A 1-Year Prospective Study on Co-Axis® Implants Immediately Loaded with a Full Ceramic Crown
Stefan Vandeweghe DDS
Dentist, PhD student, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorJan Cosyn DDS, MSc, PhD
periodontist, professor, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorEric Thevissen DDS, MSc
periodontist, PhD student, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorLinda Van den Berghe DDS, MSc, PhD
prosthodontist, professor, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorCorresponding Author
Hugo De Bruyn DDS, MSc, PhD
periodontist, professor, chairman of the department, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Professor Dr Hugo De Bruyn, Department of Periodontology & Oral Implantology, University Hospital of Ghent – P8, De Pintelaan 185, 9000 Ghent, Belgium; e-mail: [email protected]Search for more papers by this authorStefan Vandeweghe DDS
Dentist, PhD student, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorJan Cosyn DDS, MSc, PhD
periodontist, professor, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorEric Thevissen DDS, MSc
periodontist, PhD student, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorLinda Van den Berghe DDS, MSc, PhD
prosthodontist, professor, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Search for more papers by this authorCorresponding Author
Hugo De Bruyn DDS, MSc, PhD
periodontist, professor, chairman of the department, Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
Professor Dr Hugo De Bruyn, Department of Periodontology & Oral Implantology, University Hospital of Ghent – P8, De Pintelaan 185, 9000 Ghent, Belgium; e-mail: [email protected]Search for more papers by this authorABSTRACT
Introduction: The Co-Axis® implant (Southern Implants®, Irene, South Africa) has a 12-degree angle in the implant neck to overcome angulation problems.
Aim: To examine bone loss, peri-implant health, and aesthetical outcome after 1-year follow-up.
Materials and Methods: Fifteen single implants were placed in 14 patients in the premaxilla and immediately loaded with a screw-retained full ceramic crown. Periapical radiographs and standardized photographs were taken to determine bone loss and soft tissue changes. Plaque and bleeding levels were assessed. Patients' satisfaction was measured using the Oral Health Impact Profile-14 questionnaire.
Results: After 1 year, all implants survived and mean bone loss was 1.20 mm, with no significant changes after 6 months. Plaque levels were low and no significant changes were observed. Bleeding levels decreased during the initial 3 months, but were constant thereafter. Before final torqueing was performed after 6 months, four cases of screw loosening occurred. Also, one crown had a piece of porcelain chipped off. Patients reported an overall increase in well-being. A mean midfacial recession of 0.37 mm was observed. The mesial papilla showed a slight increase of 0.14 mm, while the distal papilla decreased 0.35 mm.
Conclusion: With 100% survival and stable bone levels after 6 months, the Co-Axis implant showed a good clinical outcome when immediately loaded. The use of a full ceramic crown as a first and final restoration resulted in a good aesthetic outcome with few changes in papilla fill, although midfacial soft tissue was stable only after 1 year.
REFERENCES
- 1 Andersson B, Odman P, Carlsson GE. A study of 184 consecutive patients referred for single-tooth replacement. Clin Oral Implants Res 1995; 6: 232–237.
- 2 Brägger U, Krenander P, Lang NP. Economic aspects of single-tooth replacement. Clin Oral Implants Res 2005; 16: 335–341.
- 3 Mericske-Stern R, Grutter L, Rosch R, Mericske E. Clinical evaluation and prosthetic complications of single tooth replacements by non-submerged implants. Clin Oral Implants Res 2001; 12: 309–318.
- 4 Priest G. Single-tooth implants and their role in preserving remaining teeth: a 10-year survival study. Int J Oral Maxillofac Implants 1999; 14: 181–188.
- 5 Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997; 8: 161–172.
- 6 Jemt T. Single implants in the anterior maxilla after 15 years of follow-up: comparison with central implants in the edentulous maxilla. Int J Prosthodont 2008; 21: 400–408.
- 7 Jemt T. Cemented CeraOne and porcelain fused to TiAdapt abutment single-implant crown restorations: a 10-year comparative follow-up study. Clin Implant Dent Relat Res 2009; 11: 303–310.
- 8 Wennstrom JL, Ekestubbe A, Grondahl K, Karlsson S, Lindhe J. Implant-supported single-tooth restorations: a 5-year prospective study. J Clin Periodontol 2005; 32: 567–574.
- 9 Mayer TM, Hawley CE, Gunsolley JC, Feldman S. The single-tooth implant: a viable alternative for single-tooth replacement. J Periodontol 2002; 73: 687–693.
- 10 Buser D, Martin W, Belser UC. Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants 2004; 19 (Suppl 7): 43–61.
- 11 Hermann JS, Buser D, Schenk RK, Schoolfield JD, Cochran DL. Biologic Width around one- and two-piece titanium implants. Clin Oral Implants Res 2001; 12: 559–571.
- 12 Tarnow DP, Cho SC, Wallace SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontol 2000; 71: 546–549.
- 13 Tarnow DP, Magner AW, Fletcher P. The effect of the distance from the contact point to the crest of bone on the presence or absence of the interproximal dental papilla. J Periodontol 1992; 63: 995–996.
