Clinical study on survival rate of short implants placed in the posterior mandibular region: resonance frequency analysis
Corresponding Author
Thallita P. Queiroz
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Corresponding author:
Thallita P. Queiroz
Av. José Bonifácio, 128, CEP:14801-150
Araraquara, SP, Brazil
Tel./Fax: +55 16 3335-3603
e-mail: [email protected]
Search for more papers by this authorSamuel C. Aguiar
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorRogério Margonar
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorAna P. de Souza Faloni
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorReinhard Gruber
Laboratory of Oral Cell Biology, School of Dental Medicine, University of Bern, Bern, Switzerland
Search for more papers by this authorEloá R. Luvizuto
Department of Surgery and Integrated Clinic, Araçatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, Brazil
Search for more papers by this authorCorresponding Author
Thallita P. Queiroz
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Corresponding author:
Thallita P. Queiroz
Av. José Bonifácio, 128, CEP:14801-150
Araraquara, SP, Brazil
Tel./Fax: +55 16 3335-3603
e-mail: [email protected]
Search for more papers by this authorSamuel C. Aguiar
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorRogério Margonar
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorAna P. de Souza Faloni
Department of Health Sciences, Implantology Post Graduation Course, Dental School, University Center of Araraquara – UNIARA, São Paulo, Brazil
Search for more papers by this authorReinhard Gruber
Laboratory of Oral Cell Biology, School of Dental Medicine, University of Bern, Bern, Switzerland
Search for more papers by this authorEloá R. Luvizuto
Department of Surgery and Integrated Clinic, Araçatuba Dental School, UNESP-Univ Estadual Paulista, Araçatuba, Brazil
Search for more papers by this authorAbstract
Objective
Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible.
Material and methods
Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days).
Results
The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall.
Conclusions
Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.
References
- Abrahamsson, I., Linder, E. & Lang, N.P. (2009) Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clinical Oral Implants Research 20: 313–318.
- Anitua, E., Piña, L., Begoña, L. & Orive, G. (2014) Long-term retrospective evaluation of short implants in the posterior areas: clinical results after 10–12 years. Journal of Clinical Periodontology 41: 404–411.
- Annibali, S., Cristalli, M.P., Dell'Aquila, D., Bignozzi, I., La Monaca, G. & Pilloni, A. (2012) Short dental implants: a systematic review. Journal of Dental Research 91: 25–32.
- Arlin, M.L. (2006) Short dental implants as a treatment option: results from an observational study in a single private practice. The International Journal of Oral & Maxillofacial Implants 21: 769–776.
- Atieh, M.A., Alsabeeha, N.H.M. & Payne, A.G.T. (2012) Can resonance frequency analysis predict failure risk of immediately loaded implants? The International Journal of Prosthodontics 25: 326–339.
- Atieh, M.A., Alsabeeha, N.H.M., Payne, A.G.T., de Silva, R.K., Schwass, D.S. & Duncan, W.J. (2014) The prognostic accuracy of resonance frequency analysis in predicting failure risk of immediately restored implants. Clinical Oral Implants Research 25: 29–35.
- Bahat, O. (1993) Treatment planning and placement of implants in the posterior maxillae: report of 732 consecutive Nobelpharma implants. The International Journal of Oral & Maxillofacial Implants 8: 151–161.
- Balevi, B. (2013) In selected sites, short, rough-surfaced dental implants are as successful as long dental implants: a critical summary of Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta-analysis of observational studies. J Clin Periodontol 2011;38(9):856–863. The Journal of the American Dental Association 144: 195–196.
- Becker, W., Sennerby, L., Bedrossian, E., Becker, B.E. & Lucchini, J.P. (2005) Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial. Journal of Periodontology 76: 391–397.
- Bischof, M., Nedir, R., Abi Najm, S., Szmukler-Moncler, S. & Samson, J. (2006) five-year life-table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice. Clinical Oral Implants Research 17: 512–520.
- Bischof, M., Nedir, R., Szmukler-Moncler, S., Bernard, J.P. & Samson, J. (2004) Implant stability measurement of delayed and immediately loaded implants during healing. Clinical Oral Implants Research 15: 529–539.
- Boronat López, A., Balaguer Martínez, J., Lamas Pelayo, J., Carrillo García, C. & Peñarrocha Diago, M. (2008) Resonance frequency analysis of dental implant stability during the healing period. Medicina Oral Patología Oral y Cirurgía Bucal 13: E244–E247.
