Fine Structure of X-Ray Interferograms. III. Complex Interference Systems†‡
Part I and II see phys. stat. sol. (a) 54, 729 (1979) and 63, 91 (1981), respectively.
Dedicated to Prof. Dr. Dr. h. c. Dr. E. h. P. Görlich on the occasion of his 80th birthday
Mravyan str. 1, 375049 Erevan, USSR.
Abstract
enThe nature and origin of fine structure of X-ray interference patterns obtained from complex two and three-block interference systems with closely placed blocks are considered. The X-ray interference patterns are obtained and a theoretical analysis of observed fine structure is performed. It is shown that if the blocks are sufficiently close to one another and of least one of them is thick, then X-ray interference patterns can be seen without enlarger. For the first time three dynamical effects are observed simultaneously, namely, pendellösung fringes, moiré fringes, and displacement fringes.
Abstract
deDie Art und der Ursprung der Feinstruktur von Röntgen-Interferenzdiagrammen, die von komplexen Zwei- und Drei-Blockinterferenzsystemen mit dicht gepackten Blöcken erhalten werden, wird untersucht. Die Röntgeninterferenzdiagramme werden erhalten und eine theoretische Analyse der beobachteten Feinstruktur durchgeführt. Es wird gezeigt, daß wenn die Blöcke genügend eng beieinander liegen und wenigstens einer von ihnen dick ist, die Interferenzdiagramme ohne Verstärker beobachtet werden können. Erstmalig werden drei dynamische Effekte gleichzeitig beobachtet, Pendellösungsstreifen, Moirestreifen und Verschiebungsstreifen.