- 14 Van der Weijden F, Dell'Acqua F, Slot DE. Alveolar bone dimensional changes of post-extraction sockets in humans: a systematic review. J Clin Periodontol 2009; 36: 1048–1058.
- 15 Andersen E, Haanaes HR, Knutsen BM. Immediate loading of single-tooth ITI implants in the anterior maxilla: a prospective 5-year pilot study. Clin Oral Implants Res 2002; 13: 281–287.
- 16 Drago CJ, Lazzara RJ. Immediate provisional restoration of Osseotite implants: a clinical report of 18-month results. Int J Oral Maxillofac Implants 2004; 19: 534–541.
- 17 Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004; 15: 428–434.
- 18 Lindeboom JA, Frenken JW, Dubois L, Frank M, Abbink I, Kroon FH. Immediate loading versus immediate provisionalization of maxillary single-tooth replacements: a prospective randomized study with BioComp implants. J Oral Maxillofac Surg 2006; 64: 936–942.
- 19 Norton MR. A short-term clinical evaluation of immediately restored maxillary TiOblast single-tooth implants. Int J Oral Maxillofac Implants 2004; 19: 274–281.
- 20 Abrahamsson I, Berglundh T, Lindhe J. The mucosal barrier following abutment dis/reconnection. An experimental study in dogs. J Clin Periodontol 1997; 24: 568–572.
- 21 Atieh MA, Payne AG, Duncan WJ, Cullinan MP. Immediate restoration/loading of immediately placed single implants: is it an effective bimodal approach? Clin Oral Implants Res 2009; 20: 645–659.
- 22 Kan JY, Rungcharassaeng K, Lozada J. Immediate placement and provisionalization of maxillary anterior single implants: 1-year prospective study. Int J Oral Maxillofac Implants 2003; 18: 31–39.
- 23 Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol 1998; 25: 721–727.
- 24 Rompen E, Domken O, Degidi M, Pontes AE, Piattelli A. The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: a literature review. Clin Oral Implants Res 2006; 17(Suppl 2): 55–67.
- 25 Albrektsson T, Isidor F. Consensus report of session IV. London: Quintessence, 1993.
- 26 Mombelli A, van Oosten MA, Schurch E Jr, Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987; 2: 145–151.
- 27 Slade GD. Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol 1997; 25: 284–290.
- 28 Locker D. Measuring oral health: a conceptual framework. Community Dent Health 1988; 5: 3–18.
- 29 Furhauser R, Florescu D, Benesch T, Haas R, Mailath G, Watzek G. Evaluation of soft tissue around single-tooth implant crowns: the pink esthetic score. Clin Oral Implants Res 2005; 16: 639–644.
- 30 Belser UC, Grutter L, Vailati F, Bornstein MM, Weber HP, Buser D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J Periodontol 2009; 80: 140–151.
- 31 Branemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977; 16: 1–132.
- 32 Piattelli A, Corigliano M, Scarano A, Costigliola G, Paolantonio M. Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys. J Periodontol 1998; 69: 321–327.
- 33 Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000; 11: 12–25.
- 34 Cooper LF, Rahman A, Moriarty J, Chaffee N, Sacco D. Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and loading. Int J Oral Maxillofac Implants 2002; 17: 517–525.
- 35 Ibanez JC, Jalbout ZN. Immediate loading of osseotite implants: two-year results. Implant Dent 2002; 11: 128–136.
- 36 Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997; 12: 319–324.
- 37 Calandriello R, Tomatis M, Rangert B. Immediate functional loading of Branemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study. Clin Implant Dent Relat Res 2003; 5(Suppl 1): 10–20.
- 38 Calandriello R, Tomatis M, Vallone R, Rangert B, Gottlow J. Immediate occlusal loading of single lower molars using Branemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study. Clin Implant Dent Relat Res 2003; 5(Suppl 1): 74–80.
- 39 Chaushu G, Chaushu S, Tzohar A, Dayan D. Immediate loading of single-tooth implants: immediate versus non-immediate implantation. A clinical report. Int J Oral Maxillofac Implants 2001; 16: 267–272.
- 40 Cornelini R, Cangini F, Covani U, Barone A, Buser D. Immediate restoration of single-tooth implants in mandibular molar sites: a 12-month preliminary report. Int J Oral Maxillofac Implants 2004; 19: 855–860.
- 41 Glauser R, Ree A, Lundgren A, Gottlow J, Hammerle CH, Scharer P. Immediate occlusal loading of Branemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res 2001; 3: 204–213.
- 42 Rocci A, Martignoni M, Gottlow J. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study. Clin Implant Dent Relat Res 2003; 5(Suppl 1): 29–36.
- 43 Degidi M, Piattelli A, Carinci F. Parallel screw cylinder implants: comparative analysis between immediate loading and two-stage healing of 1,005 dental implants with a 2-year follow up. Clin Implant Dent Relat Res 2006; 8: 151–160.
- 44 Ericsson I, Nilson H, Lindh T, Nilner K, Randow K. Immediate functional loading of Branemark single tooth implants. An 18 months' clinical pilot follow-up study. Clin Oral Implants Res 2000; 11: 26–33.