- Brocard, D., Barthet, P., Baysse, E., Duffort, J.F., Eller, P., Justumus, P., Marin, P., Oscaby, F., Simonet, T., Benque, E. & Brunel, G. (2000) A multicenter report on 1022 consecutively placed ITI implants: a 7-year longitudinal study. The International Journal of Oral & Maxillofacial Implants 15: 691–700.
- ten Bruggenkate, C.M., Asikainen, P., Foitzik, C., Krekeler, G. & Sutter, F. (1998) Short (6-mm) nonsubmerged dental implants: results of a Multicenter clinical trial of 1 to 7 years. The International Journal of Oral & Maxillofacial Implants 13: 791–798.
- Buser, D., Mericske-Stern, R., Bernard, J.P., Behneke, A., Behneke, N., Hirt, H.P., Belser, U.C. & Lang, N.P. (1997) Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clinical Oral Implants Research 8: 161–172.
- Buser, D., Weber, H.P., Bragger, U. & Balsiger, C. (1994) Tissue integration of one-stage implants: three-year results of a prospective longitudinal study with hollow cylinder and hollow screw implants. Quintessence International 25: 679–686.
- Carvalho, A.C., Queiroz, T.P., Okamoto, R., Margonar, R., Garcia, I.R., Jr & Magro Filho, O. (2011) Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias. The International Journal of Oral & Maxillofacial Implants 26: 1193–1201.
- Da Cunha, H.A., Francischone, C.E., Filho, H.N. & de Oliveira, R.C. (2004) A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. The International Journal of Oral & Maxillofacial Implants 19: 578–585.
- De Santis, D., Cucchi, A., Rigoni, G. & Longhi, C. (2013) Short implants with oxidized surface in posterior areas of atrophic jaws: 3- to 5-year results of a multicenter study. Clinical Implant Dentistry and Related Research 17: 442–452.
- De Smet, E., Jaecques, S., Vandamme, K., Vander Sloten, J. & Naert, I. (2005) Positive effect of early loading on implant stability in the bi-cortical guinea-pig model. Clinical Oral Implants Research 16: 402–407.
- Deporter, D. (2013) Short dental implants: what works and what doesn't? A literature interpretation. The International Journal of Periodontics and Restorative Dentistry 33: 457–464.
- Engquist, B., Astrand, P., Anzén, B., Dahlgren, S., Engquist, E., Feldmann, H., Karlsson, U., Nord, P.G., Sahlholm, S. & Svärdström, P. (2005) Simplified methods of implant treatment in the edentulous lower jaw: a 3-year follow-up report of a controlled prospective study of one-stage vs. two-stage surgery and early loading. Clinical Implant Dentistry and Related Research 7: 95–104.
- Felice, P., Pistilli, R., Piattelli, M., Soardi, E., Corvino, V. & Esposito, M. (2012) Posterior atrophic jaws rehabilitated with prostheses supported by 5 x 5 mm implants with a novel nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. Preliminary results from a randomised controlled trial. European Journal of Oral Implantology 5: 149–161.
- Feng, S.W., Lin, C.T., Chang, W.J., Lee, S.Y., Cheng, C.H. & Huang, H.M. (2014) Influence of simulated bone quality and cortical bone thickness on implant stability detection using resonance frequency and damping factor analysis. The International Journal of Oral & Maxillofacial Implants 29: 105–112.
- Friberg, B., Grondahl, K., Lekholm, U. & Branemark, P.I. (2000) Long-term follow-up of severely atrophic edentulous mandibles reconstructed with short Branemark implants. Clinical Implant Dentistry and Related Research 2: 184–189.
- Fugazzotto, P.A. (2008) Shorter implants in clinical practice: rationale and treatment results. The International Journal of Oral & Maxillofacial Implants 23: 487–496.
- Geckili, O., Bilhan, H., Geckili, E., Cilingir, A., Mumcu, E. & Bural, C. (2013) Evaluation of possible prognostic factors for the success, survival, and failure of dental implants. Implant Dentistry 23: 44–50.
- Glauser, R., Sennerby, L., Meredith, N., Rée, A., Lundgren, A., Gottlow, J. & Hämmerle, C.H. (2004) Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clinical Oral Implants Research 15: 428–434.
- Goene, R., Bianchesi, C., Huerzeler, M., Del Lupo, R., Testori, T., Davarpanah, M. & Jalbout, Z. (2005) Performance of short implants in partial restorations: 3-year follow-up of Osseotite implants. Implant Dentistry 14: 274–280.
