Development of a rotational cell-seeding system for tubularized extracellular matrix (ECM) scaffolds in vascular surgery
Corresponding Author
A. Callanan
Institute for Materials and Processes, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JL, UK
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Correspondence to: A. Callanan (e-mail: [email protected])Search for more papers by this authorN.F. Davis
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorT. M. McGloughlin
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorM. T. Walsh
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorCorresponding Author
A. Callanan
Institute for Materials and Processes, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JL, UK
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Correspondence to: A. Callanan (e-mail: [email protected])Search for more papers by this authorN.F. Davis
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorT. M. McGloughlin
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorM. T. Walsh
Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
Search for more papers by this authorAbstract
Tubularized porcine extracellular matrices (ECMs) are under investigation as adjuvant scaffolds for endovascular aneurismal repair (EVAR). Limitations with tubularized ECMs in this setting include difficulties in achieving a confluent endothelium on the scaffold's luminal surface prior to in vivo implantation. In this in vitro study a rotational “cell-seeding rig” (RCR) was constructed to assess the potential for endothelialization of tubular ECM constructs. Human aortic endothelial cells (HAECs) were cultured onto the luminal surfaces of tubular porcine urinary bladder matrix (UBM) scaffolds and rotated in the RCR at experimental rotational speeds. Results showed that endothelial attachment occurred at a rotation speed of six revolutions per hour. HAECs continued to proliferate after the initial attachment period of 24 h and formed a confluent endothelial monolayer after 14 days of growth. Our results demonstrate that RCRs facilitate attachment of HAECs in vitro at a speed of six revolutions per hour. The endothelialization technique presented in the current study may be important for advancing tissue-engineering approaches to address some of the current limitations in endovascular treatments of abdominal aortic aneurysms. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 781–788, 2014.
References
- 1Sakalihasan N, Limet R, Defawe OD. Abdominal aortic aneurysm. Lancet 2005; 365: 1577–1589.
- 2Vorp DA, Vande Geest JP. Biomechanical determinants of abdominal aortic aneurysm rupture. Arterioscler Thromb Vasc Biol 2005; 25: 1558–1566.
- 3Callanan A, Morris LG, McGloughlin TM. Finite element and photoelastic modelling of an abdominal aortic aneurysm: A comparative study. Comput Methods Biomech Biomed Eng 2012; 15: 1111–1119.
- 4Kamineni R, Heuser RR. Abdominal aortic aneurysm: A review of endoluminal treatment. J Interv Cardiol 2004; 17: 437–445.
- 5Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991; 5: 491–499.
- 6Egelhoff CJ, Budwig RS, Elger DF, Khraishi TA, Johansen KH. Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions. J Biomech 1999; 32: 1319–1329.
- 7Davis NF, McGuire BB, Callanan A, Flood HD, McGloughlin TM. Xenogenic extracellular matrices as potential biomaterials for interposition grafting in urological surgery. J Urol 2010; 184: 2246–2253.
- 8Callanan A, Davis NF, Walsh MT, McGloughlin TM. Mechanical characterisation of unidirectional and cross-directional multilayered urinary bladder matrix (UBM) scaffolds. Med Eng Phys 2012; 34: 1368–1374.
- 9Shaikh FM, O'Brien TP, Callanan A, Kavanagh EG, Burke PE, Grace PA, McGloughlin TM. New pulsatile hydrostatic pressure bioreactor for vascular tissue-engineered constructs. Artif Organs 2010; 34: 153–158.
- 10Badylak SF. Xenogeneic extracellular matrix as a scaffold for tissue reconstruction. Transpl Immunol 2004; 12: 367–377.
- 11Badylak SF, Weiss DJ, Caplan A, Macchiarini P. Engineered whole organs and complex tissues. Lancet 2012; 379: 943–952.
- 12Callanan A, Davis NF, Walsh MT, McGloughlin TM. Tissue-engineered extracellular matrices (ECMs) as adjuvant scaffolds for endovascular aneurysmal repair (EVAR). In: D Eberli, editor. Regenerative Medicine and Tissue Engineering: Cells and Biomaterials. InTech; 2011: 301–322.
- 13Ishii S, Sato M, Sonomura T, Yamada K, Tanihata H, Ishikawa H, Terada M, Sahara S, Kawai N, Kimura M, Mori I. Optimal covering material for stent-grafts placed in the portal vein in a canine model. Cardiovasc Intervent Radiol 2005; 28: 624–631.
- 14Nakata M, Pavcnik D, Uchida BT, VanAlstine W, Timmermans HA, Toyota N, Terada M, Brountzos E, Kaufman JA, Keller FS, Rosch J. Comparison of small intestinal submucosa-covered and noncovered nitinol stents with PTFE endografts in injured ovine femoral arteries: A pilot study. Cardiovasc Intervent Radiol 2003; 26: 459–467.
- 15Niyyati M, Petersen BD, Pavcnik D, Uchida BT, Timmermans HA, Hiraki T, Wu RH, Brountzos E, Keller FS, Rösch J. A flexible stent with small intestinal submucosa covering for direct intrahepatic portocaval shunt: Experimental pilot study in swine. Cardiovasc Intervent Radiol 2005; 28: 215–220.
- 16Yamada K, Pavcnik D, Uchida BT, Timmermans HA, Corless CL, Yin Q, Yamakado K, Park JW, Rösch J, Keller FS, Sato M, Yamada R. Endoluminal treatment of ruptured abdominal aortic aneurysm with small intestinal submucosa sandwich endografts: A pilot study in sheep. Cardiovasc Intervent Radiol 2001; 24: 99–105.