- 45 Hall JA, Payne AG, Purton DG, Torr B, Duncan WJ, De Silva RK. Immediately restored, single-tapered implants in the anterior maxilla: prosthodontic and aesthetic outcomes after 1 years. Clin Implant Dent Relat Res 2007; 9: 34–45.
- 46 Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Branemark dental implants. An 18-month clinical follow-up study. Clin Oral Implants Res 1999; 10: 8–15.
- 47 Schnitman PA, Wohrle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997; 12: 495–503.
- 48 Ottoni JM, Oliveira ZF, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants 2005; 20: 769–776.
- 49 Atieh MA, Atieh AH, Payne AG, Duncan WJ. Immediate loading with single implant crowns: a systematic review and meta-analysis. Int J Prosthodont 2009; 22: 378–387.
- 50 Agliardi E, Panigatti S, Clerico M, Villa C, Malo P. Immediate rehabilitation of the edentulous jaws with full fixed prostheses supported by four implants: interim results of a single cohort prospective study. Clin Oral Implants Res 2010; 21: 459–465.
- 51 Koutouzis T, Wennstrom JL. Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study. Clin Oral Implants Res 2007; 18: 585–590.
- 52 Nothdurft FP, Doppler KE, Erdelt KJ, Knauber AW, Pospiech PR. Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns. Clin Oral Investig 2011; 15: 157–163.
- 53 Berglundh T, Abrahamsson I, Lindhe J. Bone reactions to longstanding functional load at implants: an experimental study in dogs. J Clin Periodontol 2005; 32: 925–932.
- 54 Collaert B, De Bruyn H. Immediate functional loading of TiOblast dental implants in full-arch edentulous maxillae: a 3-year prospective study. Clin Oral Implants Res 2008; 19: 1254–1260.
- 55 Cooper L, Felton DA, Kugelberg CF, et al. A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery. Int J Oral Maxillofac Implants 2001; 16: 182–192.
- 56 Degidi M, Piattelli A, Gehrke P, Felice P, Carinci F. Five-year outcome of 111 immediate nonfunctional single restorations. J Oral Implantol 2006; 32: 277–285.
- 57 Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent 1988; 59: 59–63.
- 58 Salvi GE, Lang NP. Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofac Implants 2004; 19(Suppl 7): 116–127.
- 59 Ulmer FC. The Hawthorne effect. Educ Dir Dent Aux 1976; 1: 28.
- 60 Chaytor DV, Zarb GA, Schmitt A, Lewis DW. The longitudinal effectiveness of osseointegrated dental implants. The Toronto Study: bone level changes. Int J Periodontics Restorative Dent 1991; 11: 112–125.
- 61 Lekholm U, Ericsson I, Adell R, Slots J. The condition of the soft tissues at tooth and fixture abutments supporting fixed bridges. A microbiological and histological study. J Clin Periodontol 1986; 13: 558–562.
- 62 Jepsen S, Ruhling A, Jepsen K, Ohlenbusch B, Albers HK. Progressive peri-implantitis. Incidence and prediction of peri-implant attachment loss. Clin Oral Implants Res 1996; 7: 133–142.
- 63 Lang NP, Wetzel AC, Stich H, Caffesse RG. Histologic probe penetration in healthy and inflamed peri-implant tissues. Clin Oral Implants Res 1994; 5: 191–201.
- 64 Cho SC, Small PN, Elian N, Tarnow D. Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data. Implant Dent 2004; 13: 245–250.
- 65 Pjetursson BE, Karoussis I, Burgin W, Bragger U, Lang NP. Patients' satisfaction following implant therapy. A 10-year prospective cohort study. Clin Oral Implants Res 2005; 16: 185–193.
- 66 de Bruyn H, Collaert B, Linden U, Bjorn AL. Patient's opinion and treatment outcome of fixed rehabilitation on Branemark implants. A 3-year follow-up study in private dental practices. Clin Oral Implants Res 1997; 8: 265–271.
- 67 Dierens M, Collaert B, Deschepper E, Browaeys H, Klinge B, De Bruyn H. Patient-centered outcome of immediately loaded implants in the rehabilitation of fully edentulous jaws. Clin Oral Implants Res 2009; 20: 1070–1077.
- 68 Berretin-Felix G, Nary Filho H, Padovani CR, Machado WM. A longitudinal study of quality of life of elderly with mandibular implant-supported fixed prostheses. Clin Oral Implants Res 2008; 19: 704–708.
- 69 Jokstad A. Implant retained or conventional dentures, which give more patients satisfaction? Evid Based Dent 2006; 7: 96–97.
- 70 De Rouck T, Collys K, Cosyn J. Immediate single-tooth implants in the anterior maxilla: a 1-year case cohort study on hard and soft tissue response. J Clin Periodontol 2008; 35: 649–657.
- 71 Donati M, La Scala V, Billi M, Di Dino B, Torrisi P, Berglundh T. Immediate functional loading of implants in single tooth replacement: a prospective clinical multicenter study. Clin Oral Implants Res 2008; 19: 740–748.