Viscosity Measurements on NaCl in the Temperature Range 1083 — 1473 K
Abstract
enThe viscosity of NaCl has been measured with an oscillating-cup viscometer in the temperature range from 1083 K to 1473 K along the saturation line. The measured viscosity was lower than a currently recommended value by nearly 40%, whereas it was in accordance with other recent experimental results. To evaluate a meniscus effect of the liquid inside the cup on the viscosity, an experimental assessment was made. The results showed no appreciable viscosity change caused by changing the height of the liquid surface. The Stokes-Einstein equation was further examined for NaCl using the present results. While an excellent agreement between the calculated self-diffusion coefficient and that of experiment was observed for the cation, the calculated value was systematically lower than the experimental one for the anion.
Abstract
deDie Viskosität von NaCl wurde mit einem Oszillationsviskometer im Temperaturbereich von 1083 K bis 1473 K unter dem Gleichgewichts-Dampfdruck gemessen. Die gemessene Viskosität war um 40% niedriger als der in der Literatur angenommene Wert, stimmt aber mit neuen experimentellen Daten anderer Autoren überein. Der Meniskuseinfluß auf die Viskosität wurde experimentell untersucht. Aus Messungen mit verschiedenen Flüssigkeitshöhen folgt, daß dieser Einfluß gering ist. Die Werte für die Selbstdiffusionskoeffizienten, die sich aus der Anwendung der Stokes-Einstein-Gleichung auf die experimentellen Viskositätsdaten ergeben, stimmen mit den experimentellen Werten für das Kation überein, liegen aber für das Anion niedriger.