Volume 21, Issue 2 pp. 106-111
Research Article

Data from frequency-volume charts versus filling cystometric estimated capacities and prevalence of instability in men with lower urinary tract symptoms suggestive of benign prostatic hyperplasia

Ger E.P.M. van Venrooij

Corresponding Author

Ger E.P.M. van Venrooij

Department of Urology, University Medical Center, Utrecht, The Netherlands

Department of Urology (G05.2.01), University Medical Center, P.O. Box 85500, 3508 GA Utrecht, The Netherlands.Search for more papers by this author
Mardy D. Eckhardt

Mardy D. Eckhardt

Department of Urology, University Medical Center, Utrecht, The Netherlands

Search for more papers by this author
Karel W.H. Gisolf

Karel W.H. Gisolf

Department of Urology, University Medical Center, Utrecht, The Netherlands

Search for more papers by this author
Tom A. Boon

Tom A. Boon

Department of Urology, University Medical Center, Utrecht, The Netherlands

Search for more papers by this author
First published: 08 February 2002
Citations: 18

Abstract

The aim was to examine associations of filling cystometric estimated compliance, capacities, and prevalence of bladder instability with data from frequency-volume charts in a well-defined group of men with lower urinary tract symptoms (LUTS) suggestive of benign prostatic hyperplasia (BPH). Men with LUTS suggestive of BPH were included if they met the criteria of the International Consensus Committee on BPH, i.e., they voided more than 150 mL during uroflowmetry, their residual volume and prostate size were estimated, and they completed frequency-volume charts correctly. From the frequency-volume charts, voiding habits, and fluid intake in the daytime and at night were evaluated. Filling cystometric studies were performed in these men as well. Decreased compliance was an exceptional finding. Cystometric capacity and especially effective capacity (cystometric capacity minus residual volume) corresponded significantly with the maximum voided volume on the frequency-volume charts. Effective capacity was almost twice as high as the average voided volume. Minimum voided volume on frequency-volume charts was not related to filling cystometric data. The presence of instability in the supine or sitting position or in both positions was not significantly associated with smaller voided volumes, higher nocturia, or diuria. Filling cystometric capacities were strongly associated with maximal and mean voided volumes derived from frequency-volume charts. The presence of detrusor instability during filling cystometry did not significantly affect voided volumes, diuria, or nocturia. Neurourol. Urodynam. 21:106–111, 2002. © 2002 Wiley-Liss, Inc.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.