X-ray laue diffraction from a bent crystal integrated intensity
Abstract
enThe integrated intensity of a Laue diffraction on an elastically bent crystal is calculated analytically and numerically on the basis of Takagi's dynamical theory of diffraction for a distorted crystal. Crystal anisotropy is taken into account. The calculated values are compared with the measured ones for the nonsymmetrical Laue diffraction (111) using CuKα and MoKα radiations; μt being 0.14 to 5.6 and deformations [ε] in the range of 2 × 10−5 to 4 × 10−4. The measurements are carried out on a double crystal diffractometer in the non-dispersive arrangement. The agreement between the theoretical values and the experimental ones seems to be very good.
Abstract
deDie Abhängigkeit des integralen Reflexionsvermögens von der Deformation wird für einen homogen gebogenen Idealkristall analytisch und numerisch ausgerechnet, wobei von der analytischen Lösung der Takagischen Gleichung ausgegangen wird. Für den Fall der unsymmetrischen Lauebeugung am Si werden die berechneten Werte mit den gemessenen verglichen. Bei der Cu- und Mo-Strahlung beträgt μt 0,14 bis 5,6 und die Deformation [ε] 2 × 10−5 bis 4 × 10−4. Die Messung wird mittels Doppel-Kristall-Diffraktometer durchgeführt. Die Übereinstimmung der Theorie mit dem Experiment erscheint sehr gut.