Volume 57, Issue 3 pp. 606-613
Note

Whole-heart cine MRI using real-time respiratory self-gating

Sergio Uribe

Sergio Uribe

Center for Medical Image Computing, University College London, London, UK

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
Vivek Muthurangu

Vivek Muthurangu

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
Redha Boubertakh

Redha Boubertakh

Center for Medical Image Computing, University College London, London, UK

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
Tobias Schaeffter

Tobias Schaeffter

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
Reza Razavi

Reza Razavi

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
Derek L.G. Hill

Corresponding Author

Derek L.G. Hill

Center for Medical Image Computing, University College London, London, UK

Center for Medical Image Computing, New Engineering Building, University College London, Malet Place, London WC1E 6BT, UK===Search for more papers by this author
Michael S. Hansen

Michael S. Hansen

Center for Medical Image Computing, University College London, London, UK

Cardiac MR Research Group, Division of Imaging Sciences, King's College London, London, UK

Search for more papers by this author
First published: 26 February 2007
Citations: 114

Abstract

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods, even those that use undersampling techniques, involve breath-holding for periods that are too long for many patients. Free-breathing respiratory gating sequences represent a possible solution for realizing 3D cine imaging. A real-time respiratory self-gating technique for whole-heart cine MRI is presented. The technique enables assessment of cardiac anatomy and function with minimum planning or patient cooperation. Nonangulated isotropic 3D data were acquired from five healthy volunteers and then reformatted into 2D clinical views. The respiratory self-gating technique is shown to improve image quality in free-breathing scanning. In addition, ventricular volumetric data obtained using the 3D approach were comparable to those acquired with the conventional multislice 2D approach. Magn Reson Med 57:606–613, 2007. © 2007 Wiley-Liss, Inc.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.