A multispectral three-dimensional acquisition technique for imaging near metal implants
Corresponding Author
Kevin M. Koch
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
GE Healthcare, Applied Science Laboratory, 3200 N. Grandview Blvd, W875, Waukesha, WI 53188===Search for more papers by this authorJohn E. Lorbiecki
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorR. Scott Hinks
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorKevin F. King
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorCorresponding Author
Kevin M. Koch
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
GE Healthcare, Applied Science Laboratory, 3200 N. Grandview Blvd, W875, Waukesha, WI 53188===Search for more papers by this authorJohn E. Lorbiecki
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorR. Scott Hinks
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorKevin F. King
Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin
Search for more papers by this authorAbstract
Metallic implants used in bone and joint arthroplasty induce severe spatial perturbations to the B0 magnetic field used for high-field clinical magnetic resonance. These perturbations distort slice-selection and frequency encoding processes applied in conventional two-dimensional MRI techniques and hinder the diagnosis of complications from arthroplasty. Here, a method is presented whereby multiple three-dimensional fast-spin-echo images are collected using discrete offsets in RF transmission and reception frequency. It is demonstrated that this multi acquisition variable-resonance image combination technique can be used to generate a composite image that is devoid of slice-plane distortion and possesses greatly reduced distortions in the readout direction, even in the immediate vicinity of metallic implants. Magn Reson Med 61:381–390, 2009. © 2009 Wiley-Liss, Inc.
REFERENCES
- 1 Kurtz S,Mowat F,Ong K,Chan N,Lau E,Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 2005; 87: 1487–1497.
- 2 Kurtz S,Mowat F,Ong K,Chan N,Lau E,Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89: 780–785.
- 3 Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop 1999; 363: 135–150.
- 4 Schmalzried TP. Wear in total hip and knee replacements. J Bone Joint Surg Am 1999; 81: 115–136.
- 5 Gallo J,Kaminek P,Ticha V,Rihakova P,Ditmar R. Particle disease, a comprehensive theory of peroprosthetic osteolysis: A review. Biomed Pap 2002; 146: 21–28.
- 6 Lavernia CJ. Cost-effectiveness of early surgical intervention in silent osteolysis. J Arthroplasty 1998; 13: 277–279.
- 7 Potter HG,Nestor BJ,Sofka CM,Ho ST,Peters LE,Salvati EA. Magnetic resonance imaging after total hip arthroplasty: evaluation of perioprosthetic soft tissue. J Bone Joint Surg Am 2004; 86: 1947–1954.
- 8 Puri L,Wixson RL,Stern SH,Kohli J,Hendrix RW,Stulberg SD. Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am 2002; 84: 609–614.
- 9 White LM,Kim JK,Mehta M,Merchant N,Schweitzer ME,Morrison WB,Hutchison CR,Gross AE. Complications of total hip arthroplasty: MR imaging–initial experience. Radiology 2000; 215: 254–262.
- 10 Shellock FG. Magnetic resonance safety update 2002: Implants and devices. J Magn Reson Imag 2002; 16: 485–496.
- 11 Park YS,Hwang SK,Choy WS,Kim YS,Moon YW,Lim SJ. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am 2006; 88: 780–787.
- 12 Graf H,Lauer UA,Berger A,Schick F. RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study. Magn Reson Imag 2005; 23: 493–499.
- 13 Graf H,Steidle G,Martirosian P,Lauer UA,Schick F. Effects on MRI due to altered RF polarization near conductive implants or instruments. Med Phys 2006; 33: 124–127.
- 14 Ramos-Cabrer P,van Duynhoven JPM,van der Toor A,Nicolay K. MRI of hip prostheses using single-point methods: In vitro studies towards the artifact free imaging of individuals with metal implants. Magn Reson Imag 2004; 22: 1097–1103.
- 15 Venook RD,Matter NI,Ramachandran M,Ungersma SE,Gold GE,Giori NJ,Macovski A,Scott GC,Conolly SM. Prepolarized magnetic resonance imaging around metal orthopedic implants. Magn Reson Med 2006; 56: 177–186.
- 16
Butts K,Pauly JM,Daniel BL,Kee S,Norbash AM.
Management of biopsy needle artifacts: Techniques for RF-refocused MRI.
J Magn Reson Imag
1999;
9:
586–595.
10.1002/(SICI)1522-2586(199904)9:4<586::AID-JMRI13>3.0.CO;2-X CAS PubMed Web of Science® Google Scholar
- 17 Butts K,Pauly JM,Gold GE. Reduction of blurring in view angle tilting MRI. Magn Reson Med 2005; 53: 418–424.
- 18 Lu W,Pauly KB,Gold GE,Pauly JM,Hargreaves BA. Towards Artifact-free MRI near metallic implants. In Proceedings of 16th Annual Meeting of the ISMRM, Toronto, ON, Canada, 2008. p 838.
- 19 Koch KM,Rothman DL,de Graaf RA. Optimization of static magnetic field homogeneity in the human and animal Brain In Vivo. Progr NMR Spectrosc Forthcoming, doi:10.1016/j.pnmrs.2008.04.001.
- 20 Kolind SH,MacKay AL,Munk PL,Ziang Q. Quantitative evaluation of metal artifact reduction techniques. J Magn Reson Imag 2004; 20: 487–495.
- 21 Koch KM,Hinks RS. Empirical and computed B0 perturbations induced by metallic implants. In Proceedings of 16th Annual Meeting of the ISMRM, Toronto, ON, Canada, 2008. p 1180.
- 22 Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996; 23: 815–850.
- 23 Pauly JM,Le-Roux P,Nishimura D,Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm. IEEE Trans Med Imag 1991; 10: 53–65.
- 24 Beatty PJ,Hargreaves BA,Gurney PT,Nishimura DG. A method for non-Cartesian parallel imaging reconstruction with improved calibration. In Proceedings of 14th Annual Meeting of the ISMRM, Seattle, WA, USA, 2006. p 2462.
- 25 Brau AC,Beatty PJ,Skare S,Bammer R. Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 2008; 59: 382–395.
- 26 Candes E,Romberg J,Tao T. Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 2006; 52: 489–509.
- 27 Donoho D. Compressed sensing. IEEE Trans Inf Theory 2006; 52: 1289–1306.
- 28 Lustig M,Donoho D,Pauly JM. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182–1195.
- 29 King KF. Combining compressed sensing and parallel imaging. In Proceedings of 16th Annual Meeting of the ISMRM, Toronto, ON, Canada, 2008. p 1488.
- 30 Wolf SD,Balaban RS. Magnetization contrast (MTC) and tissue water proton relaxation in vivo. Magn Reson Med 1989; 10: 135–144.