- Griffin, T.J. & Cheung, W.S. (2004) The use of short, wide implants in posterior areas with reduced bone height: a retrospective investigation. The Journal of Prosthetic Dentistry 92: 139–144.
- Guler, A.U., Sumer, M., Duran, I., Sandikci, E.O. & Telcioglu, N.T. (2013) Resonance frequency analysis of 208 Straumann dental implants during the healing period. Journal of Oral Implantology 39: 161–167.
- Herrmann, I., Lekholm, U., Holm, S. & Kultje, C. (2005) Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. The International Journal of Oral & Maxillofacial Implants 20: 220–230.
- Huwiler, M.A., Pjetursson, B.E., Bosshardt, D.D., Salvi, G.E. & Lang, N.P. (2007) Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clinical Oral Implants Research 18: 275–280.
- Kessler-Liechti, G., Zix, J. & Mericske-Stern, R. (2008) Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis. The International Journal of Oral & Maxillofacial Implants 23: 353–358.
- Kim, S.J., Ribeiro, A.L.V.L., Atlas, A.M., Saleh, N., Royal, J., Radvar, M. & Korostoff, J. (2013) Resonance frequency analysis as a predictor of early implant failure in the partially edentulous posterior maxilla following immediate nonfunctional loading or delayed loading with single unit restorations. Clinical Oral Implants Research 26: 183–190.
- Kotsovilis, S., Fourmousis, I., Karoussis, I.K. & Bamia, C. (2009) A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants. Journal of Periodontology 80: 1700–1718.
- Kumar, V.V., Sagheb, K., Klein, M.O., Al-Nawas, B., Kann, P.H. & Kämmerer, P.W. (2012) Relation between bone quality values from ultrasound transmission velocity and implant stability parameters–an ex vivo study. Clinical Oral Implants Research 23: 975–980.
- Langer, B., Langer, L., Herrmann, I. & Jorneus, L. (1993) The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1. International Journal of Oral & Maxillofacial Implants 8: 400–408.
- Levin, L. (2008) Dealing with dental implant failures. Journal of Applied Oral Science 16: 171–175.
- Mangano, F.G., Shibli, J.A., Sammons, R.L., Iaculli, F., Piattelli, A. & Mangano, C. (2013) Short (8-mm) locking-taper implants supporting single crowns in posterior region: a prospective clinical study with 1-to 10-years of follow-up. Clinical Oral Implants Research 25: 933–940.
- McDermott, N.E., Chuang, S.K., Woo, V.V. & Dodson, T.B. (2003) Complications of dental implants: identification, frequency, and associated risk factors. The International Journal of Oral & Maxillofacial Implants 18: 848–855.
- Meredith, N. (1998) Assessment of implant stability as a prognostic determinant. The International Journal of Prosthodontics 11: 491–501.
- Meredith, N., Alleyne, D. & Cawley, P. (1996) Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clinical Oral Implants Research 7: 261–267.
- Morand, M. & Irinakis, T. (2007) The challenge of implant therapy in the posterior maxilla: providing a rationale for the use of short implants. The Journal of Oral Implantology 33: 257–266.
- Neldam, C.A. & Pinholt, E.M. (2012) State of the art of short dental implants: a systematic review of the literature. Clinical Implant Dentistry and Related Research 14: 622–632.
- das Neves, F.D., Fones, D., Bernardes, S.R., do Prado, C.J. & Neto, A.J. (2006) Short implants–an analysis of longitudinal studies. The International Journal of Oral & Maxillofacial Implants 21: 86–93.
- Pjetursson, B.E., Rast, C., Bragger, U., Schmidlin, K., Zwahlen, M. & Lang, N.P. (2009) Maxillary sinus floor elevation using the (transalveolar) osteotome technique with or without grafting material. Part I: implant survival and patients’ perception. Clinical Oral Implants Research 20: 667–676.
- Pjetursson, B.E., Tan, K., Lang, N.P., Bragger, U., Egger, M. & Zwahlen, M. (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clinical Oral Implants Research 15: 625–642.
- Polizzi, G., Rangert, B., Lekholm, U., Gualini, F. & Lindstrom, H. (2000) Branemark system wide platform implants for single molar replacement: clinical evaluation of prospective and retrospective materials. Clinical Implant Dentistry and Related Research 2: 61–69.
- Pommer, B., Frantal, S., Willer, J., Posch, M., Watzek, G. & Tepper, G. (2011) Impact of dental implant length on early failure rates: a meta-analysis of observational studies. Journal of Clinical Periodontology 38: 856–863.
