Volume 42, Issue 9 1 pp. 3000-3007
Original Scientific Report

A Novel Wound Retractor Combining Continuous Irrigation and Barrier Protection Reduces Incisional Contamination in Colorectal Surgery

Harry T. Papaconstantinou

Corresponding Author

Harry T. Papaconstantinou

Department of Surgery, Baylor Scott & White Healthcare, Texas A&M University College of Medicine, 2401 South 31st Street, Temple, TX, USA

Tel.: (254) 724-2595, [email protected]Search for more papers by this author
Rocco Ricciardi

Rocco Ricciardi

Massachusetts General Hospital, Boston, MA, USA

Department of Surgery, Lahey Hospital and Medical Center, 41 Burlington Mall Road, Burlington, MA, USA

Search for more papers by this author
David A. Margolin

David A. Margolin

Department of Colon and Rectal Surgery, University of Queensland, Ochsner Clinical School, 1514 Jefferson Highway, New Orleans, LA, USA

Search for more papers by this author
Roberto Bergamaschi

Roberto Bergamaschi

Division of Colon and Rectal Surgery, State University at Stony Brook, 101 Nicolls Road, Stony Brook, NY, USA

Search for more papers by this author
Robert C. Moesinger

Robert C. Moesinger

Northern Utah Surgeons, Intermountain Healthcare, University of Utah, 4401 Harrison Blvd, Ste 1635, Ogden, UT, USA

Search for more papers by this author
Warren E. Lichliter

Warren E. Lichliter

Baylor University Medical Center, 3500 Gaston Avenue, 1 Roberts, Dallas, TX, USA

Search for more papers by this author
Elisa H. Birnbaum

Elisa H. Birnbaum

Department of Surgery, Section of Colon and Rectal Surgery, Washington University School of Medicine, 660 S. Euclid Ave, Campus Box 8109, St. Louis, MO, USA

Search for more papers by this author
First published: 09 March 2018
Citations: 8

Abstract

Background

Surgical site infection (SSI) remains a persistent and morbid problem in colorectal surgery. Key to its pathogenesis is the degree of intraoperative bacterial contamination at the surgical site. The purpose of this study was to evaluate a novel wound retractor at reducing bacterial contamination.

Methods

A prospective multicenter pilot study utilizing a novel wound retractor combining continuous irrigation and barrier protection was conducted in patients undergoing elective colorectal resections. Culture swabs were collected from the incision edge prior to device placement and from the exposed and protected incision edge prior to device removal. The primary and secondary endpoints were the rate of enteric and overall bacterial contamination on the exposed incision edge as compared to the protected incision edge, respectively. The safety endpoint was the absence of serious device-related adverse events.

Results

A total of 86 patients were eligible for analysis. The novel wound retractor was associated with a 66% reduction in overall bacterial contamination at the protected incision edge compared to the exposed incision edge (11.9 vs. 34.5%, P < 0.001), and 71% reduction in enteric bacterial contamination (9.5% vs. 33.3%, P < 0.001). The incisional SSI rate was 2.3% in the primary analysis and 1.2% in those that completed the protocol. There were no adverse events attributed to device use.

Conclusions

A novel wound retractor combining continuous irrigation and barrier protection was associated with a significant reduction in bacterial contamination. Improved methods to counteract wound contamination represent a promising strategy for SSI prevention (NCT 02413879).

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.