- 5
Hakim F,
Hawelleh AA,
Goussous Y,
Hijazi ZM.
Simultaneous stent implantation for coarctation of the aorta and closure of patent ductus arteriosus using the Amplatzer duct occluder.
Cathet Cardiovasc Intervent
1999;
47:
36–38.
10.1002/(SICI)1522-726X(199905)47:1<36::AID-CCD6>3.0.CO;2-Q CAS PubMed Web of Science® Google Scholar
- 6 Gunn J, Cleveland T, Gaines P. Covered stent to treat coexistent coarctation and aneurysm of the aorta in a young man. Heart 1999; 82: 351.
- 7 de Giovanni JV. Covered stents in the treatment of aortic coarctation. J Intervent Cardiol 2001; 14: 187–190.
- 8
Rosenthal E,
Qureshi SA,
Kakadekar AP,
Persaud D,
Tabatabaie AH,
Baker EJ,
Tynan M.
Stent characteristics for preservation of arterial duct patency: experimental evaluation.
Cardiol Young
1995;
5:
331–337.
10.1017/S1047951100002791 Google Scholar
- 9
Cheatham JP.
Stents and Amplatzers: what's an interventionalist to do?
Catheter Cardiovasc Intervent
1999;
47:
39–40.
10.1002/(SICI)1522-726X(199905)47:1<39::AID-CCD7>3.0.CO;2-E CAS PubMed Web of Science® Google Scholar
- 10 Huggon IC, Qureshi SA, Baker EJ, Tynan M. Effect of introducing balloon dilation of native aortic coarctation on overall outcome in infants and children. Am J Cardiol 1994; 73: 799–807.
- 11 Galal O, al-Fadley F, Wilson N. Successful transcatheter closure of patent arterial duct six years after balloon dilation of coarctation of the aorta. Int J Cardiol 1992; 35: 123–125.
- 12 Hamdan MA, Maheshwari S, Fahey JT, Hellenbrand WE. Endovascular stents for coarctation of the aorta: initial results and intermediate term follow up. J Am Coll Cardiol 2001; 38: 1518–1523.
- 13 Ovaert C, Benson LN, Nykanen D, Freedom R. Transcatheter treatment of coarctation of the aorta: a review. Pediatr Cardiol 1998; 19: 27–44.
- 14 Ebeid MR, Prieto LR, Latson LA. Use of balloon-expandable stents for coarctation of the aorta: initial results and intermediate-term follow-up. J Am Coll Cardiol 1997; 30: 1847–1852.
- 15 Suarez de Lezo J, Pan M, Romero M, et al. Balloon-expandable stent repair of severe coarctation of aorta. Am Heart J 1995; 129: 1002–1008.
- 16 Suarez de Lezo J, Pan M, Romero M, et al. Immediate and follow-up findings after stent treatment for severe coarctation of aorta. Am J Cardiol 1999; 83: 400–406.
- 17 Khan MS, Moore JW. Treatment of abdominal aortic pseudoaneurysm with covered stents in a paediatric patient. Cathet Cardiovasc Intervent 2000; 50: 445–448.
- 18 Taylor PR, Gaines PA, McGuinness CL, Beard JD, Cooper G, Reidy JF. Thoracic aortic stent grafts: early experience from two centres using commercially available devices. Eur J Vasc Endovasc Surg 2001; 22: 70–76.
- 19 Wada T, Yao H, Miyamoto T, Mukai S, Yamamura M. Prevention and detection of spinal cord injury during thoracic and thoraco-abdominal aortic repairs. Ann Thorac Surg 2001; 72: 80–84.
- 20 Connolly JE. Prevention of spinal cord complications in aortic surgery. Am J Surg 1998; 176: 92–101.