- Porter, J.A. & von Fraunhofer, J.A. (2005) Success or failure of dental implants? A literature review with treatment considerations General Dentistry 53: 423–432; quiz 433, 446.
- Queiroz, T.P., Souza, F.A., Okamoto, R., Margonar, R., Pereira-Filho, V.A., Garcia Junior, I.R. & Vieira, E.H. (2008) Evaluation of immediate bone-cell viability and of drill wear after implant osteotomies: immunohistochemistry and scanning electron microscopy analysis. Journal of Oral and Maxillofacial Surgery 66: 1233–1240.
- Ratajczak, T. (2011) Guidelines: Short and angulated implants. Presented at the 6th Annual European Consensus Conference, Cologne, Germany, March 2011.
- Renouard, F., Arnoux, J.P. & Sarment, D.P. (1999) Five-mm-diameter implants without a smooth surface collar: report on 98 consecutive placements. The International Journal of Prosthodontics 14: 101–107.
- Renouard, F. & Nisand, D. (2005) Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clinical Implant Dentistry and Related Research 7(Suppl 1): S104–S110.
- Rodrigo, D., Aracil, L., Martin, C. & Sanz, M. (2010) Diagnosis of implant stability and its impact on implant survival: a prospective case series study. Clinical Oral Implants Research 21: 255–261.
- Romeo, E., Lops, D., Margutti, E., Ghisolfi, M., Chiapasco, M. & Vogel, G. (2004) Long-term survival and success of oral implants in the treatment of full and partial arches: a 7-year prospective study with the ITI dental implant system. The International Journal of Oral & Maxillofacial Implants 19: 247–259.
- Rossi, F., Ricci, E., Marchetti, C., Lang, N.P. & Botticelli, D. (2010) Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study. Clinical Oral Implants Research 21: 937–943.
- dos Santos, P.L., Queiroz, T.P., Margonar, R., de Souza, G., Carvalho, A.C., Okamoto, R., de Souza Faloni, A.P. & Garcia, I.R., Jr. (2013) Guided implant surgery: what is the influence of this new technique on bone cell viability? Journal of Oral and Maxillofacial Surgery 71: 505–512.
- Sennerby, L. & Meredith, N. (2008) Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontology 2000 47: 51–66.
- Sennerby, L., Andersson, P., Pagliani, L., Giani, C., Moretti, G., Molinari, M. & Motroni, A. (2013) Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability. Clinical Oral Implants Research doi: 10.1111/cid.12193. [Epub ahead of print].
10.1111/cid.12193 Google Scholar
- Sennerby, L. & Roos, J. (1998) Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. The International Journal of Prosthodontics 11: 408–420.
- Shibly, O., Kutkut, A., Patel, N. & Albandar, J.M. (2012) Immediate implants with immediate loading vs. conventional loading: 1-year randomized clinical trial. Clinical Implant Dentistry Related Research 14: 663–671.
- Sim, C.P. & Lang, N.P. (2010) Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clinical Oral Implants Research 21: 598–604.
- Stacchi, C., Vercellotti, T., Torelli, L., Furlan, F. & Di Lenarda, R. (2013) Changes in implant stability using different site preparation techniques: twist drills vs. piezosurgery. A single-blinded, randomized, controlled clinical trial. Clinical Implant Dentistry and Related Research 15: 188–197.
- Stellingsma, C., Vissink, A., Meijer, H.J., Kuiper, C. & Raghoebar, G.M. (2004) Implantology and the severely resorbed edentulous mandible. Critical Reviews in Oral Biology and Medicine 15: 240–248.
- Suzuki, E.Y., Suzuki, B., Aramrattana, A., Harnsiriwattanakit, K. & Kowanich, N. (2010) Assessment of miniscrew implant stability by resonance frequency analysis: a study in human cadavers. Journal of Oral and Maxillofacial Surgery 68: 2682–2689.
- Van Assche, N., Michels, S., Quirynen, M. & Naert, I. (2012) Extra short dental implants supporting an overdenture in the edentulous maxilla: a proof of concept. Clinical Oral Implants Research 23: 567–576.
- Zix, J., Kessler-Liechti, G. & Mericske-Stern, R. (2005) Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. The International Journal of Oral & Maxillofacial Implants 20: 747–752.
- Zix, J., Hug, S., Kessler-Liechti, G. & Mericske-Stern, R. (2008) Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. The International Journal of Oral & Maxillofacial Implants 23: 525–530.