Volume 16, Issue 9 pp. 851-864
Article
Full Access

Effect of the design variables on the energy performance and size parameters of a heat transformer based on the system acetone/H2/2-propanol

L. M. Gandia

L. M. Gandia

División de Investigacón y Recursos del Ente Vasco de la Energia, San Vicente 8, 48001 Bilbao, Spain

Grupo de Ingenieria Quimica. Departamento de Quimica Aplicado. Facultad de Quimica de San Sebastian. Universidad del Pais Vasco Apartado 1072, 20080 San Sebastian, Spain

Search for more papers by this author
M. Montes

M. Montes

División de Investigacón y Recursos del Ente Vasco de la Energia, San Vicente 8, 48001 Bilbao, Spain

Grupo de Ingenieria Quimica. Departamento de Quimica Aplicado. Facultad de Quimica de San Sebastian. Universidad del Pais Vasco Apartado 1072, 20080 San Sebastian, Spain

Search for more papers by this author
First published: December 1992
Citations: 24

Abstract

A high-temperature chemical heat pump based on the system acetone/H2/2-propanol for waste heat recovery was studied. Two reversible catalytic chemical reactions are involved in this system. The waste heat (at 333–353 K) is recovered by means of the endothermic liquid-phase dehydrogenation of 2-propanol, and is upgraded at high temperature (453–473 K) by the reverse reaction, the exothermic gaseous-phase hydrogenation of acetone. In this process, a fraction of the recovered waste heat is removed at low temperature (303 K), to carry out the separation by vapour rectification between acetone and 2-propanol.

A mathematical model was developed, that permits the study of the effect of the heat pump operating conditions on the energetic performance (COP), exergetic efficiency and size parameters. Also, this model allows the estimation the optimal range for the system control variables. Under these conditions, the energy and size parameters have been calculated on a basis of 0.32 MW upgraded heat.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.