- 17Deutsch M, Meinhart J, Vesely M, Fischlein T, Groscurth P, von Oppell U, Zilla P. In vitro endothelialization of expanded polytetrafluoroethylene grafts: A clinical case report after 41 months of implantation. J Vasc Surg 1997; 25: 757–763.
- 18Zilla P, Preiss P, Groscurth P, Rösemeier F, Deutsch M, Odell J, Heidinger C, Fasol R, von Oppell U. In vitro-lined endothelium: Initial integrity and ultrastructural events. Surgery 1994; 116: 524–534.
- 19Deutsch M, Meinhart J, Zilla P, Howanietz N, Gorlitzer M, Froeschl A, Stuempflen A, Bezuidenhout D, Grabenwoeger M. Long-term experience in autologous in vitro endothelialization of infrainguinal ePTFE grafts. J Vasc Surg 2009; 49: 352–362; discussion 362.
- 20Brown B, Lindberg K, Reing J, Stolz DB, Badylak SF. The basement membrane component of biologic scaffolds derived from extracellular matrix. Tissue Eng 2006; 12: 519–526.
- 21Rosario DJ, Reilly GC, Ali Salah E, Glover M, Bullock AJ, Macneil S. Decellularization and sterilization of porcine urinary bladder matrix for tissue engineering in the lower urinary tract. Regen Med 2008; 3: 145–156.
- 22Badylak SF, Vorp DA, Spievack AR, Simmons-Byrd A, Hanke J, Freytes DO, Thapa A, Gilbert TW, Nieponice A. Esophageal reconstruction with ECM and muscle tissue in a dog model. J Surg Res 2005; 128: 87–97.
- 23Livak KJ, Schmittgen TD. Analysis of relative gene expression data using real-time quantitative PCR and the 2(-Delta Delta C(T)) Method. Methods 2001; 25: 402–408.
- 24Engbers-Buijtenhuijs P, Buttafoco L, Poot AA, Dijkstra PJ, de Vos RA, Sterk LM, Geelkerken RH, Vermes I, Feijen J. Biological characterisation of vascular grafts cultured in a bioreactor. Biomaterials 2006; 27: 2390–2397.
- 25Dartsch PC, Hammerle H. Orientation response of arterial smooth muscle cells to mechanical stimulation. Eur J Cell Biol 1986; 41: 339–346.
- 26Engelmayr GC, Jr, Soletti L, Vigmostad SC, Budilarto SG, Federspiel WJ, Chandran KB, Vorp DA, Sacks MS. A novel flex-stretch-flow bioreactor for the study of engineered heart valve tissue mechanobiology. Ann Biomed Eng 2008; 36: 700–712.
- 27Buttafoco L, Engbers-Buijtenhuijs P, Poot AA, Dijkstra PJ, Daamen WF, van Kuppevelt TH, Vermes I, Feijen J. First steps towards tissue engineering of small-diameter blood vessels: Preparation of flat scaffolds of collagen and elastin by means of freeze drying. J Biomed Mater Res B Appl Biomater 2006; 77: 357–368.
- 28Nieponice A, McGrath K, Qureshi I, Beckman EJ, Luketich JD, Gilbert TW, Badylak SF. An extracellular matrix scaffold for esophageal stricture prevention after circumferential EMR. Gastrointest Endosc 2009; 69: 289–296.
- 29Boruch AV, Nieponice A, Qureshi IR, Gilbert TW, Badylak SF. Constructive remodeling of biologic scaffolds is dependent on early exposure to physiologic bladder filling in a canine partial cystectomy model. J Surg Res 2010; 161: 217–25.
- 30Badylak SF, Lantz GC, Coffey A, Geddes LA. Small intestinal submucosa as a large diameter vascular graft in the dog. J Surg Res 1989; 47: 74–80.
- 31Jeong SI, Kim SY, Cho SK, Chong MS, Kim KS, Kim H, Lee SB, Lee YM. Tissue-engineered vascular grafts composed of marine collagen and PLGA fibers using pulsatile perfusion bioreactors. Biomaterials 2007; 28: 1115–1122.
- 32Davis NF, Callanan A, McGuire BB, Flood HD, McGloughlin TM. Evaluation of viability and proliferative activity of human urothelial cells cultured onto xenogenic tissue-engineered extracellular matrices. Urology 2011; 77: 1007 e1–1007 e 7.
- 33Opitz F, Schenke-Layland K, Cohnert TU, Starcher B, Halbhuber KJ, Martin DP, Stock UA. Tissue engineering of aortic tissue: Dire consequence of suboptimal elastic fiber synthesis in vivo. Cardiovasc Res 2004; 63: 719–730.
- 34Nasseri BA, Pomerantseva I, Kaazempur-Mofrad MR, Sutherland FW, Perry T, Ochoa E, Thompson CA, Mayer JE Jr, Oesterle SN, Vacanti JP. Dynamic rotational seeding and cell culture system for vascular tube formation. Tissue Eng 2003; 9: 291–299.
- 35Batra J, Robinson J, Soares AS, Fields AP, Radisky DC, Radisky ES. Matrix metalloproteinase-10 (MMP-10) interaction with tissue inhibitors of metalloproteinases TIMP-1 and TIMP-2: Binding studies and crystal structure. J Biol Chem 2012; 287: 15935–15946.
- 36Sutcliffe MC, Davidson JM. Effect of static stretching on elastin production by porcine aortic smooth muscle cells. Matrix 1990; 10: 148–153.