Volume 36, Issue 12 pp. 1389-1390
Video Article
Free Access

Failed endoscopic ultrasound-guided gallbladder drainage across the duodenal covered metallic stent salvaged by using a forward-viewing linear echoendoscope

Tesshin Ban

Corresponding Author

Tesshin Ban

Department of Gastroenterology and Hepatology, Gamagori City Hospital, Aichi, Japan

Corresponding: Tesshin Ban, Department of Gastroenterology and Hepatology, Gamagori City Hospital, 1-1 Mukaida, Hirata, Gamagori, Aichi 443-8501, Japan. Email: [email protected]

Search for more papers by this author
Yoshimasa Kubota

Yoshimasa Kubota

Department of Gastroenterology and Hepatology, Gamagori City Hospital, Aichi, Japan

Search for more papers by this author
Takashi Joh

Takashi Joh

Department of Gastroenterology and Hepatology, Gamagori City Hospital, Aichi, Japan

Search for more papers by this author
First published: 18 September 2024

Abstract

Watch a video of this article.

BRIEF EXPLANATION

Endoscopic ultrasonography-guided gallbladder drainage (EUS-GBD) has emerged as an alternative to standard percutaneous or transpapillary approaches in fragile patients with acute cholecystitis.1-3 Oblique-viewing linear endoscopic ultrasonography (OV-EUS) is used for biliary intervention. However, forward-viewing linear endoscopic ultrasonography (FV-EUS) is applied in certain settings.4, 5 Herein, we report salvaged EUS-GBD by using FV-EUS after failure of OV-EUS.

An 82-year-old man with clinical stage IV pancreatic cancer presented with severe vomiting and initially underwent implantation of a duodenal bulb-covered metallic stent. One week later, this patient underwent endoscopic ultrasonography-guided choledochoduodenostomy due to acute obstructive suppurative cholangitis without intrahepatic biliary dilation (Video S1). One month later, this patient developed antibiotic-refractory acute cholecystitis, which deteriorated into a pericholecystic abscess (Fig. 1). Prioritizing the internal drainage, we attempted EUS-GBD using OV-EUS (EG-580UT; Fujifilm, Tokyo, Japan). The gallbladder was depicted; however, the scope struggled to maneuver in the duodenal metallic stent, and a 19G lancet puncture needle could not advance from the scope channel into the gallbladder (Fig. 2a, Video S1). The following day, we retried EUS-GBD using FV-EUS (TGF-UC260J; Olympus, Tokyo, Japan), which quickly facilitated the gallbladder visualization, needle puncture, 0.025 inch hydrophilic guidewire advancement, electrocautery dilation (Cysto-Gastro-Sets; Endo-flex, Voerde, Germany), and a double-pigtailed plastic stent deployment (Advanix J, 7F, 7 cm; Boston Scientific, Marlborough, MA, USA) (Fig. 2b,c, Video S1). The clinical course was uneventful.

Details are in the caption following the image
Contrast-enhanced computed tomography (CT) image. CT reveals acute cholecystitis with pericholecystic abscess. A red arrow indicates a swollen gallbladder with wall thickness and intraluminal gas. A yellow arrow indicates the pericholecystic abscess.
Details are in the caption following the image
Endoscopic ultrasonography-guided gallbladder drainage using oblique- and forward-viewing linear endoscopic ultrasonography. (a) Oblique-viewing linear endoscopic ultrasonography. A 19G lancet puncture needle never advanced into the gallbladder from the steeply down-angled scope. The previous duodenal metallic stent also limited the scope maneuverability. (b) Forward-viewing linear endoscopic ultrasonography. A 19G lancet needle with a guidewire was smoothly advanced into the gallbladder in the straight scope position. (c) A 7F double-pigtailed plastic stent was deployed across the duodenal metallic stent into the gallbladder.

The maneuverability of the OV-EUS was limited inside the duodenal bulb stent. We needed to down-angle the scope steeply to depict the gallbladder, which obstructed the puncture needle. In this situation, FV-EUS in the long position easily depicted the gallbladder without an angle maneuver. In addition, all the devices showed excellent pushability and trackability, including the puncture needle, dilator, and gallbladder stent, because the target was located vertically in front of the long-positioned FV-EUS.5

Authors declare no conflict of interest for this article.