Usefulness of a precisely controllable through-the-scope clip for duodenal diverticular bleeding

Takeshi Uozumi

Corresponding Author

Takeshi Uozumi

Department of Gastroenterology, Tonan Hospital, Hokkaido, Japan

Corresponding: Takeshi Uozumi, Department of Gastroenterology, Tonan Hospital, Kita 4, Nishi 7, Chuo-ku, Sapporo, Hokkaido 060-0004, Japan. Email: [email protected]

Search for more papers by this author
Kei Yane

Kei Yane

Department of Gastroenterology, Tonan Hospital, Hokkaido, Japan

Search for more papers by this author
Tetsuya Sumiyoshi

Tetsuya Sumiyoshi

Department of Gastroenterology, Tonan Hospital, Hokkaido, Japan

Search for more papers by this author
First published: 14 July 2020
Citations: 1

Abstract

Watch a video of this article

Brief Explanation

Duodenal diverticular bleeding (DDB) is an uncommon cause of upper gastrointestinal bleeding. A duodenal diverticulum (DD) is a pseudodiverticulum without a muscle layer and therefore structurally fragile. Thus, the optimal treatment for DDB remains controversial.1, 2 Pinpoint hemostasis at the bleeding point is crucial to prevent diffuse tissue injury and perforation. To achieve this, we used a transparent hood and a through-the-scope clip. The transparent hood enabled us to maintain distance from the target and prevent mucosal injury by shielding the clip.2 The SureClip (Micro-Tech Co, Nanjing, China) is a through-the-scope clip (TTSC) that can be repositioned before deployment and rotated more precisely than other TTSCs at any scope angle due to its flexible delivery catheter.3 This clip facilitates accurate release at the target due to its unique design.4 Here, we report the first case of successfully using the SureClip for hemostasis of DDB. An 85-year-old man was admitted to our hospital because of hematemesis and severe anemia. He had a history of heart disease and was taking oral warfarin and aspirin. Esophagogastroduodenoscopy was performed using a scope with a transparent hood at the tip of the endoscope (GIF-H290T: Olympus, Tokyo, Japan); DD was detected in the second portion. A small diverticulum was present in the DD, and active bleeding was observed at the edge of the small diverticulum (Fig. 1). Concerned that electrical coagulation could potentially cause tissue injury and subsequent perforation, we elected to attempt clipping. We were able to precisely rotate and reposition the SureClip in the diverticulum and successfully achieve hemostasis (Fig. 2a–c, Video S1). Second-look endoscopy was performed 3 days later and showed no evidence of rebleeding (Fig. 2d). The SureClip can be manipulated freely in a confined space; therefore, it is a useful treatment modality for achieving appropriate hemostasis in DDB.

Details are in the caption following the image
(a) A small diverticulum existed in the duodenal diverticulum. Active bleeding was observed at the edge of the small diverticulum. (b) The exposed vessel was detected (yellow arrow).
Details are in the caption following the image
(a, b) The SureClip could be repositioned before deployment. (c) The SureClip could be rotated 90° in the duodenal diverticulum without overshooting. (d) Second-look endoscopy showed successful clip placement and no rebleeding.

Authors declare no conflicts of interest for this article..